background image

Control panel instructions: 

 

Main current:

 

Press 

POWER

 to turn the sauna 

ON (AN) 

or 

OFF (AUS). 

If a red

 

light comes on the sauna 

is

 ON

. If it is white the sauna is 

OFF. 

 

Timer functions:

 

Press and hold down 

 or 

 in order to set the running time. You can 

also run your finger up or down the timer to set it.  

Timer 2: 

Use this function with a pre-setting of up to 24 hours to set the sauna to come on later. 

 

Temperature functions: 

1. Press to switch between 

C

 and 

F

. C or F will light up to show the required units.  

 
2. Press and hold 

 or 

 to set the required temperature.  

Pressing once will increase or reduce the setting in one degree intervals. You can also run your finger 

over the temperature bar. 

 

The central temperature display shows the actual sauna temperature. 

 

3. Press to set the 

bench/ leg/ floor heat to

 

ON 

or 

OFF. 

Red waves can be seen in heating mode 

and white ones in 

OFF

 mode. 

Light functions

:

 

 

1. Press Inside light to switch it 

ON 

or 

OFF

2. Note: Outside light 

ON 

or 

OFF 

will not work with S series models. 

Colour therapy functions: 

Press the colour therapy light in order to activate coloured light or a colour sequence. The sequence 

is shown in detail below: 

1.  Press – RED 

2.  Press – RED-GREEN 

3.  Press – GREEN 

4.  Press – BLUE-GREEN 

5.  Press – BLUE 

 

  

  

  

  

 

Page 10 

 

Summary of Contents for Prime+ 1814

Page 1: ...commissioning 2 Pre assembly information 2 Electrical requirements 2 Cabin construction assembly 3 Junction box connections 3 Main junction box connections 5 Power connections on the ceiling 7 Contro...

Page 2: ...less if you start shaking if you have a headache or feel sick or nauseous People who suffer from hyperthermia or cardiovascular diseases should seek medical advice before using the infrared sauna Do n...

Page 3: ...ted correctly There are 12 power connection junction boxes that are labelled accordingly and must be connected after assembling each section Back wall panel Left Right Bench valance Bench B1 to B1 L1...

Page 4: ...ection is at the front of the sauna Note Put the ceiling bench valance and bench aside until the corresponding steps Rear wall panel 2 sections Place the left back wall panel section into the left han...

Page 5: ...ide wall panel sections Slide the fan component Box1 into the retaining device on the bench valance Connect the white connector on the black junction box to the white connector on the fan Secure both...

Page 6: ...olt alternating current cable into the socket yet Bench Push the bench seat down onto the right and left wall panel Tilt the bench against the back panel as shown below Connect the S 1 electrical conn...

Page 7: ...electrical connections are placed through the ceiling and are not disconnected when you put the ceiling into position slowly Tip To make it easier to pull cables through the ceiling slot you can take...

Page 8: ...g to the rear wall panel 2 connections Lift the door panel at the top left of the rear external face of the ceiling You will see 4 connections labelled 1 4 Fix each ceiling connection 1 4 to the corre...

Page 9: ...De luxe door handles Inside Outside Your infrared sauna is now ready for use Page 9...

Page 10: ...or to set the required temperature Pressing once will increase or reduce the setting in one degree intervals You can also run your finger over the temperature bar The central temperature display shows...

Page 11: ...ting tips a Main control panel lights not lit up Check the electrical connections between the ceiling and the back panel and the front panel Ensure that the plug is correctly connected to the socket a...

Page 12: ...Wiring Diagram Page 12...

Page 13: ...tg rder innan kabinen tas i drift 2 Information om f rmonteringen 2 Elkrav 2 Montera kabinen 3 Anslutningar i f rdelningsl dan 3 Anslutningar i huvudf rdelningsl dan 5 Elanslutningar i taket 7 Instruk...

Page 14: ...huvudv rk blir illam ende eller kr ks Personer som lider av hypertermi eller av hj rt k rlsjukdom b r r dfr ga l kare innan de anv nde infrav rmekabinen Anv nd inte v rmekabinen om du har druckit alk...

Page 15: ...slutnings f rgreningsdosor som r markerade och som ska anslutas efter monteringen av varje del Bakre v gg v nster h ger b nkbekl dnad b nk B1 till B1 L1 till L1 R1 till R1 S3 till S3 S1 till S1 B2 til...

Page 16: ...n r riktade fram t Anm St ll undan tak b nkbekl dnad och b nk tills du kommer till motsvarande steg Bakre v gg 2 element Placera den bakre v ggens v nstra element i det v nstra sp ret Placera den bakr...

Page 17: ...ren i b nkbekl dnaden Anslut den vita kontakten fr n den svarta f rgreningsdosan till fl ktens vita kontakt F st b da bekl dnader Anslutningar Koppla samman alla anslutningar i bekl dnadsomr det Alla...

Page 18: ...ned b nksitsen mot den h gra och v nstra v ggen Tippa b nken mot den bakre v ggen enligt illustreringen nedan Anslut f rgreningsdosan S 1 till f rdelarl dan S 1 S kra S 1 f rdelningsl dans lock med tv...

Page 19: ...v ggarna enligt bilden nedan Anm Se till att elanslutningarna dras genom taket och inte blir kl mda n r ni l ngsamt f r taket p plats Tips F r att g ra det enklare att dra kablar genom taksp ret kan d...

Page 20: ...gg 2 anslutningar ppna d rrpanelen upptill till v nster p takets bakre yttersida H r finns fyra anslutningar som r markerade med siffrorna 1 4 F st respektive takanslutning 1 4 vid motsvarande siffra...

Page 21: ...Deluxe handtag Insida Utsida Nu r infrav rmekabinen klar att anv nda Sidan 9...

Page 22: ...ktionen f r att v xla mellan C och F nskad enhet C eller F ljusmarkeras 2 Tryck ned och h ll eller nedtryckt f r att st lla in nskad temperatur Om du trycker en g ng h js eller s nks den nskade inst l...

Page 23: ...r kan inte spelas upp i USB eller MicroSD uttaget Tips f r att tg rda st rningar a Indikatorerna i huvudkontrollpanelen lyser inte Kontrollera de elektriska anslutningarna mellan tak och bakre v gg sa...

Page 24: ...Kopplingsschema Sidan 12...

Page 25: ...e 2 Informations relatives au pr montage 2 Sp cifications lectriques 2 Installation montage de la cabine 3 Connexions de la bo te de distribution 3 Connexions de la bo te principale de distribution 5...

Page 26: ...maux de t te malaises ou naus es Il est recommand aux personnes souffrant d hyperthermie ou de maladies cardiovasculaires de prendre l avis de leur m decin avant d utiliser la cabine infrarouge Ne pa...

Page 27: ...tage Il y a 12 connexions lectriques bo tes de distribution rep r es de mani re logique chacune d entre elles devra tre raccord e apr s le montage de la partie dont elle rel ve Arri re Gauche Droite A...

Page 28: ...se trouve l avant de la cabine Remarque Mettez de c t le toit l assise de banquette et la banquette jusqu ce que vous en ayez besoin pour le montage Paroi arri re 2 l ments Ins rez la paroi arri re g...

Page 29: ...arton 1 l int rieur du dispositif de retenue de l assise de la banquette Raccordez la connexion blanche de la bo te de distribution noire la connexion blanche du ventilateur Fixez les deux assises Con...

Page 30: ...re la surface de la banquette entre les parois gauche et droite Clipsez la banquette contre la paroi arri re comme indiqu ci dessous Raccordez l alimentation lectrique S 1 la bo te de distribution S 1...

Page 31: ...ues sont bien enfich es dans le toit et ne viennent pas tre d branch es lors de sa mise en place Astuce Pour pouvoir tirer plus facilement le c ble dans la rainure du toit vous pouvez disposer des pet...

Page 32: ...neau de porte situ l ext rieur et l arri re sur la partie sup rieure gauche du toit Vous voyez alors 4 connexions num rot es de 1 4 Raccordez chacune des connexions 1 4 au num ro correspondant et assu...

Page 33: ...Poign es de porte grand standing C t int rieur C t ext rieur Votre cabine chaleur infrarouge est maintenant pr te tre utilis e Page 9...

Page 34: ...a temp rature souhait e La temp rature d finie augmente ou diminue d un degr chaque pression Vous pouvez galement passer votre doigt sur la barre des temp ratures L affichage central des temp ratures...

Page 35: ...ipale ne s allume pas V rifiez les connexions lectriques entre le toit et la paroi arri re ainsi que la paroi avant V rifiez que le connecteur est bien raccord la prise de courant et au commutateur V...

Page 36: ...Sch ma lectrique Page 12...

Page 37: ...chtsma nahmen vor Inbetriebnahme 2 Information zur Vormontage 2 Elektrische Anforderungen 2 Kabinen Aufbau Montage 3 Verteilerkastenanschl sse 3 Hauptverteilerkasten Anschl sse 5 Stromverbindungen an...

Page 38: ...merzen belkeit oder Brechreiz auftreten Personen die unter Hyperthermie oder unter Herz Kreislauf Erkrankungen leiden sollten rztlichen Rat vor dem Einsatz der Infrarot Kabine einholen Nutzen Sie kein...

Page 39: ...12 Stromanschluss Verteilerdosen die entsprechend gekennzeichnet sind und nach der Montage jeden Abschnitts anzuschlie en sind R ckw Links Rechts Banksch rze Bank B1 an B1 L1 an L1 R1 an R1 S3 an S3...

Page 40: ...r die Glas Elemente zur Vorderseite des Raums liegen Anm Stellen Sie Decke Banksch rze und Bank bis zu den entsprechenden Schritten zur Seite R ckwand 2 Elemente Platzieren Sie das linke R ckwand Elem...

Page 41: ...Bauteil Karton 1 in die Haltevorrichtung der Banksch rze gleiten Schlie en Sie den wei en Anschluss der schwarzen Verteilerdose an den wei en Anschluss des Ventilators an Befestigen Sie beide Sch rzen...

Page 42: ...Sie den Banksitz an der rechten und linken Wand hinunter Kippen Sie die Bank wie unten gezeigt gegen die R ckwand Schlie en Sie die elektrische S 1 Verteilerdose an den S 1 Verteilerkasten an Sichern...

Page 43: ...abgeklemmt werden wenn Sie die Decke langsam in Position bringen Tipp Um es leichter zu machen Kabel durch die Deckenschlitze zu ziehen k nnen Sie kleine Styropor Bl cke nehmen und sie an mehrere Ste...

Page 44: ...ke an R ckwand 2 Anschl sse Heben Sie die T rf llung oben links an der hinteren Au enseite der Decke an Sie werden 4 Anschl sse mit der Kennzeichnung 1 4 sehen Befestigen jeden Deckenanschluss 1 4 an...

Page 45: ...Deluxe T rgriffe Innenseite Au enseite Ihre Infrarot W rmekabine ist jetzt einsatzbereit Seite 9...

Page 46: ...cken und halten Sie oder um die gew nschte Temperatur einzustellen Einmaliges Dr cken wird die gew nschte Einstellung in Ein Grad Stufen erh hen oder senken Sie k nnen auch mit dem Finger ber den Temp...

Page 47: ...t beleuchtet Stellen Sie elektrische Anschl sse zwischen Decke und R ckwand sowie Vorderwand sicher Stellen Sie sicher dass der Stecker richtig mit der Steckdose und dem Schalter verbunden ist Stellen...

Page 48: ...Wiring Diagram Seite 12...

Page 49: ...4 Prime 1814 2 2 2 3 3 5 7 10 10 11 12 121210 1...

Page 50: ...37 o o o o 24 2 Phillips 1 Phillips 10 2 3 2...

Page 51: ...230 12 12 12 12 1 12 B1 B1 L1 L1 R1 R1 S3 S3 S1 S1 B2 B2 L2 L2 R2 R2 S4 S4 S2 S2 3 L1 L1 Phillips 2 Phillips 1 3...

Page 52: ...1 8 16 152 230 2 4...

Page 53: ...1 3 3 5...

Page 54: ...2 1 24 3 2 ON OFF ON 3 230 S 1 S 1 S 1 2 Phillips 6...

Page 55: ...4 90 7...

Page 56: ...FM 1 2 3 7 4 FM 2 4 1 4 1 4 2 5 6 7 8 5 8 5 8 8...

Page 57: ...Deluxe 9...

Page 58: ...POWER ON OFF 2 24 1 C F C F 2 3 1 Inside Light 2 Outside Light S 10...

Page 59: ...Color Therapy Light 1 2 3 4 5 6 7 8 7 9 MP3 FM MP3 USB MicroSD Apple MP3 USB MicroSD 4a 11...

Page 60: ...12...

Reviews: