background image

D-306041 WK141 Installation Instructions 

Step 5

 

Step 6 

Step 7

 

Step 8

 

Configure Location parameter 

Enter PARTITIONS. 

See Note 3 

Assign partitions to the keypad by 

pressing the 

 and 

 buttons on the panel 

Continue to section 2.3 

 

 

 

 

 

 

 

 

 

means scroll 

 and select

 

 

 

 

 

Notes: 
1

. If the keypad is already enrolled, you can configure the keypad parameters and assign partitions via the 

“Modify Devices” 

option 

– see Step 2. 

2.

 The first three digits of the Device ID No. "371-XXXX" refer to WK141.  

3.

 PARTITIONS will appear only if PARTITIONING was previously enabled in the panel (for further details, see "Partitioning" in the PowerMaster Installer Guide). 

2.3. Configuring the Keypad Parameters 

Enter the 

 

menu and follow the configuration instructions for the WK141

 

keypad as described in the following table. 

Option 

Configuration Instructions 

 

 

Here you determine which of the two tampers (i.e. battery compartment cover or all of the tampers) will be active.  

Optional settings: 

 Disabled

 (default); 

all tampers

Battery cover

Note:

 For UL Listed product

, set to “all tampers”. 

 

 

 

 

 

 

 

Here you determine whether or not the control panel will monitor supervision messages sent by the keypad or not (see Note).

 

Optional settings: 

ON 

(default) or

 OFF.

 

Notes: 

1.  Every 5 minutes the keypad performs a communication test session with the control panel (i.e. "Supervision signal) to check the 

integrity and quality of the Radio link. If the keypad does not report a supervision signal at least once within a predefined time 
window, a “MISSING” trouble alert is initiated. Therefore, if you intend to take the keypad out of the protected premises you must 
switch the Supervision OFF to avoid the trouble alert.

  

2. For UL Listed product

, set to “ON”. 

 

 

 

 

 

Here you determine whether the keypad will sound the exit and entry beeps, or not, or whether the keypad will sound the beeps only 
when the system is armed AWAY and not when it is armed HOME.

 

 

Optional settings: 

ON

OFF 

(default) and 

OFF @ Home

Note:

 For UL Listed product, the sounder cannot be used as the only annunciator for the system.

 

 

 

 

 

 

Here you select the function of the (AUX) button 

. Four options are offered: 

Status: 

Control panel displays and announces (applies only to control panels that support voice) the system status. 

Stop Beeps:

 Pressing the AUX button will cause the control panel and other devices in the system (such as keypads, sirens etc.) to 

stop beeping (for example during exit or entry delays).   

Skip exit delay:

 Pressing the AUX button will immediately stop the exit delay. 

PGM: 

Pressing  the  AUX  button  will  activate  the  PGM  output.

 

The  functions  of  the  PGM  output  is  configured  at  the  corresponding 

sections of the control panel’s Installer Guide (see “OUTPUTS” menu) and User Guide (see “SCHEDULER ” menu).

 

Not used:

 No function assigned to AUX button.

 

Optional settings:

 

Status

 

(default)

Stop Beeps

Skip exit delay

PGM

; and 

Not Used

Note: 

PGM not to be enabled in UL Listed Product.

 

 

2.4 Enrollment of Proximity Tags 

The built-in proximity tag reader of the WK141 can be also used to enroll proximity tags into the PowerMaster panel via the keypad as described in the corresponding 
section of the control panel's User or Installer Guide, or as explained in the general description provided below. 

Each proximity tag corresponds to its User Code. Therefore, be sure that a corresponding User Code is programmed for each enrolled proximity tag (code "0000" is 
not allowed). For example, "T02:Tag <Prox>" must be assigned to User Code 2 and "T14:Tag <Prox>" must be assigned to User Code 14. Partition authorization of 
each proximity tag is identical to that of the corresponding User Code. For example, if User Code 3 is set to Partitions 1 and 3, "T03:Tag <Prox>" will also be set to 

Partitions 1 and 3.  

 

 

 

 

 

 

 

Means scroll

 

 

and select

 

 

Step 1

 

Step 2

 

Step 3

 

Step 4

  

 

Enter the Installer menu of the control 
panel and select the 

02:ZONES/DEVICES

 

Select the "

ADD NEW DEVICES

" option   When "

ENROLL NOW

"

 

is displayed, 

press the AWAY button (

) on 

the WK141 keypad - the AWAY button 
begins to blink 

Present the proximity tag to the WK141 
keypad within the timeout period. If the 
enrollment is successful the display 
reads 

"

DEVICE ENROLLED

"

 and then 

shows the device details 

 

 

 

 

 

 

 

 

 

 

 

 

K06.LOCATION 

K06.PARTITIONS 

K06:P1

  P2    P3

 

 

K06.DEV SETTINGS 

DEVICE SETTINGS

 

TAMPERS 

SUPERVISION 

EXIT-ENTRY Beeps 

BUTTON (

02.ZONES/DEVICES 

 

MODIFY DEVICES 

 

ADD NEW DEVICES 

 

ENROLL NOW 

 

T01:Tag (Prox) 

 

DEVICE ENROLLED 

 