background image

 

http://www.tyan.com 

185 

3.5.1.1      Key Management   

 

 

Provision Factory Default keys 

Allow to provision factory default Secure Boot keys when System is in Setup Mode. 

Disabled / 

Enabled 

 
Restore Factory Keys 

Force System to User Mode. Install Factory Default Secure Boot key databases. 

 
Reset To Setup Mode 

Delete all Secure Boot key database from NVRAM 

 
Export Secure Boot variables 

Copy  NVRAM  content  of  Secure  Boot  variables  to  files  in  a  root  folder  on  a  file 
system device 

 
Enroll Efi Image 

Allow the image to run in Secure Boot mode. Enroll SHA256 has of the binary into 
Authorized signature Database (db). 

 
 
 
 

Summary of Contents for B5642F65TV8E2H-2T-N

Page 1: ...1 http www tyan com FT65T B5642 Tower Server Engineer s Manual...

Page 2: ...ing liability or warranties relating to fitness for a particular purpose or merchantability MITAC retains the right to make changes to produce descriptions and or specifications at any time without no...

Page 3: ...s and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that int...

Page 4: ...Way Crawley RH10 1JH U K Warning This equipment is compliant with Class B of CISPR 32 In a residential environment this equipment may cause radio interference CAUTION Lithium battery included with thi...

Page 5: ...chapter provides an introduction to the TYAN FT65T B5642 barebones and standard parts list describes the external components gives an overview of the product from different angles Chapter 2 Setting U...

Page 6: ...the purpose of this pin If your outlet does not support this kind of plug contact your electrician to replace your obsolete outlet Do not place anything on the power cord Place the power cord where it...

Page 7: ...d Consult equipment documentation for specific details Caution Slide mounted equipment is not to be used as a shelf or a work space Warning This symbol indicates the presence of hazardous energy circu...

Page 8: ...t Chassis Do not block or cover the openings to the system Never push objects of any kind through openings in the equipment Dangerous voltages might be present Conductive foreign objects can produce a...

Page 9: ...epth must allow for proper serviceability and cable management Ensure that there is adequate airflow in the rack Improper installation or restricted airflow can damage the equipment The rack cannot ha...

Page 10: ...pment Batteries The system battery contains lithium manganese dioxide If the battery pack is not handled properly there is risk of fire and burns Do not disassemble crush puncture short external conta...

Page 11: ...rings or loose jewelry when working before removing covers and touching internal components Do not use conductive tools that could bridge live parts Use gloves when you remove or replace system compon...

Page 12: ...1 Installing Motherboard Components 42 2 1 1 Removing the Chassis Cover 42 2 1 2 Installing the CPU and Heatsink 44 2 1 3 Installing the Expansion Cards 47 2 1 4 Installing the Memory 49 2 1 5 Instal...

Page 13: ...83 Chapter 4 BIOS Setup 85 4 1 About the BIOS 85 4 2 Main Menu 87 3 3 Advanced Menu 89 3 4 Server Management 179 3 5 Security 183 3 6 Boot 188 3 7 Save Exit 190 Appendix I How to recover UEFI BIOS 192...

Page 14: ...l the FT65T B5642 Tower Server system is capable of offering scalable 64 bit computing high bandwidth memory design and lightning fast PCI E bus implementation The FT65T B5642 not only empowers your c...

Page 15: ...defined by the following models B5642F65TV8E2H G Intel based platform B5642F65TV8E2H 2T N Intel based platform SKU Differences Model Name FT65T B5642 SKU Name B5642F65TV8E2H G B5642F65TV8E2H 2T N MB S...

Page 16: ...ckplane Support SAS 12Gb s SATA 6Gb s NVMe Supported HDD Interface 2 SATA 6Gb s NVMe 8 SATA 6Gb s SAS 12Gb s Notification The SAS SATA HDD backplane is connected to onboard SATA connection by default...

Page 17: ...port 1 GbE dedicated for IPMI Controller Intel I210 PHY Realtek RTL8211E Storage SATA Connector 2 7 pin SATA 6G ports 1 Mini SAS HD 4 ports Controller Intel C621A Speed 6Gb s RAID RAID 0 1 10 5 Intel...

Page 18: ...or Fan PSU fail LED indicator Others Watchdog timer support Server Management Onboard Chipset Onboard Aspeed AST2500 AST2500 iKVM Feature 24 bit high quality video compression Supports storage over IP...

Page 19: ...g Environment Operating Temp 0 C 40 C 32 F 104 F Non operating Temp 40 C 70 C 40 F 158 F In Non operating Humidity 90 90 non condensing at 35 C Package Contains Barebone 1 FT65T B5642 Barebone Manual...

Page 20: ...wap HDD SSDs HDD Backplane Support SAS 12Gb s SATA 6Gb s NVMe Supported HDD Interface 2 SATA 6Gb s NVMe 8 SATA 6Gb s SAS 12Gb s Notification The SAS SATA HDD backplane is connected to onboard SATA con...

Page 21: ...PCIe 1 PCIe Gen 4 x8 slot 4 w x4 link 1 PCIe Gen 4 x8 slot 2 via MUX 1 PCIe Gen 4 x16 slot 3 w x8 link 2 PCIe Gen 4 x16 slots 5 6 LAN Q ty Port 2 10GbE ports 1 GbE ports 1 GbE dedicated for IPMI Cont...

Page 22: ...for IPMI Button ID Button SATA 14 SATA III ports from AHCI TPM Optional TPM Support Please refer to our TPM supported list System Monitoring Chipset Aspeed AST2500 Temperature Monitors temperature fo...

Page 23: ...P Wake on LAN ACPI 6 2 ACPI sleeping states S5 Operating System OS supported list Please refer to our AVL support lists Regulation FCC SDoC Class B CE DoC Class B RCM Class B VCCI Class B Operating En...

Page 24: ...ld arrive packaged as illustrated below 1 4 1 Box Contents FT65T B5642 Box Content 4U Chassis 1 2000W PSU 80 gold 1 M1309F65T BP12 8 HDD Backplane 1 M1298T65 BP12E 2 HDD Backplane 1 M1713G24 FPB Front...

Page 25: ...http www tyan com 25 1 5 About the Product The following views show you the product 1 5 1 System Front View...

Page 26: ...th LED 9 ID LED 10 HDD LED 11 IPMI LED Fault LED M1713G24 FPB Front Panel Board Switch and LED Indication M1713G24 FPB R01 LED Definitions LED STATE COLOR DESCRIPTION Power LED ON GREEN system is turn...

Page 27: ...stem Use a pin ID UID Press ID button when the system is AC Alternating Current on then ID LED will show the system is identified with emitting blue light Users from remote site could also activate ID...

Page 28: ...ew B5642F65TV8E2H 2T N 1 PSU 7 VGA Port 2 Audio Jack 8 RJ45 LAN Port 4 LAN4 3 COM Port 9 Dedicated IPMI RJ45 LAN Port 3 LAN3 4 USB 2 0 Ports x2 10 RJ45 LAN Port 2 LAN2 5 USB 3 2 Gen1 Ports x2 11 ID Bu...

Page 29: ...w tyan com 29 B5642F65TV8E2H G 1 PSU 6 VGA Port 2 Audio Jack 7 RJ45 LAN Port 2 LAN2 3 COM Port 8 Dedicated IPMI RJ45 LAN Port 1 LAN1 4 USB 2 0 Ports x2 9 ID Button 5 USB 3 2 Gen1 Ports x2 10 Expansion...

Page 30: ...d Yellow Active Blinking Green Solid Yellow 10Gbps Link Yellow Solid Yellow Active Blinking Yellow Solid Yellow NOTE Left and Right are viewed from the rear panel ID LED Definition LED State Color Des...

Page 31: ...in accordance with PSU redundancy and AC input range Please refer to the following table for details AC input 100 240V 15 12A 60 50Hz DC Output 3 3V 5V 12V 12V 5Vsb Max Output Current 25A 25A 166 6A...

Page 32: ...FAN3 2 Reserved space for slim CD dummy 9 Power supply 3 Reserved space for 2 5 HDD trays 10 CPU Socket 4 2 2 5 HDD SSD trays M1298T65 BP12E 2 HDD Backplane pre installed 11 Memory Slots 5 8 2 5 3 5...

Page 33: ...7 FAN2 2 Reserved space for slim CD dummy 8 FAN3 3 Reserved space for 2 5 HDD trays 9 Power supply 4 2 2 5 HDD trays M1298T65 BP12E 2 HDD Backplane pre installed 10 CPU Socket 5 8 3 5 HDD trays M1309F...

Page 34: ...http www tyan com 34 1 5 4 Chassis Dimensions...

Page 35: ...tyan com 35 1 5 5 Board Image S5642AGM3NRE 2T This picture is representative of the latest board revision available at the time of publishing The board you receive may not look exactly like the above...

Page 36: ...http www tyan com 36 1 5 6 Block Diagram S5642 Block Diagram...

Page 37: ...sion available at the time of publishing The board you receive may not look exactly like the above diagram The DIMM slot numbers shown above can be used as a reference when reviewing the DIMM populati...

Page 38: ...SYS_FAN_5 14 Fan Connector for BB FAN_HD1 33 4 pin FAN Connector SYS_FAN_4 15 COM Port Header HD_COM2 34 4 pin FAN Connector SYS_FAN_3 16 SMBus Header HDR_3 35 4 pin FAN Connector SYS_FAN_2 17 Vertic...

Page 39: ...0 x ID LED ID_LED1 iv CPU ERROR LED ERR_LED1 xi BMC Heart Beat LED BMC_LED4 v NGFF2 LED D9 xii System Reset LED SYS_RST_LED1 vi NGFF1 LED LED75 xiii BMC DEBUG LED BMC_LED1 vii Onboard PSMI ALERT LED P...

Page 40: ...vent you from accidentally damaging the internal components 2 0 3 Tools The following procedures require only a few tools including the following A cross head Phillips screwdriver A grounding strap or...

Page 41: ...d touching motherboard components IC chips connectors memory modules and leads The motherboard is pre installed in the system When removing the motherboard always place it on a grounded anti static su...

Page 42: ...cribes how to install components on to the motherboard including CPUs memory modules SSD HDD and PCI E cards 2 1 1 Removing the Chassis Cover Follow these instructions to remove the FT65T B5642 chassi...

Page 43: ...http www tyan com 43 NOTE When installing the top cover pay attention to the diagonal direction as Shown by the arrow can easily buckle the top cover...

Page 44: ...ink Then install the carrier on the bottom of the heatsink and make sure the latches are snapped under the edge of the heatsink 2 Align and install the processor on the carrier Make sure the gold arro...

Page 45: ...with the CPU socket by the guide pins Make also sure that the triangle edge of the carrier is aligned correctly with the triangle mark on the CPU socket Then place the heatsink assembly onto the top...

Page 46: ...screws in reverse order 4 3 2 1 NOTE Use a T 30 Torque Driver 8in lbs is recommended but torques in the 6 12 in Ibf range are supported with a durability at 12 in lbf of 20 cycles NOTE Always check w...

Page 47: ...2 1 3 Installing the Expansion Cards Follow the instructions to install the expansion cards 1 Locate the PCI E Gen 4 slots on the motherboard Unscrew to take out the dummy brackets 2 Screw the GPU bra...

Page 48: ...http www tyan com 48 3 Insert the GPU card into the PCIE Gen 4 slot and screw the GPU card to the chassis 4 Connect the GPU Power cable...

Page 49: ...herboard 2 Press the memory slot locking levers in the direction of the arrows as shown in the following illustration 3 Align the memory module with the slot When inserted properly the memory slot loc...

Page 50: ...1 indicates a populated DIMM slot 2 Use paired memory installation for max performance 3 Populate the same DIMM type in each channel specifically Use the same DIMM size Use the same of ranks per DIMM...

Page 51: ..._DIM_CH_F0 P0_MC3_DIM_CH_G0 P0_MC3_DIM_CH_H0 NOTE 1 indicates a populated DIMM slot 2 Use paired memory installation for max performance 3 Populate the same DIMM type in each channel specifically Use...

Page 52: ...SSD HDD Follow these instructions to install a hard drive Warning Always install the hard disk drive to the chassis after the chassis is secured on the rack 3 5 HDD Follow these instructions to insta...

Page 53: ...3 5 2 5 SSD HDD into the HDD tray 3 5 HDD 2 5 SSD HDD 4 Turn over the HDD unit and secure the SSD HDD using 4 HDD screws 5 Reinsert the HDD tray into the chassis and press the locking lever to secure...

Page 54: ...http www tyan com 54 2 5 NVMe HDD Follow these instructions to install the 2 5 NVMe HDDs into the chassis 1 Press the locking lever latch and pull the locking lever open 2 Slide the NVMe HDD tray out...

Page 55: ...DD 5 Reinsert the HDD tray into the chassis and press the locking lever to secure the tray Close the front bezel NOTE When installing a 2 5 HDD the tray must be push to the end and then press down the...

Page 56: ...42 into an industry standard 19 rack NOTE Before mounting the TYAN FT65T B5642 in a rack ensure that all internal components have been installed and that the unit has been fully tested However to make...

Page 57: ...http www tyan com 57 3 Screw the mounting ears to the FT65T B5642 as shown using six M4 L5 screws black Left Right 4 Press the latch to draw out the inner rails from each rail assembly...

Page 58: ...http www tyan com 58 5 Install the inner sliding rail to each side of the server using four M4 L5 screws...

Page 59: ...the Rack 1 Attach the outer rail to the rack Pull the latch open and align the square stud with the square hole on the rack rail Please note that the square stud must be fully attached inside the squa...

Page 60: ...http www tyan com 60 2 2 2 Rack Mounting the Server 1 Lift the unit and then insert the inner slide rails into the middle rails...

Page 61: ...http www tyan com 61 2 Push the whole system in 3 Secure the mounting screw to the rack...

Page 62: ...http www tyan com 62 2 2 3 Removing the Server from Rack 1 Use a screw driver to unscrew the chassis 2 Push the latch on both sides of the chassis simultaneously to pull the system out...

Page 63: ...3 Pull out the chassis half way to the lock position Push the white locking tabs forwards to slide the chassis all out from the rack Caution Remove the server from the rack carefully Must be done wit...

Page 64: ...pter explains how to replace the pre installed components including the S5642 Motherboard M1713G24 FPB Front Panel Board M1309F65T BP12 8 M1298T65 BP12E 2 HDD Backplane System Fan and Power Supply Uni...

Page 65: ...42 to remove the cover of the FT65T B5642 3 2 Replacing Motherboard Components Follow these instructions to replace motherboard components including the motherboard 3 2 1 Replacing the System Fan Foll...

Page 66: ...ttp www tyan com 66 Replacing Rear Fans Follow these instructions to replace the system fan 1 Release two thumb screws with the screwdriver 2 Turn over the rear fan module 3 Disconnect the fans cables...

Page 67: ...module 5 Take out the fans 6 Follow the steps described earlier in reverse to reinstall a new fan Tighten the thumb screws of rear fan module with a screwdriver after rear fans are replaced 7 Install...

Page 68: ...oard Follow these instructions to replace the M1309F65T BP12 8 HDD Backplane Board 1 Disconnect all cables attached to the HDD BP Board 2 Unscrew to take it out 3 Prepare a new HDD BP Board and reinst...

Page 69: ...nstructions to replace the M1298T65 BP12E 2 HDD Backplane Board 1 Disconnect all cables attached to the HDD BP Board 2 Unscrew to take it out 3 Prepare a new HDD BP Board and reinstall it into the cha...

Page 70: ...ne Board in details Front view Rear view M1309F65T BP12 8 HDD Backplane Board Specifications 2 Mini SAS HD Connectors CN10 CN11 1 FAN System Connector J4 8 SATA HDD Connector CN2 CN3 CN4 CN5 CN6 CN7 C...

Page 71: ...9 S3 SAS 0 7 _TX_DN0 E10 S4 GND E11 S5 SAS 0 7 _RX_DN0 E12 S6 SAS 0 7 _RX_DP0 E13 S7 GND GND S8 E4 NC S9 E5 NC S10 E6 GND S11 P1 NC NC S12 P2 NC NC S13 P3 NC GND S14 P4 NC S15 P5 GND S16 P6 GND S17 P7...

Page 72: ...B GND B6 D6 GND SAS 2 6 _TX_DP0 B7 D7 SAS 2 6 _RX_DP0 SAS 2 6 _TX_DN0 B8 D8 SAS 2 6 _RX_DN0 GND B9 D9 GND SAS 3 7 _TX_DP0 A7 C7 SAS 3 7 _RX_DP0 SAS 3 7_TX_DN0 A8 C8 SAS 3 7 _RX_DN0 GND A9 C9 GND J4 S...

Page 73: ...A_JTAG_TDI 9 10 GND J2 DEBUG SGPIO Pin Header DEFAULT PIN PIN DEFAULT DBG_BMC_SMB_SCL 1 2 DBG_SGPIO_DOUT1 DBG_BMC_SMB_SDA 3 4 DBG_SGPIO_DOUT0 GND 5 6 DBG_SGPIO_LOAD KEY pin 7 8 DBG_SGPIO_CLK 3V_AUX 9...

Page 74: ...BY SAS03 CONN CN11 J7 ATX Power connector Power supply to BP DEFAULT PIN PIN DEFAULT VDD_12_RUN 5 1 GND VDD_12_RUN 6 2 GND VDD_12_RUN 7 3 GND VDD_12_RUN 8 4 GND J6 ATX Power connector Power supply to...

Page 75: ...d in details Front View Rear View PCB Dimensions 76mm 33 5mm 3mm Thickness 3mm Layer 8 layers Integrated I O Slimsas Connector J1 SATA NVMe Connector NVME0 SATA NVMe Connector NVME1 SATA Connector SAT...

Page 76: ...Front Panel Control Board 1 Unscrew the front panel unit 2 Slide the LED control board unit out of the chassis 3 Disconnect the cables and remove three screws securing the mylar and LED control board...

Page 77: ...ures Integrated I O 10 2 USB3 2 Gen1 Header connect to MB 15 2 Header connect to MB 2 USB3 2 Gen1 connector LEDs 1 GREEN BLUE LED for LAN1 and ID 1 GREEN GREEN LED for LAN2 and HDD 1 GREEN AMBER LED f...

Page 78: ...P_USB3_TX_P1 FP_USB3_TX_N1 15 16 GND FP_USB3_RX_P1 17 18 FP_USB3_RX_N1 VCC_USB 19 20 key J3 15 2 Header Definition Pin Pin Definition PW_LED 1 2 VCC key 3 4 ID_LED PW_LED 5 6 ID_LED HDD_LED 7 8 SYS_FA...

Page 79: ...has one pre installed Power Supply Units Please unplug the power cord before you follow these instructions to replace the power supply units 1 Disconnect the power supply cable 2 Unscrew to release th...

Page 80: ...http www tyan com 80 4 Take out the power supply unit 5 To replace a new power supply And follow the procedures in reverse order to install a new power supply...

Page 81: ...http www tyan com 81 Power supply Unit GPU PWR Connection...

Page 82: ...http www tyan com 82...

Page 83: ...rd 1 Refer to the sections described earlier to remove all cables and components on the motherboard 2 Unscrew the motherboard 3 Carefully lift the motherboard from the chassis 4 Prepare a new motherbo...

Page 84: ...http www tyan com 84 NOTE...

Page 85: ...to change and therefore may not match exactly what is displayed on screen This section describes the BIOS setup program The setup program lets you modify basic configuration settings The settings are...

Page 86: ...eemingly small change to the Chipset setup options may cause the system to become unstable or unusable 4 1 4 Setup Variations Not all systems have the same BIOS setup layout or options While the basic...

Page 87: ...options listed below are for options that can directly be changed within the Main Setup screen BIOS Information It displays BIOS related information Product Name It displays Product information BIOS V...

Page 88: ...memory size Memory Frequency It displays Memory frequency System Language Choose the system default language System Date Set the Date Use Tab to switch between Date elements Default Ranges Year 1998...

Page 89: ...ons for your system Option ROM Dispatch Policy Option ROM Dispatch Policy S5 RTC Wake Settings S5 RTC Wake Settings Trusted Computing Trusted Computing settings ACPI Settings System ACPI Parameters AS...

Page 90: ...vice Options Settings Onboard Device Configuration Onboard Device and Function Configuration Redfish Host Interface Settings Redfish Host Interface Parameters Network Stack Configuration Network Stack...

Page 91: ...rameters VLAN Configuration MAC XXXXXXXXXXXX VLAN Configuration MAC XXXXXXXXXXXX MAC XXXXXXXXXXXX IPV4 Network Configuration Configure network parameters MAC XXXXXXXXXXXX MAC XXXXXXXXXXXX IPV6 Network...

Page 92: ...Configuration On Board LAN1 X550 Onboard Device has UEFI X Legacy Embedded ROM s VIDx8086 DID x1563 s0 BxC5 Dx0 Fx0 Disabled Enabled On Board LAN2 X550 Onboard Device has UEFI X Legacy Embedded ROM s...

Page 93: ...2 Dx0 Fx0 Disabled Enabled Slot 1 2 3 4 5 Empty Enable or Disable Option ROM execution for selected Slot Disabled Enabled 3 3 2 S5 RTC Wake Settings RTC Wake system from S4 S5 Enable or disable System...

Page 94: ...ed Computing Security Device Support Enable or Disable BIOS support for security device O S will not show Security device O S will not show Security Device TCG EFI protocol and INT1A interface will no...

Page 95: ...ACPI Auto Configuration Enables or Disables BIOS ACPI Auto Configuration Disabled Enabled Enable Hibernation Enables or Disables System ability to Hibernate OS S4 Sleep state This option may not be ef...

Page 96: ...http www tyan com 96 3 3 5 AST2500 Super IO Configuration Serial Port 1 Configuration Set Parameters of Serial Port 1 COMA Serial Port 2 Configuration Set Parameters of Serial Port 2 COMB...

Page 97: ...M Enabled Disabled NOTE The following items will appear when Serial Port set to Enabled Change Settings Select an optimal setting for Super IO Device Auto IO 3F8h IRQ 4 IO 3F8h IRQ 3 4 5 6 7 9 10 11 1...

Page 98: ...rt Enable or disable Serial Port COM Enabled Disabled Change Settings Select an optimal setting for Super IO Device Auto IO 2F8h IRQ 3 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12...

Page 99: ...http www tyan com 99 3 3 6 Power Management Configuration CPU Power and Performance Policy CPU Power and Performance Policy Performance Balanced Power Power...

Page 100: ...al Port for Out Of Band Management Windows Emergency Services EMS Console Redirection Console redirection enable or disable Disabled Enabled Console Redirection Settings The settings specify how the h...

Page 101: ...erial port transmission speed The speed must be matched on the other side Long or noisy lines may require lower speeds 38400 9600 19200 115200 57600 Data Bits 8 7 Parity A parity bit can be sent with...

Page 102: ...to stop the data flow Once the buffers are empty a start signal can be sent to re start the flow Hardware flow control uses two wires to send start stop signal None Hardware RTS CTS VT UTF8 Combo Key...

Page 103: ...erial port transmission speed The speed must be matched on the other side Long or noisy lines may require lower speeds 38400 9600 19200 115200 57600 Data Bits 8 7 Parity A parity bit can be sent with...

Page 104: ...to stop the data flow Once the buffers are empty a start signal can be sent to re start the flow Hardware flow control uses two wires to send start stop signal None Hardware RTS CTS VT UTF8 Combo Key...

Page 105: ...Resolution On Legacy OS the Number of Rows and Columns supported redirection 80x24 80x25 Redirect After POST When Bootloader is selected then Legacy Console Redirection is disabled before booting to l...

Page 106: ...through a serial port COM1 COM2 Terminal Type EMS VT UTF8 is the preferred terminal type for out of band management The next best choice is VT100 and then VT100 See above in Console Redirection Setti...

Page 107: ...ta if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to restart the flow Hardware flow control uses two wires to s...

Page 108: ...sables 64bit capable Devices to be decoded in Above 4G Address Space Only if System supports 64 bit PCI Decoding Enabled Disabled SR IOV Support If system has SR IOV capable PCIe devices this option E...

Page 109: ...RefCode Configuration Displays and provides option to change the Common RefCode Settings Memory Configuration Displays and provides option to change the Memory Settings IIO Configuration Displays and...

Page 110: ...TXT Enable Intel TXT Disabled Enabled Intel Virtualization Technology Intel Virtualization Technology allows a platform to run multiple operating systems and applications in independent partitions No...

Page 111: ...512M 1G 2G Auto MMIO High Base Select MMIO High Base 56T 40T 32T 24T 16T 4T 3T 2T 1T MMIO High Granularity Size Selects the allocation size used to assign mmioh resources Total mmioh space can be up...

Page 112: ...Enabled UMA Based Clustering UMA Based Clustering options include Disable ALL2ALL Hemisphere 2 cluster not supported on ICX These option are only valid when SNC is disabled If SNC is enabled UMA Base...

Page 113: ...y Limit field limited by processor support Auto Sets it to the MRC default setting current default is Enable Enforce POR Disabled Halt on mem Training Error Halt on mem Training Error Disable Enable D...

Page 114: ...Sets it to the MRC default setting current default is Disable Disabled Enabled RMT On Cold Fast Boot Enable Enables Rank Margin Tool on Cold Fast Boot Disable Disables this feature Auto Sets it to th...

Page 115: ...ed If rank sparing is enabled partial mirroring will not take effect Enabling any type of Mirror Mode will disable XPT Prefetch Disabled Full Mirror Mode Partial Mirror Mode Mirror TAD0 Enable Mirror...

Page 116: ...ble at End of POST Patrol Scrub Interval Selects the number of hours 1 24 required to complete full scrub A value of zero means auto 24 3 3 9 4 IIO Configuration Socket0 Configuration Press Enter to b...

Page 117: ...to bring up the Intel AIC Retimer AIC SSD Configuration menu Retimer workaround Enable or disable the retime workaround no yes PCIe Hot Plug Enable Disable PCIe Hot Plug globally no yes PCIe ACPI Hot...

Page 118: ...ort Bifurcation for selected slot s Auto x4x4x4x4 x4x4x8 x8x4x4 x8x8 x16 IOU2 IIO PCIe Port 4 Selects PCIe port Bifurcation for selected slot s Auto x4x4x4x4 x4x4x8 x8x4x4 x8x8 x16 IOU3 IIO PCIe Port...

Page 119: ...mode the BIOS will remove the EXP port if there is no device or errors on that device and the device is not HP capable Disable is used to disable the port and hide its CFG space Auto Disabled Enabled...

Page 120: ...link width that was set by bifurcation Auto x1 x2 x4 x8 x16 PCIE Port DeEmphasis De Emphasis control LNKCON2 6 for this PCIe port 6 0 dB 3 5 dB PCI E ASPM Support This option enables disables the ASP...

Page 121: ...Opt In Flag Enable Disable DMA_CTRL_PLATFORM_OPT_IN _FLAG in DMAR table in ACPI Not compatible with Direct Device Assignment DDA Enabled Disabled Interrupt Remapping Enable Disable VT_D Interrupt Rema...

Page 122: ...http www tyan com 122 3 3 9 4 3 Intel VMD Technology...

Page 123: ...e VMD in this Stack Disabled Enabled VMD Config for IOU0 Enable Disable VMD in this Stack Disabled Enabled VMD Config for IOU1 Enable Disable VMD in this Stack Disabled Enabled VMD Config for IOU2 Ena...

