PAGE 5 OF 27
0621 IH-3838
TO ACTIVATE UNIT
1. Pull on door to
activate unit.
Alarm will sound
for 30 seconds
to alert that the
unit is activated.
(See Figure 24)
CAUTION!
Once seal is
broken, the
flow cannot
be stopped.
2. Place eyes in fluid
flow, keeping eyes
open (use fingers
to keep eyelids
open if necessary).
If it is difficult to do
so, get someone
to assist.
(See Figure 25)
NOTE: If desired, head can be positioned on
headrest for comfort or arms can be placed
on the sides of the station.
3. Wash eyes for the
duration of flow.
Alarm will sound
at the end of 15
minutes to alert
that immediate
medical
assistance should
be sought.
(See Figure 26)
NOTE: Waste reservoir will begin to lower
from bottom of the unit. This will continue to
lower until all fluid has been used. Following
15 minute flush, seek immediate medical
attention.
INSTALLATION CONTINUED
ARMING UNIT CONTINUED
5. Slide nozzle onto
nozzle compartment,
making sure the tube
is not twisted.
(See Figure 19)
6. Push headrest back to its original position until an
audible click is heard. (See Figure 20)
7. Close door. A click will be heard confirming the
nozzle is engaged and the alarm is reactivated.
(See Figure 21)
CAUTION! The
station is now
armed and will
activate if door
is opened.
8. Place tamper-evident
seal over the door
and front face of the
unit. (See Figure 22)
CAUTION! The
area under the
unit must be
kept clear at all
times to allow the
waste reservoir
to drop during
use of the system.
Failure to drop
will cause the
eyewash station
to malfunction in
an emergency.
(See Figure 23)
Figure 19
Figure 20
Figure 22
Figure 21
Figure 23
OPERATION
Figure 24
Figure 25
Figure 26
Tamper-
evident
Seal
Keep This
Area Clear
30-Second
Alarm
Headrest
Armrest