– Connect the device to an outlet on a circuit different from the one that supplies power to the receiver.

– Consult the dealer or an experienced radio/TV technician.

FCC Compliance Statement

This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are

designed to provide reasonable protection against harmful interference in residential installations. This equipment generates uses and can radiate radio

frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio and television reception.
However, there is no guarantee that interference will not occur in a particular installation. If this device does cause such interference, which can be

verified by turning the device off and on, the user is encouraged to eliminate the interference by one or more of the following measures:

l

Re-orient or re-locate the receiving antenna.

l

Increase the distance between the device and the receiver.

l

Connect the device to an outlet on a circuit different from the one that supplies power to the receiver.

l

Consult the dealer or an experienced radio/TV technician.

Warning!

Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to

operate the equipment.

This device complies with FCC Rules Part 15 and with Industry Canada licence-exempt RSS standard(s). Operation is subject to two conditions: (1)

This device may not cause harmful interference, and (2) this device must accept any interference that may be received or that may cause undesired

operation.
Le present appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisee aux

deux conditions suivantes :(1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioelectrique

subi, meme si le brouillage est susceptible d'en compromettre le fonctionnement.

W.E.E.E. Product Recycling Declaration

For information regarding the recycling of this product you must contact the company from which you orignially purchased it. If you are discarding this product and not returning it for repair then
you must ensure that it is returned as identified by your supplier. This product is not to be thrown away with everyday waste.

Directive 2002/96/EC Waste Electrical and Electronic Equipment.

4. APPENDIX: SPECIFICATIONS

OPTICAL

Black Mirror Max. Coverage

Up to 12 m (40 ft) / 90°

Detector Technology

8 independent quad PIR detectors operating in true Quad configuration

Figure 6. Coverage Pattern

A.

Top view

B.

Side view of each detector

Pet Immunity

Up to 18 Kg (40 lb)

ELECTRICAL

Input Power

Two 3V CR123A Lithium batteries

Caution!

Risk of explosion if battery is replaced by an incorrect type. Dispose of used battery according

to the manufacturer's instructions.

Battery Life (for typical use)

3 years

Low Battery Threshold

4.0 V

Operation voltage

4 V to 6.6 V

Current consumption

25 uA to150 mA

WIRELESS

Frequency Band (MHz)

Europe and rest of world: 433-434, 868-869 USA: 912-919

Maximum Tx Power

10 dBm @ 433 MHz, 14 dBm @ 868 Mhz

Communication Protocol

PowerG

Tamper Alert

Reported when a tamper event occurs and in any subsequent message, until the tamper switch is

restored

MOUNTING

D-304046 TOWER-20 PG2 Installation Instructions

6

Summary of Contents for TOWER-20AM

Page 1: ...is visible in sunlight l Automatic termination of walk test after 15 minutes l Microprocessor controlled temperature compensation l Immunity to pets weighing up to 18 Kg 40lb not pet alley see Table 1...

Page 2: ...g point B For wall tamper C Drill D Fasten Note The 2 screw holes enable adjustment of the bracket on the wall if required after testing E Three long screw F Two short screws Figure 2 Installation HOR...

Page 3: ...ver Closure Installation Notes Do not obscure the detector field of view with large objects 2 2 Battery Insertion It is recommended to perform the first batteries insertion on a flat surface see Figur...

Page 4: ...l settings LOW default HIGH and One Region Note For EN compliance the detector should be set to One Region DISARM ACTIVITY Define whether or not to set the activity time during Disarm mode Optional se...

Page 5: ...3 COMPLIANCE WITH STANDARDS Europe EN 300220 EN 301489 EN 62368 1 EN 60950 22 EN 50130 4 EN 50130 5 EN 50131 2 2 EN 50131 5 3 EN 50131 6 Type C Hereby Visonic Ltd declares that the radio equipment ty...

Page 6: ...ence that may be received or that may cause undesired operation Le present appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autori...

Page 7: ...mage caused by unauthorized attachment alterations modifications or foreign objects being used with or in conjunction with the Products damage caused by peripherals unless such peripherals were suppli...

Page 8: ...e Purchser s compliance with the Consumer Protection Law and Regulations expand any of the Manufacturer s warranty obligations under this warranty and the Purchaser shall be responsible for any warran...

Reviews: