background image

ODIN-W2 series - System Integration Manual 

UBX-14040040 - R03

 

Advance Information 

Design-in 

 

 

Page 15 of 33

 

2.2.1

 

Antenna connectors 

This  section provides an overview of the different antenna options for the external antenna connectors. The 
main antenna connector port is mandatory while  the MIMO antenna connector is optional and used only in 
MIMO applications. 

 

Figure 4:  ODIN-W260 with connectors for external antennas 

 
The sections below list  the antennas that are included in the radio type approvals of the module. For each 
antenna,  the "Approvals" field defines in which test reports the antenna is included.  Definitions of the 
«Approvals» field are: 

 

FCC - The antenna is included in the FCC test reports and thus approved for use in countries that accept 
the FCC radio approvals, primarily US. 

 

IC  -  The antenna is included in the IC (Industrie Canada) test reports and thus approved for use in 
countries that accept the IC radio approvals, primarily Canada. 

 

R&TTE - The antenna is included in the R&TTE test reports and thus approved for use in countries that 
accept the R&TTE radio approvals, primarily the European countries. 

 

MIC - The antenna is included in the Japanese government affiliated MIC test reports and thus approved 
for use in the Japanese market. 

In general, antennas with SMD connection, Reverse Polarity SMA connector or U.FL connector are included in 
FCC, IC, R&TTE and MIC radio tests. The antennas with SMA connector are included in R&TTE and MIC radio 
tests but not in FCC or IC due to FCC/IC regulations. 
The external antennas are connected to the board through U.FL connectors. Some of the antennas are 
connected directly to the U.FL connector of the board and some are connected using an SMA or reversed 
polarity SMA connector through a short U.FL to SMA or reversed polarity SMA adapter cable.  Antenna 
accessories and recommended antennas can be found in Appendix B. 

2.2.2

 

Internal antenna design 

Keep a minimum clearance of 5 mm between the antenna and the casing. Keep a minimum 10 mm free space 
from metal around the antenna including under. If a metal enclosure is required, ODIN-W260 with antenna 
connectors has to be used.  
It is recommended to place the ODIN-W262 module so that the internal antenna is in the corner of the host PCB 
(Pin A18 should be in the corner) as seen  in  Figure  5.  The antenna side (short side closest to the antenna), 

Summary of Contents for ODIN-W260

Page 1: ...is document describes the system integration of ODIN W2 series multiradio module The ODIN W2 module is a compact stand alone Wi Fi IEEE 802 11 2012 a b g n dual band 2x2 MIMO Bluetooth v2 1 EDR Blueto...

Page 2: ...name Type number Firmware version PCN IN reference ODIN W260 ODIN W260 00B 00 1 0 0 TBD ODIN W262 ODIN W262 00B 00 1 0 0 TBD u blox reserves all rights to this document and the information contained h...

Page 3: ...ower saving modes 10 1 6 3 System input and output signals 10 1 6 4 Restoring default configuration 10 1 6 5 Firmware update 11 1 7 Antenna interfaces 11 1 7 1 Antenna connectors 11 1 7 2 Internal ant...

Page 4: ...ing 22 3 3 6 Wave soldering 22 3 3 7 Hand soldering 22 3 3 8 Rework 23 3 3 9 Conformal coating 23 3 3 10 Casting 23 3 3 11 Grounding metal covers 23 3 3 12 Use of ultrasonic processes 23 4 Qualificati...

Page 5: ...factor The module is complete with embedded driver stack and application for wireless data transfer and AT command configuration The upcoming extensions of the module firmware include micro Access Poi...

Page 6: ...nly one port is active at any given point of time The Wi Fi MIMO port is separate from the other ports and connected directly to a coaxial U FL connector through a band pass filter The U FL connector...

Page 7: ...s stable 1 3 Pin description Figure 2 ODIN W2 series pin assignment The signals are available on castellation pads on the edge of the PCB The unfilled circular pads are GND pads Black circular pads ar...

Page 8: ...C16 LPO_CLK I Low Power Oscillator clock input The modules require an external 32 768 kHz clock for low power modes Should be left unconnected if not used UART A13 UART_RXD I UART Receive A11 UART_TX...

Page 9: ...odule has VCC supplied The same voltage domain is used internally to supply the generic digital interfaces of the modules The V_INT supply output can be used instead of an external discrete regulator...

Page 10: ...and UART DTR signals are used to detect or indicate the status See ODIN W2 AT Commands Manual 1 for more information about the modes Table 4 describes the default setup of the System IOs RED GREEN an...

