Positioning the heater - recess installation
To position the sauna heater in a recess:
1. Position the heater at a safe distance from the
fl
oor, side
walls and interior
fi
ttings (see Figure 5).
2. Position the sensor according the picture (see Figure 5).
2
3
1
4
5
Figure 2: Schematic diagram of installation
1. Sauna
heater
2. Control
panel
3. Sensor
4. External on/off switch (option, door contact needed for function)
5. Door contact (option)
Positioning the heater - normal installation
DANGER! No more than one heater may be
installed in the same sauna cabin.
Position the sauna heater:
•
on the same wall as the door (or the side wall, if very close
to the door wall). The heater may also be placed in a recess
(see Figure 5).
•
Position the heater at a safe distance from the
fl
oor, side
walls and interior
fi
ttings (see Figure 3).
Position the sensor according the picture (see Figure 3).
If the wall on which the sensor is to be installed is made of highly
heat-absorbing material (e.g. concrete, brick, etc.), or of hardened
glass, the sensor may be installed in the ceiling at a distance from
the heater, according to Figure 4.
1
4
8
11
10
2
6
5
9
7
3
3
Figure 3: Positioning the heater - normal installation
1. Minimum distance from the side wall: 120 mm
2. Sensor position alt 1: 700 mm from the heater
3. Sensor
4. Minimum distance from the back wall: 120 mm
5. Sensor position alt 2: 700 mm from the front of the heater
6. Sensor position: 200 mm from the ceiling
7. Minimum distance to the ceiling: 970 mm
8. Minimum distance to interior
fi
ttings: 120 mm
9. Minimum ceiling height: 1,900 mm
10. Minimum distance: 20 mm
11. Minimum distance to interior
fi
ttings: 120 mm
Figure 5: Positioning the heater - recess installation
1. Minimum distance to the side wall: 120 mm
2. Sensor
3. Max. 1,000 mm
4. Sensor position: 700 mm from the front of the heater
5. Sensor position: 200 mm from the ceiling
6. Minimum distance to the ceiling: 970 mm
7. Minimum distance to interior
fi
ttings: 120 mm
8. Minimum ceiling height: 1,900 mm
9. Minimum distance: 20 mm
10. Minimum distance to interior
fi
ttings: 120 mm
Figure 4: Ceiling installation of the sensor
1. 1,200
mm
1
1
1
3
1
1
4
2
7
10
9
5
8
6