2018-01-02
2900 5262
SENSE COMBI PURE Quick-Start Tip Sheet
This page to be used in conjuction with Tylo Full Manual included
CONNECTION/WIRING DIAGRAM
TAB
208 V 1 Phase
240 V 1 Phase
Model
Amperage
Amps
Output
kW
Wire Size
AWG
Amperage
Amps
Output
kW
Wire Size
AWG
Sense Combi-U 7
26
5
.
3
10
30
7
.
0
8
Sense Combi-U 8
30
6
.
3
8
35
8
.
3
8
Note
: Heating elements do not change for voltage changes. The heater output will change
based on the voltage applied to heater. Most North American homes are 240v.
10
14
15
6
12
13
11
14
RJ10 4P4C
3 x 14 AWG
RJ10 4P4C
RJ10 4P4C
RJ10 4P4C
max 300 feet - Combi Pure
***
B
B
41
40
1 2
6
7
8
9
3 4
5
120 V~
14 AWG
Max. 6 Amp.
5
.
3-8
.
3 kW
208/240 V~
G
Connect Control cable to
jack 9 on circuit board.
Connect NTC Sensor cable
to jack 1 on circuit board.
Sensor Installation Tip
Sensor with metal tab can usually installed without cov-
er with one screw through the sensor tab directly to the
¿QLVKHGZDOO
If using Sensor Cover
, you must feed the sensor wire
through the sensor holder FIRST before putting sensor
wire in the wall.
Figure 19: Wiring diagram
1.
NTC Sensor -
Combi Pure.
2.
Ext switch (External switch Optional)
3.
Door jumper pre-installed in terminal #3.
(Door con
t
act not required for N America)
4.-8
. N/A
9.
Pure
Control
10. Heater
11. Terminal for connection of electrical cable
12. Control panel (connect to position 9)
13. Sensor - Combi Pure (connect to NTC
terminal #
1)
14. Light/terminal for connection of light
.
(requires separate 120v supply)
15.
Door Contact
not required for N America
16. External switch (option)
In order for control
to operate light, a
separate 120V supply
must be provided and
connected to heater
Field Connect three
copper conectors
x3