21
‐
2.3.5
TELEPHONE
NUMBERS
ARC1
to
ARC4
–
these
are
the
Alarm
Receiving
Centre
(control
centre)
telephone
numbers.
Enter
#026
;
the
unit
will
announce
“
Telephone
Number
1
”,
enter
the
telephone
number
(max
16
digits)
followed
by
#
.
Repeat
for
alternative
ARC
telephone
numbers
2,
3
&
4.
PR1
to
PR4
–
these
are
the
Personal
Recipient
(relative/friend)
telephone
numbers.
Enter
#030
;
the
unit
will
announce
“
Telephone
Number
5
”,
enter
the
telephone
number
(max
16
digits)
followed
by
#
.
Repeat
for
alternative
PR
telephone
numbers
6,
7
&
8.
If
PR
telephone
numbers
are
used
a
“unit
identity
message”
should
be
recorded
–
see
section
2.3.10.
Note:
to
DELETE
individual
telephone
numbers
enter
the
Parameter
Number
followed
by
#
.
Example;
to
delete
ARC3
enter
#028#.
2.3.6
ACTIVITY
MONITORING
The
activity
monitoring
mode
allows
the
Reach
to
monitor
resident’s
movement
over
a
12
or
24
hour
period
and
automatically
report
an
alarm
at
the
end
of
the
period
if
there
has
been
no
activity
(or
less
activity
than
the
minimum
threshold).
The
activity
threshold
can
range
from
0
to
9
–
this
is
the
minimum
number
of
PIR
activations
you
would
expect
to
see
during
the
activity
monitoring
period.
Enable/Disable
–
a
PIR
movement
detector
(hardwired
or
radio)
must
be
fitted
if
activity
monitoring
is
being
enabled.
Enter
#034
;
the
unit
will
announce
“
Activity
Monitoring
”,
press
0
to
Disable
or
1
to
Enable
followed
by
#
.
12/24
Hours/Threshold
–
set
the
activity
monitoring
period
as
12
or
24
hours
and
the
threshold
count
0
to
9.
Enter
#035
;
the
unit
will
announce
“
Activity
Monitoring
Period
”,
enter
a
2
digit
number,
the
first
digit
being
0
for
12
hours
or
1
for
24
hours,
the
second
digit
being
the
0
‐
9
threshold
followed
by
#
.
Example;
12
hours
with
a
threshold
of
2
=
02
(enter
#035
02#)
or
24
hours
with
a
threshold
of
6
=
16
(enter
#035
16#).
2.3.7
PERIODIC
TEST
The
Reach
has
the
option
to
perform
an
automatic
test
call
on
a
preset
interval
between
1
and
99
days.
The
time
the
test
call
is
made
is
the
time
the
feature
is
enabled
or
the
same
time
plus
12
hours.
For
example
if
it
is
enabled
at
11AM
you
could
set
the
test
call
to
be
11PM
if
desired.
Note:
the
user
will
not
know
when
a
test
call
is
being
performed,
the
dial
‐
out
is
silent
and
speech
is
not
heard.
Periodic
Test
–
set
with
a
4
digit
code.
Enter
#036
;
the
unit
will
announce
“
Periodic
Test
”,
the
first
2
digits
is
the
interval
between
calls
(01
to
99),
the
3
rd
digit
is
to
enable/disable
the
feature
(0
to
disable
or
1
to
enable)
and
the
4
th
digit
is
to
choose
the
time
(0
=
current
time
or
1
=
+12
hours)
followed
by
#
.
Example;
to
enable
a
periodic
test
every
14
days
at
the
current
time
enter
#036