SAFETY (continued)

       

    Safety Precautions and

General Warnings
•  The heat gun must be placed on its
stand when not in use.

•  A fire may arise if the 240-Vac AA-
400 Mark IV super heater is not used
with

care.

•  Be careful when using the AA-400
Mark IV in places where there are
combustible materials.

•  Do not apply heat to the same area
for a prolonged period.

•  Do not use this tool in the presence of
explosive atmosphere.

•  Heat may be conducted to
combustible materials that are out of
sight.

•  Place the AA-400 Mark IV on its
stand after use and allow it to cool
before storing it.

•  Do not leave the AA-400 Mark IV
unattended when it is not in use.

            Electrical
The AA-400 Mark IV-control unit is
connected directly to the AC mains

electrical supply through a double-fused
chassis plug and detachable power cord.

Before performing any electrical
maintenance or repair, always turn off
the equipment and unplug it from the
mains supply.

Do not open the control unit case or
heat gun case while the equipment is
connected to the mains supply.

 

The AA-400 Mark IV equipment must

be connected to an earthed power
supply.
It should not be hard-wired to a mains
supply.

Use only specified fuse types and
ratings.

Eye Protection
Safety glasses should be worn when
operating this tool. Avoid aiming the
heat gun nozzle’s hot air stream toward
your face.

Fire Prevention
Parts of the AA-400 Mark IV become
heated during normal usage. Avoid
aiming the heat gun nozzle’s hot air
stream at the unit’s hose, power cord, or
control unit.

Before disconnecting the operating
AA-400 Mark IV air supply, first allow
the heating element to cool. Failure to
observe this precaution will reduce the

element’s product life and could lead to
melting of the plastic in the heat gun
handle.

Always use the AA-400 Mark IV in a
well-ventilated area, away from any
flammable
materials, liquids, or fumes.

Be sure the AA-400 Mark IV is not
placed on flammable materials between
uses. Always place the heat gun in its
stand when not in use.

Emergency Shutoff
The AA-400 Mark IV is not equipped
with
an emergency shutoff system.

To turn the equipment off, first reduce
the air pressure to 0.21 MPa (30 psi) for
one minute. The green HEAT ON
indicator light will go off when the
pressure drops below approximately
0.31 MPa (45 psi), indicating power to
the heating element has been shut off.
After one minute at 0.21 MPa
(30 psi), reduce the air pressure to zero.

The equipment can be powered off by
unplugging the power lead from the
mains supply.

            Hot Surfaces
Parts of the AA-400 Mark IV and the
product being worked on will become
heated during use. Always place the
heat gun in the stand when not in use.

Always provide adequate ventilation

and avoid overheating any products or
solder devices. Charring or burning of
tubing or wire insulation will produce

fumes that may cause eye, skin, nose, or
throat irritation.

Raychem Interconnect a division of Tyco Electronics International Ltd.    Printed in USA    No.: TUS-44-3300 Revision: None

Revision Date:  February 16, 2000  Page: 4 of  8

Summary of Contents for Raychem Interconnect AA-400 Mark IV

Page 1: ......

Page 2: ...3 4 Operation 4 5 Accessories and Replacement Parts 5 6 Technical Specifications 5 Section Title Page Raychem Interconnect a division of Tyco Electronics International Ltd Printed in USA No TUS 44 33...

Page 3: ...nual Incorrect use of the AA 400 Mark IV can cause serious injury This equipment must be operated and maintained only by fully trained and qualified personnel Failure to follow the manufacturer s inst...

Page 4: ...Avoid aiming the heat gun nozzle s hot air stream at the unit s hose power cord or control unit Before disconnecting the operating AA 400 Mark IV air supply first allow the heating element to cool Fa...

Page 5: ...eating The green HEAT ON indicator light is illuminated whenever power is applied to the heating element This light goes off when the pressure switch cuts off power to the element Step 4 Within 30 sec...

Page 6: ...away from the device The hot air stream should be directed at the solder band Closer placement of the nozzle tip can result in browning of the tubing or spurting of the melted solder Step 6 The needle...

Page 7: ...ION 6 TECHNICAL SPECIFICATIONS Power supply 240 Vac 2A 50 60 Hz Power consumption 363 watts Fuses 2 x 2A 5 x 20 mm Power supply cable length 2 meters Lamp 240 Vac green Air connection requirements 1 4...

Page 8: ...tice In addition Raychem re serves the right to make changes without notification to Buyer to processing or materials that do not affect compliance with any applicable specification SolderSleeve Solde...