![U-Line 3018CLR SERIES Use And Care Manual Download Page 14](http://html2.mh-extra.com/html/u-line/3018clr-series/3018clr-series_use-and-care-manual_3140375014.webp)
Use & Care Guide
11
Ice Machines
5. Re-install the standpipe into the water trough.
6. Clean the Interior Bin as follows:
• Dilute one packet of CLR cleaner into two quarts of water.
• Using a sponge or cloth, clean interior of ice bin, tubing and
door. This cleaner will remove all mineral deposits and other
contaminants from the surfaces.
• Using a bottle brush, clean out the trough drain tube and pump
tubing where needed.
7. Turn unit on by touching POWER
.
8. Place unit in cleaning mode by activation through the Customer
Menu. See PRODUCT OPERATION for more detail.
9. When water begins flowing over the evaporator (approximately 3
minutes), pour 1 packet of CLR cleaner into the water trough. The
cleaning process will last approximately 45 minutes.
10. Dilute 1 tablespoon bleach in 1 gallon of warm water. Apply this
solution to the entire inside of the storage area. Then rinse
thoroughly with water.
The unit will resume operation approximately 15 minutes after the
automated cleaning process is completed. The water fill valve will
energize, fill the water reservoir, and shut-off after three minutes.
The compressor begins to operate and water flows over the
evaporator assembly (ice mold). Initially, the water flow may not be
uniform, causing uneven sized cubes or water to spill into the ice
storage bin. This is a normal situation that will correct itself within
the first 24 hours of operation.
Standpipe
Evaporator
Water trough
Brush