OPERATING ISSUE
RECOMMENDATIONS
No power to machine
Check power cord is connected to both machine and outlet.
Check main power switch is on.
Check power fuse.
No display after power on
Check power fuse.
Display shown but machine will not start.
Contact Uline Customer Service at 1-800-295-5510.
Bad film seal
Check film type selection.
Turn off machine, check belt/blade position.
Check sealing units are closed and locked.
Check if film roll shaft is in the right position.
Replace belts and blades.
Adjust the temperature.
Film seal is stretched.
Check film type selection.
Check if film roll shaft is in the right position.
Adjust the temperature.
Adjust the air flow.
Check if film roll shaft is jammed.
Film does not run through.
Check if sealing units are closed and locked.
Check blade placement.
Replace belts and blades.
Air cushions do not hold air.
Film roll is loaded the wrong way.
Check belt/blade position.
Check if film roll shaft is in the right position.
Check if sealing units are closed and locked.
Film jams occur frequently.
Check film causing blockage.
Check belts and blades. Replace as needed.
Check film and mandrel settings.
Remove and reload film into machine to ensure film is not
jamming up injector.
Film blockage
Check if film roll shaft is jammed.
Remove any film causing blockage.
Check film run on machine.
Film winding around rollers
Remove any film causing blockage.
TROUBLESHOOTING