LIMITED WARRANTY

Products manufactured by Tyco Fire Products are war-
ranted solely to the original Buyer for ten (10) years
against defects in material and workmanship when paid
for and properly installed and maintained under normal
use and service. This warranty will expire ten (10) years
from date of shipment by Tyco Fire Products. No warranty
is given for products or components manufactured by
companies not affiliated by ownership with Tyco Fire Prod-
ucts or for products and components which have been
subject to misuse, improper installation, corrosion, or
which have not been installed, maintained, modified or re-
paired in accordance with applicable Standards of the Na-
tional Fire Protection Association, and/or the standards of
any other Authorities Having Jurisdiction. Materials found
by Tyco Fire Products to be defective shall be either re-
paired or replaced, at Tyco Fire Products’ sole option.
Tyco Fire Products neither assumes, nor authorizes any
person to assume for it, any other obligation in connec-
tion with the sale of products or parts of products. Tyco
Fire Products shall not be responsible for sprinkler sys-
tem design errors or inaccurate or incomplete information
supplied by Buyer or Buyer’s representatives.

IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LI-
ABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UN-
DER ANY OTHER LEGAL THEORY, FOR INCIDENTAL,
INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES,
INCLUDING BUT NOT LIMITED TO LABOR CHARGES,
REGARDLESS OF WHETHER TYCO FIRE PRODUCTS
WAS INFORMED ABOUT THE POSSIBILITY OF SUCH
DAMAGES, AND IN NO EVENT SHALL TYCO FIRE
PRODUCTS’ LIABILITY EXCEED AN AMOUNT EQUAL
TO THE SALES PRICE.

THE FOREGOING WARRANTY IS MADE IN LIEU OF
ANY AND ALL OTHER WARRANTIES EXPRESS OR IM-
PLIED, INCLUDING WARRANTIES OF MERCHANT-
ABILITY AND FITNESS FOR A PARTICULAR PUR-
POSE.

ORDERING PROCEDURE

Please Specify:

1 Star Galaxy SG-R, 4.3 K-Factor, Residential

Pendent Sprinkler (#2287)

2. Recessed Escutcheon(#2084)
3. W-Type 9 Sprinkler Wrench (#1849)
4. W-Type 10 Recessed Sprinkler Wrench (#1948)

Refer to Price List for a complete listing of Part Numbers
with respect to temperature ratings, finishes, etc.

STAR SPRINKLER

Page 8

1-3.2.10

7071 S. 13th Street • Suite 103

Oak Creek, WI 53154

www.starsprinkler.com

PRINTED IN U.S.A. 7-02

OBSOLETE

Summary of Contents for Star Galaxy SG-R

Page 1: ...he above cited stipulations and the var ied nature of residential type architecture there will be some compartment designs which cannot be fully sprinklered in accordance with the recommendations of N...

Page 2: ...rge from each of the total number of design sprinklers as speci fied in NFPA 13D or 13R TIA 99 1 Tentative Interim Amendment with an effective date of May 22 2000 states that the minimum required disc...

Page 3: ...r tight ening the Sprinkler Readjust the position of the sprin kler fitting to suit 1 The sprinkler must only be installed in the pendent position and with the deflector parallel to the mounting surfa...

Page 4: ...STAR SPRINKLER Page 4 1 3 2 10 FIGURE 5 PLAN VIEW ILLUSTRATIONS OF SPRINKLER TO WALL AND SPRINKLER TO SPRINKLER POSITIONING O B S O L E T E...

Page 5: ...IRED HORIZONTAL DISTANCE BETWEEN TWO SPRINKLERS LOCATED ON THE SAME ELEVATION ON OPPOSING SLOPED CEILINGS FIGURE 7 MAXIMUM PERMITTED VERTICAL DISTANCE BETWEEN THE SPRINKLER DEFLECTOR AND THE BOTTOM OF...

Page 6: ...EQUIRED HORIZONTAL DISTANCE BETWEEN A SPRINKLER LOCATED ON A LEVEL CEILING AND AN INTERSECTING SLOPED CEILING FIGURE 9 MINIMUM REQUIRED SLANT DISTANCE BETWEEN A LEVEL CEILING AND A SPRINKLER LOCATED O...

Page 7: ...be painted plated coated or otherwise al tered after leaving the factory Modified sprinklers must be replaced Sprinklers that have been exposed to corro sive products of combustion but have not operat...

Page 8: ...le of products or parts of products Tyco Fire Products shall not be responsible for sprinkler sys tem design errors or inaccurate or incomplete information supplied by Buyer or Buyer s representatives...

Reviews: