![U-Line 3018CLR SERIES Use And Care Manual Download Page 12](http://html2.mh-extra.com/html/u-line/3018clr-series/3018clr-series_use-and-care-manual_3140375012.webp)
Use & Care Guide
9
Ice Machines
Door Alignment and Adjustment
Align and adjust the door if it is not level, or is not sealing properly. If
the door is not sealed the unit may not cool properly, or excessive
frost or condensation may form in the interior.
NOTICE
Properly aligned, the door’s gasket should be firmly in
contact with the cabinet all the way around the door (no
gaps). Carefully examine the door’s gasket to assure that it is
firmly in contact with the cabinet. Also make sure the door
gasket is not pinched on the hinge side of the door.
CAUTION
!
• Do not attempt to use the door to raise or pivot your unit.
This would put excessive stress on the hinge system.
• Pay special attention to the Cable Arm. Make sure not to
over extend or damage it during door alignment.
Stainless Models (Removing Wrap)
1. Open door completely.
2. Using a Phillips screwdriver, remove the two wrap screws from the
bottom of the stainless steel door wrap.
3. Gently pull bottom of wrap away from door.
4. The wrap hinges on top of the door. Carefully pull wrap away and
then up
. See below.
5. Remove cable from display by pressing
in the release tab on the cable
connector.
Alignment and Adjustment
1. Using a T-25 Torx Bit, loosen each
pair of torx head screws on both the
upper and lower hinge plate.
2. Square and align door as necessary.
3. Tighten Torx head screws on hinge.
4. Re-connect display and re-install stainless steel wrap.
5 3000 Series Doors
Wrap Screws
Cable Arm
Step 1
Step 2
Door Top
Door Bottom
Press Tab Down
T-25 Torx Screw
T-25 Torx Screw