Page 15 / 18 ECOC: EGC0 ; LOC: AI
P/N 2-744014-3
411-18341 Rev.B
Figure 2
6 Set-up (including equipping)
Inserting a contact
1. Before inserting a contact the tool needs to be opened fully. Now the locking is opened by turning it,
the contact positioner is swievelled out to the front and the contact is pushed to the stop into the
positioner. Pay attention that the u-profile of the crimping- and insulation flanks shows upwards in
direction of the crimper (see figure 3 and 4).
Figure 3
Figure 4
2. Now the contact positioner is swivelled back whereby the contact is exactly positioned over the anvil.
The locking is closed again by turning it.
Adjusting the insertion depth of the contact
In order to adjust the insertion depth the contact positioner was equipped with a setscrew. Turning it
clockwise reduces the insertion depth, turning it anti-clockwise increases the insertion depth (see figure
5).
Contact
Positioner
Locking