background image

Under Counter Extreme

34

35

System Setup Method

System Setup Method

2

: ACD pH level up 

(08%, 09%, 10%...)

J

O

G

  D

I A

L

JO

DI

AL

J O

G

 

D

IA

L

or

: ACD pH level down 

(06%, 05%, 04%...)

J

O

G

  D

I A

L

JO

DI

AL

J

O

G

 

D

IA

L

or

Acidic   H Level Adjustment

p

1

Press the setup icon.

2

Press the top left corner of the screen. MENU 
options will fall below upper part of screen.

5

Press“

ACIDIC pH

3

Press desired level.

4

SYSTEM SETUP METHOD

Press“

ALKALI pH

Press desired level.

3

4

1

Press the setup icon.

2

Press the top left corner of the screen. MENU 
options will fall below upper part of screen.

ALKALI pH Level Adjustment

1

: ALK pH level up 

(09%, 10%, 11%...)

5

J

O

G

  D

I A

L

JO

DI

AL

J O

G

 

D

IA

L

or

: ALK pH level down 

(07%, 06%, 05%...)

J

O

G

  D

I A

L

JO

DI

AL

J

O

G

 

D

IA

L

or

Push RETURN icon for previous menu screen. Voice says: “Applied”
Push RETURN icon again to complete set up.
Voice says: “Set up was completed”

Backcolor

Orange highlight shows the current position on the menu.
A blue highlight means that changes to that setting are possible.

Turn the Jog Dial clockwise (or counter-clockwise) to 
select the desired level. Press the PUSH On/Off button 
of the jog dial to make your selection.

When using the Jog Dial

J

O

G

  D

I A

L

JO

DI

AL

J

O

G

 

D

IA

L

If UP/DOWN Icon is pushed, digital number moves by one step.

Turn  the  Jog  Dial  clockwise  (or  counter-  clockwise)  to 
select “

ALKALI pH

”.  Press the PUSH On/Off button of

the jog dial to make your selection.

When using the Jog Dial

J

O

G

  D

I A

L

JO

DI

AL

J

O

G

 

D

IA

L

Push RETURN icon for previous menu screen. Voice says :“Applied” 
Push RETURN icon again to complete set up.
Voice says :“Set up was completed”

Backcolor

Orange highlight shows the current position on the menu.
A blue highlight means that changes to that setting are possible.

Turn the Jog Dial clockwise (or counter-clockwise) to 
select the desired level. Press the PUSH On/Off button 
of the jog dial to make your selection.

When using the Jog Dial

J

O

G

  D

I A

L

JO

DI

AL

J

O

G

 

D

IA

L

If UP/DOWN Icon is pushed, digital number moves by one step.

Turn  the  Jog  Dial  clockwise  (or  counter-  clockwise)  to 
select “

ACIDIC pH

”.  Press the PUSH On/Off button of 

the jog dial to make your selection.

When using the Jog Dial

J

O

G

  D

I A

L

JO

DI

AL

J

O

G

 

D

IA

L

%

50

%

50

ALK 1ST  : 

ALK 2ND :

ALK 3RD :

TURBO   :

ALKALI pH

ACIDIC pH

LANGUAGE

VOLUME

ALK 1ST  : 

ALK 2ND :

ALK 3RD : 

TURBO   :

4

7

10

99

%

%

%

%

4

7

10

99

%

%

%

%

ALKALI pH

ACIDIC pH

LANGUAGE

VOLUME

ACD 1ST : 

ACD 2ND:

ACD 3RD:

25

58

99

%

%

%

ACD 1ST : 

ACD 2ND:

ACD 3RD:

25

58

99

%

%

%

%

50

%

50

Summary of Contents for UCE-E13T

Page 1: ...it must be replaced by the manufacturer or a similarly qualified Tyent repair person in order to avoid a hazard This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowl edge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety C...

Page 2: ...allation Customer Serviceable Parts How to Change the Filters How to Reset the Filter Counters How to use Cleaning Filter Touch Screen Operation Unit Usage pH Level Adjustment System Setup Method Selecting Voice on off Cleaning Function Eco Mode Turbo Function Usage Recommendations Temperature Sensor Unit Specifications Troubleshooting Product Warranty 2 3 4 6 11 12 13 14 18 19 20 22 23 24 25 26 27...

Page 3: ... potential hazard that could result in significant bodily harm or damage to the unit If you see this sign stop the use of this unit ATTENTION Yellow Warning Sign indicates a potential hazard that could result in minor bodily harm or damage to the unit If using groundwater make sure the water meets drinking water compliance standards before installation If not a pre filter may be required source wa...

Page 4: ...as of high humidity and or high temperature new hose This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concern ing use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not pla...

Page 5: ...pH reagents near flame There is a risk of fire Do not poke or scratch the touch pad or LCD display with sharp objects In areas of hard water where calcium scaling is present on faucets notify your service provider and install a cell safe anti scale pre filter to protect the ionizer from scale build up Do not use alkaline or acidic water in fish bowls or aquariums The sudden change in pH could be h...

Page 6: ...f the outlet pipe with a soft brush If you do not clean it regularly scale such as lime components Calcium and Magnesium may occur In areas with high TDS of water calcium can remain the tip of the outlet pipe Please keep it clean Storage If the original packaging is not available then store in a cool dry place where the unit won t be scratched Carefully remove this unit from its packaging Keep the...

Page 7: ...ater Outlet Pipe Drain Pipe Fixing Nut Nozzle Acidic Outlet Alkaline Outlet Front cover Cable Connector Front Sheet Hanging Groove Rear Case Power Cord Water Inflow Door Case Front Case 29 5cm 11 6inch 17 2cm 6 8inch 3 3cm 1 3inch 13 2cm 5 2inch 11cm 4 3inch 16cm 6 3inch 38 2cm 15inch SINK 5cm 2inch a 10 30 50 50 UnderCounterExtreme 1 1 4 2 5 3 4 6 7 8 2 3 Speaker ...

Page 8: ... produce the highly stable electric power required for each phase of electrolysis These Platinum Coated Titanium Plates are made with highly stable durable Solid Mesh Hybrid technology that enhances the instantaneous electrolysis efficiency Changes to the LCD screen and Jog Dial light can be easily identified by color to check each selected phase Operating functions can be further identified by the v...

Page 9: ...S A MUST Customizable Settings System Super Simple Filter Replacement System pH Control Function Respective alkali acid turbo phases can be easily controlled by the user Self Diagnosis Function When the condition of the source water is not suitable the water discharge is automatically suspended displaying a Warning Sign on the screen Filter Usage Indication and Replacement Time Guide SELF MAINTENA...

Page 10: ...re properly installed to the unit The unit and components are subject to change without prior notifi cation in order to enhance performance Shut off both the hot and the cold water main supply at the pipe under the sink Locate the cold water supply line valve Disconnect the faucet s cold water supply line from the main cold water pipe Use a towel to catch the small amount of water that may come fr...

Page 11: ...ttom of the dispenser 1 Press the outflow pipes into the holes of the dispenser upper hole water outlet pipe 152mm 6inches lower hole drain pipe 102mm 4inches Connect each hose from the dispenser to a union connector Connect each hose from the ionizer to the union connector When you connect the hoses please match the hoses by color i e orange orange white white If your tower has hoses that are red ...

Page 12: ...lity or declining water taste Recommended filter replacement cycle Every 6 months Removes harmful chemicals like chlorine compounds such as agrichemicals and detergents large suspended matters like rust and sediments as well as other volatile organic compounds through an efficient activated absorption method It also eliminates bad smells and any remaining dissolved chlorine Secondary Filter 2nd Fi...

Page 13: ... follow this process in order to ensure that your machine functions properly If you do not initialize the filter after replacing the filter the correspond ing filter change message will continue to operate After initializing the reset press the H2O button and run purified water for 3 minutes Filter 1 reset Filter 2 reset 50 50 1 First Filter Reset Press the bottom part of the LCD screen A menu will ap...

Page 14: ...a disposable filter When cleaning the machine with a TYENT CLEANING FILTER be sure to always use the H2O purified water level only do not use any other level while cleaning or damage could occur If the unit was subject to hard water conditions an Anti Scale filter should be connected This filter will prevent scale build up on plates Attention Remove the existing 2nd filter and install the TYENT Cle...

Page 15: ... Push the upper part of LCD Screen MENU Window appears below the upper part of LCD Screen CAUTION 2 DISPLAYS COLORS The backlight of the LCD display will match the pH level color according to the water pH level being used after the icon is pressed Alkaline Water 1 light Blue Color 15 00 Turbo Red Color 05 00 Approx 8 0 pH Alkaline Water 2 Dark Blue Color 15 00 Approx 9 0 pH Alkaline Water 3 Purple...

Page 16: ...e seen well under direct sunlight Do not push the Screen hard with sharp or pointy objects This display means that the water outflow has been stopped prior because of the suspension of water supplied to the unit 15 00 14 39 Unit usage Press the desired icon on the LCD screen 1 The water outflow will start and the screen will display the current level and stop time 2 Press the screen to stop the fl...

Page 17: ... Level 2 Approx 9 0 pH light purple Alkaline Level 3 Approx 9 5 pH purple H2O Approx 7 0 pH Purified Water green Acid Level 1 Approx 6 5 5 5 pH light greenish yellow Acid Level 2 Approx 5 5 4 0 pH light orange Acid Level 3 Approx 4 5 3 5 pH dark orange The pH value indicated for each level is based on standardized test results which have used average tap water p The water level you choose will be ...

Page 18: ...og dial to make your selection When using the Jog Dial J O G D I A L J O G D I A L J O G D I A L If UP DOWN Icon is pushed digital number moves by one step Turn the Jog Dial clockwise or counter clockwise to select ALKALI pH Press the PUSH On Off button of the jog dial to make your selection When using the Jog Dial J O G D I A L J O G D I A L J O G D I A L Push RETURN icon for previous menu screen...

Page 19: ...n jog dial will let you hear the current volume Push RETURN icon for previous menu screen Voice says Applied Push RETURN icon again to complete set up Voice says Set up was completed If UP DOWN Icon is pushed digital number moves by one step Turn the Jog Dial clockwise or counter clockwise to select LANGUAGE Press the PUSH On Off button of the jog dial to make your selection When using the Jog Dia...

Page 20: ...og Dial clockwise or counter clockwise to select TIME Press the PUSH On Off button of the jog dial to make your selection When using the Jog Dial J O G D I A L J O G D I A L J O G D I A L Turn the Jog Dial clockwise or counter clockwise to select TOUCH Press the PUSH On Off button of the jog dial to make your selection When using the Jog Dial J O G D I A L J O G D I A L J O G D I A L Push RETURN i...

Page 21: ...creen MENU options will fall below the upper part of screen 2 Press the Cleaning icon Select the Voice icon 2 3 1 Press the top left corner of screen MENU options will fall below upper part of screen Cleaning can take place automatically and or manually The voice will be turned on off by selecting the voice icon in this sequence The automatic cleaning cycle will run after more than 12 hours of non...

Page 22: ...ntered into ECO Mode as you set When entering ECO Mode the screen will display the date and clock only If the screen is touched the unit will change to Standby Mode If you do not use the unit for more than 30 minutes in ECO mode it will be entered into the Power Save mode automatically When entering Power Save Mode the screen will become blank If the screen is touched the unit will change to Stand...

Page 23: ...INK Approx 5 5 pH For washing hands and face Medium Acidic Water DO NOT DRINK Approx 4 5 pH For washing vegetables and fruits Strong Acidic Water DO NOT DRINK Approx 3 5 pH For washing dishes 45 Usage Recommendations Under Counter Extreme 44 Usage Recommendations 15 00 15 00 15 00 15 00 15 00 15 00 15 00 05 00 DO NOT DRINK Strong acid alkaline water that must be used when cleaning disinfecting was...

Page 24: ...els control 2 Filters System LCD filter replacement and announcement 13 Platinum and Titanium For the best functionality there may be some changes without prior notice Should water with a temperature higher than 95 35 get into the unit the water supply will automatically be shut off and the unit will stop operating 1 2 Bring the source water temperature into the proper range 3 When your source wat...

Page 25: ...ng time exceeds 10 minutes When you re not using the unit for 10 minutes it changes to ECO mode automatically The unit returns to normal mode after touching the screen Q Abnormal taste 1 Check the period of use Run the unit for one minute draining stagnant water 2 Check the filter for replacement time Replace the filter Q Water outflow change 1 Check if the valve on the water supply is closed Open...

Page 26: ...lease call the service center Note The answers to many service questions can be found online at tyentusa com support In case of a failure resulting from the customer s negligence or intentional damage of the product the customer shall be responsible for repair or replacement costs 1 2 3 This warranty is non transferable and valid only for the original owner 4 WATER FOR WELLNESS Product Name Custom...

Reviews: