background image

8

Positioning the heater - recess installation

To position the sauna heater in a recess:
1.  Position the heater at a safe distance from the 

fl

 oor, side 

walls and interior 

fi

 ttings (see Figure 5).

2.  Position the sensor according the picture (see Figure 5).

2

3

1

4

5

Figure 2: Schematic diagram of installation

1. Sauna 

heater

2. Control 

panel

3. Sensor
4.  External on/off switch (option, door contact needed for function)
5.  Door contact (option)

Positioning the heater - normal installation

DANGER! No more than one heater may be 
installed in the same sauna cabin.

Position the sauna heater:
• 

on the same wall as the door (or the side wall, if very close 
to the door wall). The heater may also be placed in a recess 
(see Figure 5).

• 

Position the heater at a safe distance from the 

fl

 oor, side 

walls and interior 

fi

 ttings (see Figure 3).

Position the sensor according the picture (see Figure 3).

If the wall on which the sensor is to be installed is made of highly 
heat-absorbing material (e.g. concrete, brick, etc.), or of hardened 
glass, the sensor may be installed in the ceiling at a distance from 
the heater, according to Figure 4.

1

4

8

11

10

2

6

5

9

7

3

3

Figure 3: Positioning the heater - normal installation

1.  Minimum distance from the side wall: 120 mm
2.  Sensor position alt 1: 700 mm from the heater
3. Sensor
4.  Minimum distance from the back wall: 120 mm
5.  Sensor position alt 2: 700 mm from the front of the heater
6.  Sensor position: 200 mm from the ceiling
7.  Minimum distance to the ceiling: 970 mm
8.  Minimum distance to interior 

fi

 ttings: 120 mm

9.  Minimum ceiling height: 1,900 mm
10.  Minimum distance: 20 mm
11.  Minimum distance to interior 

fi

 ttings: 120 mm

Figure 5: Positioning the heater - recess installation

1.  Minimum distance to the side wall: 120 mm
2. Sensor
3.  Max. 1,000 mm
4.  Sensor position: 700 mm from the front of the heater
5.  Sensor position: 200 mm from the ceiling
6.  Minimum distance to the ceiling: 970 mm
7.  Minimum distance to interior 

fi

 ttings: 120 mm

8.  Minimum ceiling height: 1,900 mm
9.  Minimum distance: 20 mm
10.  Minimum distance to interior 

fi

 ttings: 120 mm

Figure 4: Ceiling installation of the sensor

1. 1,200 

mm

1

1

1

3

1

1

4

2

7

10

9

5

8

6

Summary of Contents for Air 10

Page 1: ...5230 SVENSKA INSTALLATIONSANVISNING ENGLISH INSTALLATION GUIDE DEUTSCH INSTALLATIONSANLEITUNG FRANÇAIS NOTICE D INSTALLATION РУССКИЙ ИНСТРУКЦИИ ПО УСТАНОВКЕ POLSKI INSTRUKCJA INSTALACJI NEDERLANDS INSTALLATIEHANDLEIDING A ...

Page 2: ...ly with the instructions in this manual Installation tools The following tools and materials are needed for installation and connection water level adjustable spanner screwdrivers Installation planning Before starting to install your sauna heater you should Plan the sauna heater positioning see the Heater positioning normal installation section page 8 Plan the control panel positioning see the att...

Page 3: ... concrete brick etc or of hardened glass the sensor may be installed in the ceiling at a distance from the heater according to Figure 4 1 4 8 11 10 2 6 5 9 7 3 3 Figure 3 Positioning the heater normal installation 1 Minimum distance from the side wall 120 mm 2 Sensor position alt 1 700 mm from the heater 3 Sensor 4 Minimum distance from the back wall 120 mm 5 Sensor position alt 2 700 mm from the ...

Page 4: ... Connect the electrical cable 1 to the terminal 2 see Figure 8 according to the wiring diagram see the Connection wiring diagram section page 11 INSTALLATION Sauna heater installation It is easiest to prepare for installation with the heater lying down To install the heater 1 Lay the heater down with the front facing upwards 2 Undo the screws and open the cover see Figure 7 DANGER The air exhaust ...

Page 5: ...wiring diagram section according to the wiring diagram see the Connection wiring diagram section page 11 6 Connect the light cable if relevant 7 see Figure 8 page 9 to the terminal 8 according to the wiring diagram Figure 11 page 11 7 Close the cover and tighten the screws see Figure 7 page 9 8 Install the sensor on the wall see Figure 9 The thermistor wire may also be passed through the wall Seal...

Page 6: ...ntrol panels 7 RS485 control panels 8 RS485 control panels 9 Heater 10 Terminal for connection of electrical cable 11 Control panel connect to positions 5 8 12 Sensor connect to NTC position 1 13 Lighting terminal for connection of lighting 14 Door contact option 15 External switch option 9 13 14 15 11 12 1 2 3 4 5 6 7 8 11 10 13 RJ10 4P4C 2 x 1 5 mm 2 3 x 1 5 mm 2 RJ10 4P4C RJ10 4P4C RJ10 4P4C B ...

Page 7: ...5 control panels 6 RS485 control panels 7 RS485 control panels 8 RS485 control panels 9 Modular plug 10 Modular contact Table 3 Connecting components in modular contacts maximum cable area for RJ10 0 90 mm 0 20 mm AWG24 Connection of Position Pin Comment Temperature sensor 10K ohm 1 2 3 Must be an NTC model May also be connected at Position 4 External switch with no wire indicator 2 3 4 Both const...

Reviews: