DESCRIPTION OF TRACTOR CONTROLS
2
2 - 1
3. OPERATINg METHOD
1) Operating principles : For DPF regeneration, the exhaust gas temperature is increased by increasing the engine
back pressure.
Operation sequence
Step
Regeneration Alarm
DPF Lamp On
DPF Regeneration
Engine Max.RPM
Regeneration Button Press
(more than 3 sec.)
Electronic Exhaust Valve Operation
Regeneration Complete
DPF Lamp Off
T474NH-영문-02(나).indd 15
2019-06-14 오전 9:49:54
Stop the tractor in open place.
Apply the parking brake lever.
Set the all levers in neutral position.
Increase engine RPM over 2,850.
Check coolant temperature over 60'C.
Press DPF generation button to s
tart
DPF regeneration process.
Wait until DPF regeneration process
is finished.