2
Positioning the heater - normal installation
!
DANGER! More than one heater can be installed in
the same sauna cabin.
Position the sauna heater:
• on the same wall as the door (or the side wall if very close to
the door wall). The heater can also be positioned in a recess
(see
Figure 3,
Page 2).
• at a safe distance from the floor, side walls and interior fittings
(see
Figure 2,
Page 2).
1
3
6
5
7
4
2
Figure 2:
Positioning the heater - normal installation
1.
Minimum distance from side wall: 110 mm
2.
Minimum distance from ceiling: 1030 mm
3.
Minimum distance from interior fittings: 100 mm
4.
Minimum ceiling height: 1900 mm
5.
Minimum distance: 20 mm
6.
Minimum distance from interior fittings: 30 mm
7.
Distance from floor: 100-270 mm (with legs: 100 mm)
Positioning the heater - recess installation
Position the heater at a safe distance from the floor, side walls
and interior fittings (see
Figure 3,
Page 2).
4
7
6
8
2
1
1
5
3
Figure 3:
Positioning the heater - recess installation
1.
Minimum distance from side wall: 200 mm
2.
Max. 1000 mm
3.
Minimum distance from ceiling: 1030 mm
4.
Minimum distance from interior fittings: 100 mm
5.
Minimum ceiling height: 1900 mm
6.
Minimum distance: 20 mm
7.
Minimum distance from interior fittings: 30 mm
8.
Distance from floor: 100-270 mm (with legs: 100 mm)
Positioning the inlet vent
Install the inlet vent straight through the wall under the centreline
of the heater. Vent size for a family sauna approx. 125 cm².
The air circulation from the door must concord with the hot air cir-
culation from the heater.
Summary of Contents for SENSE SPORT
Page 2: ...1311 SVENSKA INSTALLATIONSANVISNING SENSE SPORT 29005175 SVE ...
Page 11: ......
Page 12: ...1311 ENGLISH INSTALLATION GUIDE SENSE SPORT 29005175 ENG ...
Page 21: ......
Page 22: ...1311 DEUTSCH INSTALLATIONSANLEITUNG SENSE SPORT 29005175 TYS ...
Page 31: ......
Page 32: ...1311 FRANÇAIS NOTICE D INSTALLATION SENSE SPORT 29005175 FRA ...
Page 41: ......
Page 42: ...1311 РУССКИЙ ИНСТРУКЦИИ ПО УСТАНОВКЕ SENSE SPORT 29005175 RYS ...
Page 51: ......
Page 52: ...1311 POLSKI INSTRUKCJA INSTALACJI SENSE SPORT 29005175 PL ...
Page 61: ......
Page 62: ...1311 NEDERLANDS INSTALLATIEHANDLEIDING SENSE SPORT 29005175 NLD ...
Page 71: ......