6.

 

HOW

 

TO

 

SWITCH

 

ON/OFF

 

 

Once

 

the

 

power

 

lead

 

is

 

plugged

 

in

 

and

 

switched

 

on

 

the

 

display

 

will

 

flash

 

Press

 

ENTER

 

for

 

Setup

”.

 

Press

 

the

 

ENTER

 

key

 

and

 

the

 

Main

 

Menu

 

will

 

be

 

displayed.

 

The

 

battery

 

symbol

 

should

 

be

 

flashing

 

in

 

the

 

top

 

of

 

the

 

Main

 

Menu

 

display

 

to

 

indicate

 

the

 

battery

 

is

 

being

 

charged.

 

After

 

20

 

seconds

 

the

 

display

 

will

 

go

 

blank,

 

the

 

unit

 

is

 

still

 

on

 

but

 

the

 

display

 

goes

 

off

 

to

 

save

 

power.

 

 

The

 

Sensor

 

Controller

 

should

 

be

 

left

 

plugged

 

in

 

and

 

switched

 

on

 

at

 

all

 

times

 ‐ 

this

 

will

 

ensure

 

its

 

battery

 

is

 

always

 

fully

 

charged

 

and

 

alarms

 

will

 

always

 

be

 

transmitted.

  

 

TO

 

SWITCH

 

OFF

  

 

Switch

 

the

 

mains

 

supply

 

OFF

 

and

 

unplug

 

power

 

lead.

 

Press

 

the

 

ENTER

 

key

 

to

 

display

 

the

 

Main

 

Menu.

 

Press

 

the

 

T

 

key

 

to

 

select

 

„

 

Power

 

Off

 

ƒ

 

then

 

press

 

ENTER

.

 

The

 

display

 

will

 

show

 

The

 

Controller

 

is

 

Powering

 

Down

 

before

 

switching

 

off.

 

 
 

7.

 

LOW

 

BATTERY

 

WARNING

 

 

If

 

the

 

mains

 

power

 

fails

 

the

 

Sensor

 

Controller

 

will

 

continue

 

to

 

operate

 

from

 

its

 

battery.

 

The

 

length

 

of

 

time

 

the

 

Sensor

 

Controller

 

will

 

operate

 

for

 

on

 

battery

 

alone

 

will

 

depend

 

on

 

usage.

 

 

When

 

the

 

battery

 

is

 

running

 

low

 

the

 

unit

 

will

 

beep

2

 

and

 

display

 

Sending

 

a

 

Low

 

Battery

 

Alarm

”.

  

When

 

the

 

battery

 

is

 

exhausted

 

the

 

unit

 

will

 

display

 

 

Low

 

Battery

 

 

Controller

 

is

 

Powering

 

Down

  

before

 

turning

 

itself

 

off.

  

When

 

the

 

mains

 

power

 

is

 

restored

 

it

 

will

 

need

 

at

 

least

 

8

 

hours

 

to

 

fully

 

recharge

 

the

 

battery.

   

 

2

 

The

 

low

 

battery

 

beep

 

can

 

be

 

disabled

 

in

 

programming.

 

 

Detailed

 

information

 

on

 

battery

 

management

 

for

 

all

 

Tynetec

 

products

 

is

 

available

 

in

 

a

 

separate

 

document.

 

Contact

 

Tynetec’s

 

customer

 

support

 

dept

 

and

 

request

 

a

 

copy

 

of

 

Doc

 

No.

 

FM0630.

  

 
 

8.

 

NAVIGATING

 

THE

 

DISPLAY

 

MENUS

 

 

Press

 

the

 

ENTER

 

key

 

once

 

and

 

the

 

display

 

will

 

illuminate.

 

Use

 

the

 

ST

 

keys

 

to

 

scroll

 

up/down

 

through

 

the

 

options.

 

The

 

cd

 

arrows

 

in

 

the

 

top

 

right

 

of

 

the

 

display

 

indicate

 

more

 

menu

 

options

 

are

 

available

 

using

 

the

 

up/down

 

keys.

 

 

Main Menu   V1.05A                

d

 

„

 

Quick Setup 

ƒ

 

 

Advanced Setup 

 

 

Power Off 

 

 

Scroll

 

down

 

past

 

„

 

Power

 

Off

 

ƒ

 

and

 

the

 

display

 

will

 

show;

 

 

Main Menu   V1.05A                

c

 

„

 

Exit 

ƒ

 

 

 

 

 

 

 

 

The

 

menu

 

option

 

highlighted

 

„

 

in

 

arrows

 

ƒ

 

can

 

be

 

selected

 

with

 

the

 

ENTER

 

key.

 

This

 

will

 

either

 

take

 

you

 

to

 

another

 

sub

menu

 

or

 

give

 

you

 

the

 

option

 

to

 

change

 

settings.

  

 

Use

 

the

 

ST

 

keys

 

to

 

increase/decrease

 

the

 

setting

 

highlighted

 

by

 

the

 

cursor.

 

Use

 

the

 

W

 

X

 

keys

 

to

 

move

 

the

 

cursor

 

back/forwards

 

between

 

fields.

  

To

 

return

 

to

 

the

 

Main

 

Menu

 

at

 

any

 

time

 

press

 

the

 

S

 

&

 

X

 

keys

 

together.

 

To

 

exit

 

the

 

Main

 

Menu

 

select

 

„

 

Exit

 

ƒ

 

and

 

press

 

the

 

ENTER

 

key,

 

the

 

display

 

will

 

blank.

 

 

 

9.

 

QUICK

 

SETUP

 

MODE

 

 

Select

 

„

 

Quick

 

Setup

 

ƒ

 

from

 

the

 

Main

 

Menu

 

and

 

press

 

the

 

ENTER

 

key,

 

the

 

display

 

will

 

show;

  

 

Would  you  like  to  set 

  

W

 

the  date  and  time ? 

  

X

 

 

 

 

         

yes = enter, next = 

W

 

X

 

 

Press

 

ENTER

 

and

 

the

 

display

 

will

 

change

 

to

 

Enter

 

Date

  

(use

 

DD/MM/YY

 

format).

 

Use

 

the

 

ST

 

keys

 

to

 

set

 

the

 

Date

 

(DD)

 

then

 

press

 

X

  

Use

 

the

 

ST

 

keys

 

to

 

set

 

the

 

Month

 

(MM)

 

then

 

press

 

X

  

Use

 

the

 

ST

 

keys

 

to

 

set

 

the

 

Year

 

(YY)

 

then

 

press

 

ENTER

 

and

 

the

 

display

 

will

 

change

 

to

 

Enter

 

Day

 

Use

 

the

 

ST

 

keys

 

to

 

set

 

the

 

Day

 

then

 

press

 

ENTER

 

and

 

the

 

display

 

will

 

change

 

to

 

Enter

 

Time

 

(24

 

hour

 

format).

 

Use

 

the

 

ST

 

keys

 

to

 

set

 

the

 

Hour

 

(HH)

 

then

 

press

 

X

  

Use

 

the

 

ST

 

keys

 

to

 

set

 

the

 

Minutes

 

(MM)

 

then

 

press

 

ENTER

 

and

 

the

 

display

 

will

 

change

 

to

 

Auto

 

BST

 

Use

 

the

 

ST

 

keys

 

to

 

set

 

Auto

 

BST

 

On

 

or

 

Off

 

then

 

press

 

ENTER

 

(

On

 

means

 

the

 

British

 

Summer

 

Time

 

+/

‐ 

1

 

hour

 

adjustments

 

will

 

be

 

made

 

automatically

 

every

 

March/October).

 

The

 

display

 

will

 

go

 

back

 

to

 

the

 

set

 

date

 

and

 

time

 

menu,

 

press

 

the

 

X

 

key

 

to

 

move

 

to

 

the

 

next

 

option;

 

 

Would  you  like  to  set 

 

W

 

the  sensor  type ? 

  

X

 

 

 

 

         

yes = enter, next = 

W

 

X

 

 

Press

 

the

 

ENTER

 

key

 

and

 

the

 

display

 

will

 

change

 

to

 

 

Set

 

Sensor

 

Type;

  

Bed

  

Use

 

the

 

ST

 

keys

 

to

 

select

 

from;

 

Bed

 

or

 

Chair

 

or

 

Aux

  

(Aux

 

=

 

pressure

 

mat

 

or

 

door

 

contact)

 

then

 

press

 

ENTER

.

 

The

 

display

 

will

 

go

 

back

 

to

 

the

 

set

 

sensor

 

type

 

menu,

 

press

 

the

 

X

 

key

 

to

 

move

 

to

 

the

 

next

 

option;

 

 

Would  you  like  to  set 

 

W

 

the  on/off  times ? 

  

X

 

 

 

 

         

yes = enter, next = 

W

 

X

 

 

Press

 

the

 

ENTER

 

key

 

and

 

the

 

display

 

will

 

change

 

to

 

 

On

 

All

 

The

 

Time

 

?

  

No

 

Choose

 

if

 

you

 

want

 

the

 

bed/chair

 

monitored

 

all

 

the

 

time

 

or

 

during

 

preset

 

periods

 

each

 

day.

 

Use

 

the

 

ST

 

keys

 

to

 

choose

 

Yes

 

or

 

No

 

then

 

press

 

ENTER

.

 

If

 

you

 

choose

 

No

 

the

 

display

 

will

 

change

 

to

  

Enter

 

Start

 

Time

 

1

  

00:00

 

(24HR

 

format).

 

Use

 

the

 

ST

 

keys

 

to

 

set

 

the

 

Hour

 

then

 

press

 

X

  

Use

 

the

 

ST

 

keys

 

to

 

set

 

the

 

Minutes

 

then

 

press

 

ENTER

 

and

 

the

 

display

 

will

 

change

 

to

 

Enter

 

Stop

 

Time

 

1

  

00:00

 

 

Summary of Contents for Altec 169MHz

Page 1: ...o their bed chair If the person does not return and an alarm is raised but they are OK then an optional 1 to 99 minute programmable reset period can be set If the person is not detected back in their...

Page 2: ...er includes a power lead and a rechargeable battery depending on the package chosen either a bed sensor a chair sensor a pressure mat or a door contact will also be supplied 1 The sensor controller sh...

Page 3: ...azard Plug the lead into the Sensor Controller Chair Sensor with 2m Lead Tynetec P No ZCS859 Dimensions 325mm x 130mm x 10mm LxWxD RJ45 Double Adapter used to connect 2 chair sensors Tynetec P No P102...

Page 4: ...rrows can be selected with the ENTER key This will either take you to another sub menu or give you the option to change settings Use the ST keys to increase decrease the setting highlighted by the cur...

Page 5: ...o choose Yes or No then press ENTER If you choose No the monitoring will end at the end of the monitoring period If you choose Yes the display will change to Still in Bed Alarm How Long 000 Mins Use t...

Page 6: ...e and Test d Calibrate Sensor View In Out States Change Sensitivity Calibrate and Test c Test Mode Exit Calibrate Sensor place the bed chair sensor in position and press ENTER to learn the un occupied...

Page 7: ...ensor On all the time No Active start stop time periods all 00 00 disabled Instant alarm Yes Delay before Alarm No Not in Bed Alarm No Still in Bed Alarm No Low Battery Beep Yes Radiplugs disabled X10...

Page 8: ...ach announces Trigger Radio Device and the front light starts flashing GREEN 2 Press the CARER CALL button the Reach will announce the Sensor Type 3 Press the GREEN button to exit the learn mode 4 Che...

Page 9: ...d to send a CARER CALL Press this key once and the display will show Unit is sending a CARER CALL alarm PLEASE WAIT After about 10 seconds the display will blank You will hear reassurance tones from t...

Reviews: