User Functions
User Functions
First disarm the system then enter Options, User Functions, then Master Code. This command is used to
gain access to the following list of master functions of the system:
Time and Date
Enter desired time and date.
Auto-Arm Time
The system can be programmed to arm at a programmed time each day, per partition. Upon entry of this sec-
tion, enter the desired Auto-Arm time for each day of the week.
At the selected Auto-Arm time, the keypad buzzers will sound for a programmed amount of time (pro-
grammable by the installer only) to warn that an auto-arm is in progress. The bell can also be programmed
to squawk once every 10 seconds during this warning period. When the warning period is complete, the sys-
tem will arm with no exit delay and in Away mode.
Auto-Arming can be canceled or postponed by entering a valid access code only during the programmed
warning period. Auto-Arming will be attempted at the same time the next day. When the Auto-Arming pro-
cess is canceled or postponed, the Auto-arm Cancelation Reporting Code will be transmitted (if pro-
grammed).
If arming is inhibited by one of the following, the Auto-Arm Cancelation transmission will be com-
municated:
l
AC / DC Inhibit Arm
l
Latching System Tampers
l
Zone Expander Supervisory Fault
Note:
For UL/ULC listed installations, the auto-arm feature shall be canceled when there are zones in an off-
normal condition.
Enable DLS/Allow System Service
If enabled, the installer will be able to access Installer Programming via remote (DLS). In case of DLS access
this provides a window where rings will be detected by the panel. The DLS window will remain open for 6
hrs, during which time the installer will be able to enter DLS an unlimited number of times. After the 6-hr
window has expired, Installer’s Programming will be unavailable again until the window is re-opened.
Event Buffer
l
Displays the date, time and the full description of the event
l
The Log is organized from the most recent event (Top) to past events (Down)
l
The Left arrow scrolls forward in time
l
The Right arrow scrolls back in time
l
The Back returns you to the Home screen
l
This screen will time out to the Home screen after 30 seconds of inactivity
System Test
The system’s Bell Output (2s), Keypad Lights and Communicator are tested. This test will also measure the
panel’s standby battery.