Page 11: ...GHz single band Wi Fi The use of multiple antennas at both the transmitter and receiver improves communication performance The MIMO technology significantly increases data throughput A MIMO m x n sys...

Page 12: ...pending on the selected host The selected hardware setup must be verified on the application board to guarantee operation RMII The ODIN W2 series module includes a full RMII either for Ethernet MAC to...

Page 13: ...GND pads are available GND pads and the PCB edge castellations Mainly for power supply return path and RF ground Heat dissipation GND pads under the module Mainly used for dissipation of heat especia...

Page 14: ...on the supply pins according to the respective datasheet Do not apply loads which might exceed the limit for maximum available current from V_INT supply see the ODIN W2 series Data Sheet 2 as this ca...

Page 15: ...rovals primarily the European countries MIC The antenna is included in the Japanese government affiliated MIC test reports and thus approved for use in the Japanese market In general antennas with SMD...

Page 16: ...ic interference that affects the module analog parts and performance of RF circuits The heat dissipation during continuous transmission at maximum power can significantly raise the temperature of the...

Page 17: ...high levels The following two preventive steps are implemented in the ODIN W2 series module to control heating Disable Enable MIMO When the die temperature exceeds high threshold 103 C device will sw...

Page 18: ...ed to a 3 3V application A 3 3V 1 8 level converter Texas Instrument TXS0108E between the 3 3V application processor and the 1 8 V ODIN W2 UART Interface The level converter is an 8 bit bidirectional...

Page 19: ...ODIN W2 series System Integration Manual UBX 14040040 R03 Advance Information Design in Page 19 of 33 Figure 7 A complete ODIN W2 design in a 3 3 V application...

Page 20: ...lectronics all conductive materials are grounded workers are grounded and charge build up on ESD sensitive electronics is prevented International standards are used to define typical EPA and can be ob...

Page 21: ...and balls Residual humidity will be dried out Note that this preheat phase will not replace prior baking procedures Temperature rise rate maximum 3 C s If the temperature rise is too rapid in the preh...

Page 22: ...t Cleaning with alcohol or other organic solvents can result in soldering flux residues flooding into the two housing areas that are not accessible for post wash inspections The solvent will also dama...

Page 23: ...If casting is required use viscose or another type of silicon pottant The OEM is strongly advised to qualify such processes in combination with the modules before implementing this in the production C...

Page 24: ...nformation stage as mentioned in the Document status section For an end product using the product cB 0965 there must be a label containing at least the following information This device contains FCC I...

Page 25: ...st the ODIN W2 module be affixed with a label with the Giteki marking below In this case is it recommended that the product is marked with Contains MIC ID R 204 510009 the product be affixed with a la...

Page 26: ...stitute of Electrical and Electronics Engineers I2C Inter Integrated Circuit L Low LDO Low Drop Out LPO Low Power Oscillator MCU Microcontroller MIMO Multi Input Multi Output N A Not Applicable O Outp...

Page 27: ...ble loss must be above the minimum cable loss to meet the regulatory requirements Comment The SMA connector can be mounted in a panel Approval R TTE MIC Name U FL to Reverse Polarity SMA adapter cable...

Page 28: ...ertical Gain 2 0 dBi Size 12 0 x 28 0 mm Cable length 100 mm Connector U FL connector Comment To be mounted on the U FL connector on the PCB Approval FCC IC R TTE and MIC Ex IT 2400 RP SMA 70 002 Manu...

Page 29: ...on the U FL connector on the PCB Approval FCC IC R TTE and MIC FlatWhip 2400 Manufacture r ProAnt Gain 3 0 dBi Size 50 0 x 30 0 mm Connector SMA plug inner thread and pin Comment To be mounted on the...

Page 30: ...403 100 Manufacture r ProAnt Gain 3 0 dBi Size 24x22x1 mm with mounting hole Cable length 100 mm Connector U FL connector Comment Dual band 2 4GHz 5GHz antenna to be mounted on the U FL connector on t...

Page 31: ...y within operating conditions if applied 7 Check UART signal direction 8 Provide proper precautions for ESD immunity as required on the application board Table 6 Schematic checklist Layout checklist N...

Page 32: ...4039949 3 u blox Package Information Guide document number UBX 14001652 For regular updates to u blox documentation and to receive product change notifications register on our homepage http www u blox...

Page 33: ...one 65 6734 3811 E mail info_ap u blox com Support support_ap u blox com Regional Office Australia Phone 61 2 8448 2016 E mail info_anz u blox com Support support_ap u blox com Regional Office China B...

Reviews: