Figure 34: RF input trace
The RF_IN trace on the top layer should be referenced to a suitable ground layer.
4.7.4.2 VCC pad
The VCC pad for the NEO-D9C QZSS correction service receiver needs to have as low an impedance
as possible with large vias to the lower power layer of the PCB. The VCC pad needs a large pad and
the decoupling capacitor must be placed as close as possible. This is shown in the figure below.
Figure 35: VCC pad