2
Position the sensor according the picture (see Figure 3).
1
7
10
9
8
11
6
4
3
2
3
5
3
To prevent build up of lime-scale and high-
er salt/mineral levels, empty the reservoir
after each use. If this is not done and
water is added each time you take a sau-
na, foam build-up could occur which can
cause the level sensor to detect a higher
water level than usual. There is a risk the
heating element may break.
18.5 mm
7-5/16"
49 mm
19-5/16 "
462 mm
24-3/8 "
28 mm
11"
43 mm
17 "
4 mm
1-9/16 "
Fig 14: Fitting the cover for the
water reservoir, herb grille and
IUDJUDQFHKROGHUDLUKXPLGL¿HU
1.
Minimum distance from side wall: 4” (10 mm)
2.
Sensor position alt 1: 3” (7.5 mm) from heater
3.
Sensor
4.
Sensor position alt 2: 3” (7.5 mm) from heater front
5.
Sensor position: 1” (2.5 mm) from ceiling
6.
Minimum distance from ceiling: 44” (110 mm)
7.
Minimum distance from heater guard: 4” (10 mm)
8.
Minimum ceiling height: 75” (1900 mm)
9.
Minimum distance: 1” (2.5 mm)
10. Minimum distance from heater guard: 2” (5 mm)
11.
'LVWDQFHIURPÀRRU´PP
** Combi Pure Control distance to heater is max 300 feet
1
2
Figure 9: Resetting the temperature cut-out
1. Temperature cut-out water reservoir
2. Temperature cut-out sauna heater
Pure Control Installation Instructions
The control panel can be installed inside or outside the sauna room. If the control is installed inside the room, install no higher than 3’
FPDERYHWKHÀRRU1RFORVHUWKDQ´FPWRKHDWHU
Installation Without Mounting Bracket (Typical)
Cut a 1-3/16” (3 cm) hole through the wall big enough for the control panel connector.
Attach the double-sided adhesive to the control panel. Before applying the control to the wall, connect it to the heater and electrically
WHVWHYHU\WKLQJ¿UVW&OHDQWKHVXUIDFHZKHUHWKHFRQWUROZLOOEHDSSOLHGWRUHPRYHDOOGXVW5HPRYHWKHSURWHFWLYHEDFNLQJIURPWKH
adhesive. Silicone sealant can be applied in the groove on the back of the panel as an extra seal. Connect the control wire, push the
H[FHVVZLUHWKURXJKWKHKROHLQWKHZDOODQGSUHVVWKHFRQWUROSDQHO¿UPO\WRWKHZDOO
Installation Bracket
Use the mounting bracket as a template to mark screws holes on the wall. Tighten the screws a little until the bracket is nearly secured.
Remove the bracket from the wall. Use adhesive to mount the control to the bracket. Remember to position the switch according to the
picture.
Install without bracket
Control stuck directly to
the wall. Control cable
in the stud cavity.
Installation without Bracket (Typical)
Installation with Bracket
Install with bracket
Generally only used when control
wire is surface mounted; i.e. sold
log style outdoor sauna.
Positioning the control panel
The control panel can be installed inside or
outside of the sauna room. (Outside is Typical)