12

SELF-INSPECTION OF THE INSTALLATION

To inspect the installation:
1.  Switch on the main supply to the heater from the distribution 

board.

2.  Check that the control panel lights up.
3.  Start the heater (see User Guide).
4.  Check that all three pipe elements start to heat up (turn red).

Please keep these instructions!
In the event of problems, please contact the retailer where you purchased 
the equipment.
© This publication many not be reproduced, in part or in whole, without 
the written permission of Tylö. Tylö reserves the right to make changes 
to materials, construction and design.

1

2

3

4

5

6

7

8

1

2

3

4

Pin:

1

2

3

4

Pin:

9

10

Description of cabling/modular contacts

Figure 12: Modular contacts, description

1. NTC Sensor
2. Ext switch
3. Door switch
4. SEC/NTC Sensor (option)
5. RS485 control panels
6. RS485 control panels
7. RS485 control panels
8. RS485 control panels
9. Modular plug
10. Modular contact

Table 3: Connecting components in modular contacts (maximum cable area for RJ10: 0.90 mm/0.20 mm², AWG24)

Connection of

Position

Pin

Comment

Temperature sensor (10K ohm)

1

2-3

Must be an NTC model. May also be connected at Position 4.

External switch with no wire indicator 2

3-4

Both constant or impulse deactivation work.

External switch with wire indication

2

2-3-4

12VDC (maximum 40mA). Tylö external switch, 
item number: 9090 8045.

Door contact without alarm for door 
status

3

3-4

Model NO (Normally Open). Tylö door contact, 
item number:
9090 8035.

Door contact with alarm for door 
status

3

2-3-4

12VDC (maximum 40mA)

Combined temperature cut-out/temperature sensor. Only used for certain heater models.

Temperature cut-out 130°

4

1-4

Temperature sensor (10K ohm)

4

2-3

Must be an NTC model.

NOTE! 

Crimp pliers, e.g. shortening wires, 

are needed if changing modular cabling.

Summary of Contents for Air 10

Page 1: ...5230 SVENSKA INSTALLATIONSANVISNING ENGLISH INSTALLATION GUIDE DEUTSCH INSTALLATIONSANLEITUNG FRANÇAIS NOTICE D INSTALLATION РУССКИЙ ИНСТРУКЦИИ ПО УСТАНОВКЕ POLSKI INSTRUKCJA INSTALACJI NEDERLANDS INSTALLATIEHANDLEIDING A ...

Page 2: ...ly with the instructions in this manual Installation tools The following tools and materials are needed for installation and connection water level adjustable spanner screwdrivers Installation planning Before starting to install your sauna heater you should Plan the sauna heater positioning see the Heater positioning normal installation section page 8 Plan the control panel positioning see the att...

Page 3: ... concrete brick etc or of hardened glass the sensor may be installed in the ceiling at a distance from the heater according to Figure 4 1 4 8 11 10 2 6 5 9 7 3 3 Figure 3 Positioning the heater normal installation 1 Minimum distance from the side wall 120 mm 2 Sensor position alt 1 700 mm from the heater 3 Sensor 4 Minimum distance from the back wall 120 mm 5 Sensor position alt 2 700 mm from the ...

Page 4: ... Connect the electrical cable 1 to the terminal 2 see Figure 8 according to the wiring diagram see the Connection wiring diagram section page 11 INSTALLATION Sauna heater installation It is easiest to prepare for installation with the heater lying down To install the heater 1 Lay the heater down with the front facing upwards 2 Undo the screws and open the cover see Figure 7 DANGER The air exhaust ...

Page 5: ...wiring diagram section according to the wiring diagram see the Connection wiring diagram section page 11 6 Connect the light cable if relevant 7 see Figure 8 page 9 to the terminal 8 according to the wiring diagram Figure 11 page 11 7 Close the cover and tighten the screws see Figure 7 page 9 8 Install the sensor on the wall see Figure 9 The thermistor wire may also be passed through the wall Seal...

Page 6: ...ntrol panels 7 RS485 control panels 8 RS485 control panels 9 Heater 10 Terminal for connection of electrical cable 11 Control panel connect to positions 5 8 12 Sensor connect to NTC position 1 13 Lighting terminal for connection of lighting 14 Door contact option 15 External switch option 9 13 14 15 11 12 1 2 3 4 5 6 7 8 11 10 13 RJ10 4P4C 2 x 1 5 mm 2 3 x 1 5 mm 2 RJ10 4P4C RJ10 4P4C RJ10 4P4C B ...

Page 7: ...5 control panels 6 RS485 control panels 7 RS485 control panels 8 RS485 control panels 9 Modular plug 10 Modular contact Table 3 Connecting components in modular contacts maximum cable area for RJ10 0 90 mm 0 20 mm AWG24 Connection of Position Pin Comment Temperature sensor 10K ohm 1 2 3 Must be an NTC model May also be connected at Position 4 External switch with no wire indicator 2 3 4 Both const...

Reviews: