Important:
Reliable reception must be assured. Therefore, "poor" signal strength is not acceptable. If you receive a "poor" signal from the detector, re-
locate it and re-test until a "Good" or "Strong" signal strength is received.
Note:
For detailed Diagnostics Test instructions refer to the control panel Installer's Guide
The LED blinking, described above, is operative only in Local diagnostic mode. Upon each full detection (LED lights steadily for 2 seconds), the control
panel receives the alarm. If required, perform the detector's horizontal / vertical adjustments (see section 2.1 and Figure 3).
Important:
Instruct the user to perform a walk test at least once a week, to verify proper operation of the detector.
D. Place a piece of cardboard on the detector’s front side to deliberately mask the optical window. Verify that after 2 minutes, the yellow LED lights
continuously (see Table 3 below) and the alarm control panel receives the masking alarm.
E. Remove the masking from the detector’s front side. Verify that the LED turns off
Table 3 - LED operation
LED Indications
Event
Red LED blinks
Stabilization (warm-up 60 sec)
Red LED ON 0.2 sec.
Tamper open / close
Red LED blinks twice
One quad PIR detection in diagnostic mode
Red LED on 2 sec.
Intruder alarm
Yellow LED on
AM detection – diagnostic mode
Yellow LED blinks slowly (0.2 sec. ON, 30 sec. OFF)
AM detection – Normal mode
Note:
After detection, the detector disables itself to save battery power. It reverts to the ready state if there is no subsequent detection throughout the
following 2-minute period.
Figure 5. TOWER 20 AM PG2
Callout
Description
A
LED
B
Enroll button
C
Tamper switch
3. COMPLIANCE WITH STANDARDS
Europe:
EN 300220, EN 301489, EN 62368-1, EN 60950-22, EN 50130-4, EN 50130-5, EN 50131-2-2, EN 50131-5-3, EN 50131-6
Type C.
Hereby, Visonic Ltd. declares that the radio equipment type TOWER-20 PG2 is in compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the following internet address:
http://www.visonic.com/download-center
.
Certified by
Norwegian
accredited certification body Applica Test & Certification AS in accordance with EN 50131-2-2, EN 50131-5-3,
EN 50131-6, EN 50130-4, and EN 50130-5.
EN 50131-1 Security Grade
: According to EN 50131-1 this equipment can be applied in installed systems up to and including Security
Grade 2.
EN 50131-1 Environmental Class:
Class IV, IP-55
UK:
This product is suitable for use in systems installed to conform to PD6662:2010 at Grade 2 and environmental class 4. DD243 and
BS8243
USA:
FCC-CFR 47 Part 15,
Canada:
IC-RSS 210
This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in residential installations. This equipment generates uses and can radiate
radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio and television
reception.
However, there is no guarantee that interference will not occur in a particular installation. If this device does cause such interference, which can be
verified by turning the device off and on, the user is encouraged to eliminate the interference by one or more of the following measures:
– Re-orient or re-locate the receiving antenna.
– Increase the distance between the device and the receiver.
D-304046 TOWER-20 PG2 Installation Instructions