Mode 3 : UTC enhanced mode commands list
Command
Code description
Function description
(hex)
ESC u ACR
1B 75 41 [ data x 20] 0D upper line display
ESC u BCR
1B 75 42 [ data x 20] 0D bottom line display
ESC u DCR
1B 75 44 [ data x 20] 0D upper line message scroll
continuously
ESC u ECR
1B 75 45 hh ':' mm 0D
display time
h,m='0'-'9'
ESC u FCR
1B 75 46 [ data x 20] 0D upper line message scroll
once pass
ESC u HCR
1B 75 48 n m 0D
change attention code
20h<=n,m
ESC u ICR
1B 75 49 [ data x 40] 0D two line display
ESC RS CR
1B 0F 0D
change to UTC standard
mode
Mode 4 : AEDEX mode commands list
Command Code description
Function description
(hex)
! # 1CR
21 23 31 [ data x 20] 0D upper line display
! # 2CR
21 23 32 [ data x 20] 0D bottom line display
! # 4CR
21 23 34 [ data x 20] 0D upper line message scroll
continuously
! # 5CR
21 23 35 hh ':' mm 0D display time
h,m='0'-'9'
! # 6CR
21 23 36 [ data x 20] 0D upper line message scroll
once pass
! # 8CR
21 23 38 n m 0D
change attention code
20h<=n,m
! # 9CR
21 23 39 [ data x 40] 0D two line display
! # ACR
21 23 41 [ data x 20] 0D upper line scroll message
! # BCR
21 23 42 [ data x 20] 0D bottom line display message
Mode 5 : ICD 2002 mode commands list
Command Code
Function description
description
(hex)
HT
09
move cursor right
(only valid in overwrite mode)
BS
08
move cursor left
(only valid in overwrite mode)
CR
0D
move cursor to left-most position
(only valid in overwrite mode)
ESC @
1B 40
initialize customer display to initial
state, clears display buffer, set display
mode to shift and sets current display
row to upper row
ESC U
1B 55
select upper row as current row
(initial default)
ESC D
1B 44
select lower row as current row
ESC A z
1B 41 z
sets customer display disable or
enable
z
'D'=disable,
'E'=enable
ESC C r c
1B 43 r c
move cursor to specified position
(only valid in overwrite mode)
-r
Row
( 'U'=upper,'D'=lower)
-c
Column number
(range from 1~20)
ESC E r z
1B 45 r z
set special effect or display mode of
specified row