background image

02/2005

3

www.U-LineService.com

WH95TP, BI95BTP and BCM95 Ice Makers

General Precautions

Use this appliance for its intended purpose only and 
follow these general precautions along with those listed 
throughout this guide:

WARNING

SHOCK HAZARD — Electrical Grounding Required. 

• Keep the unit unplugged throughout installation 

except during testing.

• Never remove the round grounding prong from 

the plug and never use a two-prong grounding 
adapter.

• Never use an extension cord to connect power to 

the unit.

• Always keep your working area dry. 

CAUTION

• Use care when moving and handling the unit. Use 

gloves to prevent personal injury from sharp edges.

• Do not lift the unit by the door or door handle.

• Do not install the unit behind closed doors or in any 

way that would obstruct airflow to the front grille, 
which may cause the unit to malfunction.

You have received a carton containing your WH95TP, 
BI95BTP or BCM95 Ice Maker with a package inside 
containing a User Manual, a Product Registration Card 
and water connection parts. Complete and mail the 
Product Registration Card or register online at www.U-
LineService.com. Once your unit is installed, keep the User 
Manual and this Installation Guide in a safe place for 
future reference.

WH95TP units are available in vinyl clad cabinets with 
matching doors which have a metal door frame and 
handle, a travel pin to secure closure and are reversible. 
1/4-inch thick panel not available for this model.

BI95BTP units are available in vinyl clad cabinets with 
matching doors which have a slightly contoured handle 
across the top, a travel pin to secure closure and are 
reversible. The doors have recessed front panels that will 
accept a custom 1/4-inch thick door panel.

BCM95 units are available in vinyl clad cabinets with doors 
that have a black glass panel, a handle across the top, a 
travel pin to secure closure and are reversible. 1/4-inch 
thick panel not available for this model.

Please carefully follow the directions that apply to your 
unit and your intended design.

Tools/Materials Required

• Screwdrivers — slotted and Phillips head

• 1/4-inch OD copper tubing and shut-off valve for water 

supply line

• 1/4-inch thick door panel material and cutting tools 

(item only needed if 1/4-inch panel will be used)

Inspection

Unwrap and inspect the unit on a flat, level surface 
capable of supporting its entire weight.

Exterior Cleaning

(As Required)

Black and White Models:

Black and white surfaces may be cleaned with a mild 
detergent and warm water solution. Do not use solvent-
based or abrasive cleaners. Use a soft sponge and rinse 
with clean water. Wipe with a soft, clean towel to prevent 
water spotting.

2 Inspect and Plan

Summary of Contents for BCM-95

Page 1: ...0300 FAX 414 354 7905 Service Parts Tech Lines Phone 800 779 2547 FAX 414 354 5696 OnlineService U Line com 2005 U Line Corporation 02 2005 WH95TP BI95BTP and BCM95 Ice Makers for Marine or Recreatio...

Page 2: ...e water supply Improper hook up can result in substantial property damage If you are unsure of your ability to safely connect the water supply to the unit consult a licensed plumber for assistance Thi...

Page 3: ...H95TP units are available in vinyl clad cabinets with matching doors which have a metal door frame and handle a travel pin to secure closure and are reversible 1 4 inch thick panel not available for t...

Page 4: ...ludes the door handle and water line connection see Figure 2 IMPORTANT It is extremely important that the unit sits on a level surface as it does not have feet levelers If it is not level the ice mold...

Page 5: ...binet Figure 7 Note that there may be a nut behind one or both screws on either side 5 Install hinge on opposite side bottom of cabinet See Figure 8 Replace nut on back side where installed Align hing...

Page 6: ...Make sure travel pin in door engages the closer in the assembly then tighten screws on travel pin assembly securely See Figure 13 Other Site Requirements Power Supply The unit requires a grounded and...

Page 7: ...not weigh more than 20 lbs Door Panel Installation Install the insert as follows CAUTION Use care when handling the insert Insert edges may be sharp 1 Remove top hinge screw pin with a Phillips head s...

Page 8: ...must observe all state and local codes All water connections MUST BE made by a licensed qualified plumbing contractor Failure to follow recommendations and instructions may result in damage and or ha...

Page 9: ...area see Figure 20 This will also safeguard against kinking the line 5 Go on to 7 Prepare Power Supply Electrical Specifications CAUTION Electrical installation must observe all state and local codes...

Page 10: ...eling from front to back and side to side Make any necessary adjustments The unit s top surface should be approximately 1 8 below the countertop 5 Secure the flange to the frame structure using the fo...

Page 11: ...setting adjustments should be necessary at this time For information about Adjusting the Temperature Control see the User Manual As soon as the ice maker mold reaches the proper temperature the ice m...

Page 12: ...t appear to be flowing into unit Solution A Check that the water is connected and turned on and the line is not obstructed Water coming into the unit may take an hour or more Problem Q The cubes produ...

Reviews: