SOLARLOK Interconnection System
2-1773458-2
Issued 8-2010
Installation Manual
tycoelectronics.com/solar
All specifications subject to change. Consult Tyco Electronics for latest specifications.
1
(2)
(3)
(2
)
(3)
(1)
(2)
(3)
(4)
1. Safety Note
■
The SOLARLOK connector is to be used only to
interconnect firmly fixed cables.
■
Do not disconnect under electrical load!
■
Electrical current path should only be disconnected
using approved devices.
■
Only cables released from Tyco Electronics are permitted
to be used with SOLARLOK component cable assemblies.
■
SOLARLOK component cable shall be labelled with label
PN 1718077-1 “Do not disconnect under load”.
■
To protect against shock, ensure that conductors and
their associated connectors are separated from opposite
polarity components.
■
Unconnected connectors
must
always be protected from
pollution (e.g. dust, humidity, foreign particles, etc.), pri-
or to installation. Do not leave unconnected (unprotect-
ed) connectors exposed to the environment. The usage
of TE connector dust caps is strongly recommended.
■
Connectors that are unmated in the field should also be
protected from pollutants.
■
Do
NOT
use any
oil or lubricants
during mounting.
2. Tools
(1) Stripping Tool
1.5 mm
2
– 6.0 mm
2
, 10 AWG
PN 4-1579002-2
(2) Crimping Tool
4.0 mm
2
and 6.0 mm
2
, 10-12 AWG PN 1-1579004-2
(3) Extraction Tool
all terminals
PN 1102855-3
(4) Field Service Kit
all in one
PN 1534858-1
!