Page 124: ...rride IOU0 bifurcation if required Disabled Enabled Intel AIC Retimer AIC SSD HW at Stack2 Announce Intel AIC Retimer AIC SSD HW at stack2 Port2A 2D Override IOUx bifurcation if required Disabled Enab...

Page 125: ...rt5A 5D Override IOUx bifurcation if required Disabled Enabled 3 3 9 5 Advanced Power Management Configuration CPU P State Control P State Control Configuration Sub Menu include Turbo XE and ete Hardw...

Page 126: ...port Dynamic SST PP Select Disabled Enabled Intel SST PP Intel SST PP Select allows user to choose from up to two additional base frequency conditions Base Config 3 Config 4 Energy Efficient Turbo Ene...

Page 127: ...M State Control Hardware P States Disable Hardware choose a P state based on OS Request Legacy P States Native Mode Hardware choose a P state based on OS guidance Out of Band Mode Hardware autonomousl...

Page 128: ...e C State Package C State limit C0 C1 state C2 state C6 non Retention state Auto CPU C6 report Enable Disable CPU C6 ACPI C3 report to OS Disabled Enabled Auto Enhanced Halt State C1E Core C1E auto pr...

Page 129: ...to Fused Value If the value is 0 the fused value will be programmed A value greater than fused TDP value will not be programmed 0 PL1 Time Window PL1 value in seconds The value may vary from 0 to 448...

Page 130: ...0 to Fused Value If the value is 0 BIOS programs 125 TDP 0 PL2 Time Window PL2 value in seconds The value may vary from 0 to 448 Indicates the time window over which TDP value should be maintained If...

Page 131: ...1 Server ME Configuration Altitude The altitude of the platform location above the sea level expressed in meters The hex number is decoded as 2 s complement signed integer Provide the 8000h value if t...

Page 132: ...http www tyan com 132 3 3 12 SATA Configuration SATA Configuration SATA devices and settings SSATA Configuration sSATA devices and settings...

Page 133: ...d Configure SATA as Identify the SATA port is connected to Solid State Drive or Hard Disk Drive AHCI RAID Support Aggressive Link Power Management Enables Disables SALP Disabled Enabled Port 0 1 2 3 4...

Page 134: ...be performed and only the drives witch have this option enabled will spin up at boot Otherwise all drives spin up at boot Disabled Enabled SATA Device Type Identify the SATA port is connected to Solid...

Page 135: ...as eSATA Configures port as External SATA eSATA Disabled Enabled Spin Up Device If enabled for any of ports Staggered Spin Up will be performed and only the drives witch have this option enabled will...

Page 136: ...nfiguration PCH Devices Enable Disable Intel IO Controller Hub devices PCI Express Configuration PCI Express Configuration settings USB Configuration USB Configuration Settings ADR Configuration Autom...

Page 137: ...http www tyan com 137 3 3 13 1 PCH Devices PCH state after G3 Select S0 S5 for ACPI state after a G3 S0 S5 Leave power state unchanged...

Page 138: ...http www tyan com 138 3 3 13 2 PCI Express Configuration PCI Express Root Port 1 20 PCI Express Root Port 1 20 Settings...

Page 139: ...xpress Root Port 1 20 Control the PCI Express Root Port Disabled Enabled L1 Substates PCI Express L1 Substates settings Disabled L1 1 L1 2 L1 1 L1 2 PCIe Speed Configure PCIe Speed Auto Gen1 Gen2 Gen3...

Page 140: ...140 3 3 13 3 USB Configuration XHCI Idle L1 Enabled XHCI Idle L1 Disabled to workaround USB3 hot plug will fail after 1 hot plug removal Please put the system to G3 for the new settings to take effect...

Page 141: ...Platform POR Enabled Disabled ADR GPIO Select between GPIO_B or GPIO_C GPIO_B GPIO_C Host Partition Reset ADR Enable Enables Disables ADR on Host Partition Reset Platform POR Enabled Disabled Enable...

Page 142: ...s is a workaround for OSes without XHCI hand off support The XHCI ownership change should be claimed by XHCI driver Disabled Enabled USB Mass Storage Driver Support Enable Disable USB Mass Storage Dri...

Page 143: ...ual SanDisk Mass storage device emulation type AUTO enumerates devices according to their media format Optical drives are emulated as CDROM drives with no media will be emulated according to a drive t...

Page 144: ...www tyan com 144 3 3 15 NVMe Configuration This page shows the Device Name you installed Press Enter to read the device information If no NVME device is installed it shows no NVME device is found Read...

Page 145: ...nction Enabled Disabled Onboard LAN I210 LAN Enable Disable control function Enabled Disabled ICC Clock Spread Spectrum Turn on off Spread Spectrum Setting for IsCLK Enabled Disabled Chassis Intrusion...

Page 146: ...ace Configuration Redfish Enable Disable AMI Redfish Enabled Disabled Authentication mode Select authentication mode Basic Authentication Session Authentication IP address Enter IP address IP Mask add...

Page 147: ...tems are available when Network Stack is set to Enabled Ipv4 PXE Support Enable Ipv4 PXE Boot Support If disabled IPV4 PXE boot option will not be created Disabled Enabled Ipv4 HTTPS Support Enable Ip...

Page 148: ...Enable Ipv6 HTTP Boot Support If disabled IPV6 HTTP boot option will not be created Disabled Enabled PXE boot wait time Wait time to press ESC key to abort the PXE boot 0 Media detect count Number of...

Page 149: ...eed NOTE Change the Fan Speed Control BIOS setting from Manual to Full Speed when installing the Nvidia GeForce Quardro GPU and any VGA card PWM Minimal Duty Cycle PWM Minimal Duty Cycle 30 NOTE This...

Page 150: ...150 3 3 19 1 Sensor Data Register Monitoring When you enter the Sensor Data Register Monitoring submenu you will see the following dialog window pop out Please wait 8 10 seconds NOTE 1 SDR can not be...

Page 151: ...http www tyan com 151...

Page 152: ...http www tyan com 152...

Page 153: ...ADR Enables the detecting and enabling of ADR This is not available if eADR is enabled since eADR requires ADR to be enabled Enabled Disabled Assert ADR on Reset Assert ADR on Reset Enabled Disabled A...

Page 154: ...U Registration Sign up the current CPU This item support INTEL CPU sign the CPU will record current CPU Once BIOS checked different with registered CPU show WARNING message on POST screen Deregistrati...

Page 155: ...3 22 Memory Registration Sign up the current Memory Sign the Memory will record current Memory Once BIOS checked different with registered Memory show WARNING message on POST screen Deregistration Sig...

Page 156: ...http www tyan com 156 3 3 23 Tls Auth Configuration Server CA Configuration Press Enter to configure Server CA Client Cert Configuration Press Enter to configure Client Cert...

Page 157: ...http www tyan com 157 3 3 23 1 Server CA Configuration Enroll Cert Press Enter to enroll cert Delete Cert Press Enter to delete cert...

Page 158: ...nroll Cert Enroll Cert Using File Enroll Cert Using File Cert GUID Input digit character in 11111111 2222 3333 4444 1234567890ab format Commit Changes and Exit Commit Changes and Exit Discard Changes...

Page 159: ...http www tyan com 159 3 3 23 1 2 Delete Cert FE9C6606 8B49 44A3 8B6B DEA3A0E032 GUID for CERT Disabled Enabled...

Page 160: ...http www tyan com 160 3 3 24 iSCSI Configuration Host iSCSI Configuration Host iSCSI Configuration...

Page 161: ...nitiator Only IQN format is accepted Enter iqn xxx xxx ranges from 4 to 223 Add an Attempt Add an Attempt Delete Attempts Delete one or more attempts Change Attempt Order Change the order of Attempts...

Page 162: ...http www tyan com 162 3 3 24 1 1 Add an Attempt NOTE Only LAN1 supports iSCSI function MAC xx xx xx xx xx xx Intel I210 Gigabit Network Connection PFA Bus 2 Dev 0 Func 0...

Page 163: ...iSCSI Mode Disabled Enabled Enabled for MPIO Disabled Enabled Enabled for MPIO Internet Protocol Initiator IP address is system assigned in IP6 mode In Autoconfigure mode iSCSI driver will attempt to...

Page 164: ...al notation Initiator Subnet Mask Enter IP address in dotted decimal notation Gateway Enter IP address in dotted decimal notation Target Name The worldwide unique name of the target Only iqn format is...

Page 165: ...PFA Bus 2 Dev 0 Func 0 iSCSI mode Disabled IP version IPv4 Disabled Enabled Attempt 2 MAC xx xx xx xx xx xx PFA Bus 2 Dev 0 Func 0 iSCSI mode Disabled IP version IPv4 Disabled Enabled Commit Changes a...

Page 166: ...t Order Change the order of Attempts using keys Use arrow keys to select the attempt then press to move the attempt up down in the attempt order list Attempt 1 Attempt 2 Commit Changes and Exit Commit...

Page 167: ...http www tyan com 167 3 3 24 VLAN Configuration MAC xxxxxxxxxxxx Enter Configuration Menu Press ENTER to enter configuration menu for VLAN configuration...

Page 168: ...24 1 Enter Configuration Menu VLAN ID VLAN ID of new VLAN or existing VLAN valid value is 0 4094 Priority 802 1Q Priority valid value is 0 7 Add VLAN Create a new VLAN or update existing VLAN Remove V...

Page 169: ...www tyan com 169 3 3 24 MAC xxxxxxxxxxxx IPv4 Network Configuration Configured Indicate whether network address configured successfully or not Disabled Enabled Save Changes and Exit Save Changes and...

Page 170: ...http www tyan com 170 3 3 25 MAC xxxxxxxxxxxx IPv6 Network Configuration Enter Configuration Menu Press ENTER to enter configuration menu for IPv6 configuration...

Page 171: ...utive Neighbor Solicitation messages sent while performing Duplicate Address Detection on a tentative address A value of zero indicates that Duplicate Address Detection is not performed 1 Policy Autom...

Page 172: ...ges and Exit 3 3 26 Intel I210 Gigabit Network Connection Configuration Firmware Image Properties View device firmware version information NIC Configuration Click to configure the network device port...

Page 173: ...http www tyan com 173 3 3 26 1 Firmware Image Properties Configuration...

Page 174: ...lf 10 Mbps Full 100 Mbps Half 100Mbps Full Wake On LAN Specifies the port speed used for the selected boot protocol Enables power on of the system via LAN Note that configuring Wake on LAN in the oper...

Page 175: ...ayed in this page may vary in accordance with the cards you installed Intel PRO 1000 9 4 06 PCI E Provides Health Status for the Drivers Controllers Healthy Intel 10GbE Driver 7 8 13x64 Provides Healt...

Page 176: ...ot of the Driver Health The information displayed here may vary in accordance with the card you installed Controller 6161BB18 Child 0 Provides Health Status for the Drivers Controllers Healthy Intel I...

Page 177: ...Driver Health The information displayed here may vary in accordance with the card you installed Controller 6125FD98 Child 0 Provides Health Status for the Drivers Controllers Healthy Intel Ethernet Co...

Page 178: ...3 3 27 3 Intel 10GbE Driver Controller 6125E898 Child 0 Provides Health Status for the Drivers Controllers Healthy Intel Ethernet Converged Network Adapter X550 T2 Provides Health Status for the Drive...

Page 179: ...Enabled Disabled NOTE When FRB 2 Timer was set to Enabled the following 3 items will be available FRB 2 Timer timeout Enter value Between 3 to 6 min for FRB 2 Timer Expiration value 6 FRB 2 Timer Poli...

Page 180: ...hen OS Watchdog Timer was set to Enabled the following 2 items will be available OS Wtd Timer timeout Configure the length of the OS Boot Watchdog Timer Not available if OS Boot Watchdog timer is disa...

Page 181: ...on will not modify any BMC network parameters during BIOS phase Unspecified Static DynamicBmcDhcp DynamicBmcNonDhcp Management Port 2 Enable Disable BMC Share Nic Enabled Disabled Configuration Addres...

Page 182: ...com 182 Configure IPV6 Support Server Management Port 1 IPV6 Support Enable or Disable LAN1 IPV6 Support Enabled Disabled Server Management Port 2 IPV6 Support Enable or Disable LAN1 IPV6 Support Ena...

Page 183: ...the Confirm New Password window will pop out to ask for confirmation User Password Set user password in the Create New Password window After you key in the password the Confirm New Password window wil...

Page 184: ...dard Custom In Custom mode Secure Boot Variables can be configured without authentication Standard Custom NOTE When Secure Boot Mode was set to Custom the following items will be available to change R...

Page 185: ...Force System to User Mode Install Factory Default Secure Boot key databases Reset To Setup Mode Delete all Secure Boot key database from NVRAM Export Secure Boot variables Copy NVRAM content of Secure...

Page 186: ...t Details Export Update Delete Key Exchange Keys Enroll Factory Defaults or load certificates from a file 1 Public Key Certificate in a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER encoded c EFI_CERT_RSA204...

Page 187: ...efaults or load certificates from a file 1 Public Key Certificate in a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER encoded c EFI_CERT_RSA2048 bin d EFI_CERT_SHA256 384 512 bin 2 Authenticated UEFI Variable...

Page 188: ...s indefinite waiting 1 Bootup NumLock State Select the keyboard NumLock state Off On Quiet Boot Enable or disable Quiet Boot option Disabled Enabled Endless Boot Support Enables or disables Endless Bo...

Page 189: ...oot Option Priorities Boot Option 1 2 Select the first second boot device Device Name Disabled Add New Boot Option Add a new EFI boot option to the boot order Delete Boot Option Remove an EFI boot opt...

Page 190: ...any changes Save Changes and Reset Reset the system after saving the changes Discard Changes and Reset Reset system setup without saving any changes Save Changes Save changes done so far to any of th...

Page 191: ...http www tyan com 191 Save as User Defaults Save the changes done so far as User Defaults Restore User Defaults Restore the User Defaults to all the setup options Boot Override Read only...

Page 192: ...nt shall Tyan be liable for direct indirect incidental special or consequential damages arising from the BIOS update or recovery The BIOS Recovery file is named xxxx cap where the xxxx portion is the...

Page 193: ...t the server during the BIOS recovery process This can damage the BIOS recovery bootloader and prevent it from loading a subsequent time 7 Wait for the BIOS recovery procedure to complete Completion i...

Page 194: ...o S5642 MB M1309F65T Connect to S5642 M B Mini SAS HD Cable 1 CN10 PCH_SATA_0_7 P N 422T51400004 Mini SAS HD Cable 2 CN11 PCH_SATA_0_7 P N 422T53400017 Fan Ctrl Cable J4 FAN_HD1 P N 422T53400003 3 Sli...

Page 195: ...t to M1309F65T BP12 8 2x4P PWR Cable P19 VGA PCI E J6 2x4P PWR Cable P20 VGA PCI E J7 6 4P 2 5 HDD BP PWR Cable PSU to M1298T65 BP12E 2 PSU Connect to M1298T65 BP12E 2 4P PWR Cable P21 PW1 7 System Re...

Page 196: ...d for readers reference Figure 1 Sensor Location NOTE The red spot indicates the sensor Fan and Temp Sensor Location 1 Fan Sensor It is located in the third pin of the fan connector which detects the...

Page 197: ...http www tyan com 197 BIOS Temp Sensor Name Explanation...

Page 198: ...http www tyan com 198...

Page 199: ...MC2_CH_D Temperature of CPU0 DIMM Channel D P0_UMC6_CH_E Temperature of CPU0 DIMM Channel E P0_UMC7_CH_F Temperature of CPU0 DIMM Channel F P0_UMC5_CH_G Temperature of CPU0 DIMM Channel G P0_UMC4_CH_H...

Page 200: ...20 120 38mm 6PIN Rear FAN module FRU TH 0400 336210000065 80 80 38mm 4 PIN rack mount FRU kit FRU AS 9230 5412T6320006 FT65T B5642 SLIDE RAIL KIT HANDLE R HANDLE L Cable FRU CS 0500 422T51400004 450 m...

Page 201: ...http www tyan com 201 NOTE...

Page 202: ...expectations TYAN s website http www tyan com provides easy to access resources such as in depth Linux Online Support sections with downloadable Linux drivers and comprehensive compatibility reports...

Page 203: ...roper maintenance of products NOTE A receipt or copy of your invoice marked with the date of purchase is required before any warranty service can be rendered You may obtain service by calling the manu...

Reviews: