background image

  

                                                       

http://www.tyan.com

 

64 

4.2      Installing the Nvidia

®

 K20 GPU card 

 

1.  Release to take out the GPU bracket.   

     

 

2.  Install the NVIDIA

®

 K20 GPU card to the GPU bracket.   

 

 

3.  Insert the NVIDIA® K20 GPU card onto the M7102T76-R16-2F riser card 

and rotate the red circle button clockwise to lock the bracket. 

     

 

Summary of Contents for TN76-B7102

Page 1: ...1 http www tyan com TN76 B7102 Service Engineer s Manual ...

Page 2: ...2 http www tyan com ...

Page 3: ...ding liability or warranties relating to fitness for a particular purpose or merchantability MiTAC retains the right to make changes to produce descriptions and or specifications at any time without notice In no event will MiTAC be held liable for any direct or indirect incidental or consequential damage loss of use loss of data or other malady resulting from errors or inaccuracies of information ...

Page 4: ...ses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Notice for Canada This Class A digital apparatus comp...

Page 5: ...ponents Chapter 4 Installing GPU Card This chapter introduce how to installing the GPU Card and list how many kinds GPU Cards are suitable for TN76 B7102 chassis Chapter 5 Mainboard Information This chapter lists the hardware setup procedures that you need to abide by when installing system components It includes description of the jumpers and connectors on the motherboard Chapter6 BIOS Setup This...

Page 6: ... the purpose of this pin If your outlet does not support this kind of plug contact your electrician to replace your obsolete outlet Do not place anything on the power cord Place the power cord where it will not be in the way of foot traffic Follow all warnings and cautions in this manual and on the unit case Do not push objects in the ventilation slots as they may touch high voltage components and...

Page 7: ...e before you install operate or service TYAN products Symbols on Equipment Caution This symbol indicates a potential hazard The potential for injury exists if cautions are not observed Consult equipment documentation for specific details Caution Slide mounted equipment is not to be used as a shelf or a work space Warning This symbol indicates the presence of hazardous energy circuits or electric s...

Page 8: ...uct in a wet location Equipment Chassis Do not block or cover the openings to the system Never push objects of any kind through openings in the equipment Dangerous voltages might be present Conductive foreign objects can produce a short circuit and cause fire electric shock or damage to your equipment Lift equipment using both hands and with your knees bent Equipment Racks To avoid injury or damag...

Page 9: ...depth must allow for proper serviceability and cable management Ensure that there is adequate airflow in the rack Improper installation or restricted airflow can damage the equipment The rack cannot have solid or restricted airflow doors You must use a mesh door on the front and back of the rack or remove the doors to ensure adequate air flow to the system If you install the Model in a rack do not...

Page 10: ...ipment Batteries The system battery contains lithium manganese dioxide If the battery pack is not handled properly there is risk of fire and burns Do not disassemble crush puncture short external contacts or dispose of the battery in fire or water Do not expose the battery to temperatures higher than 60 C 140 F The system battery is not replaceable If the battery is replaced by an incorrect type t...

Page 11: ...ching internal components Do not use conductive tools that could bridge live parts Use gloves when you remove or replace system components they can become hot to the touch If the product sustains damage requiring service disconnect the product from the AC electrical outlet and refer servicing to an authorized service provider Examples of damage requiring service include The power cord extension co...

Page 12: ...1 3 Installing the CPU Heatsink 25 2 1 4 Installing the Memory 29 2 1 5 Installing Hard Drives 31 2 2 Rack Mounting 34 2 2 1 Installing the Server in a Rack 34 2 2 2 Installing the inner Rails to the Chassis 34 2 2 3 Installing the Outer Rails to the Rack 36 2 2 4 Rack mounting the Server 37 Chapter 3 Replacing Pre Installed Components 38 3 0 1 Introduction 38 3 0 2 Disassembly Flowchart 38 3 1 Re...

Page 13: ...rmation 65 5 1 Board Image 66 5 2 CPU Chipset PCIe 67 5 3 Block Diagram 68 5 4 Mainboard Mechanical Drawing 69 5 5 Board Parts Jumpers and Connectors 70 5 6 Tips on Installing Motherboard in Chassis 77 5 7 Memory 78 5 8 Power Supply 80 Chapter 6 BIOS Setup 83 6 1 About the BIOS 83 6 2 Main Menu 85 6 3 Advanced Menu 87 6 4 Platform Configuration Menu 115 6 5 Socket Configuration 127 6 6 Server Mana...

Page 14: ...and 64 bit computing high bandwidth memory design and lightning fast PCI E bus implementation The TN76 B7102 not only empowers your company in nowadays IT demand but also offers a smooth path for future application usage TYAN also offers the TN76 B7102 in a version that can support up to twelve 3 5 2 5 fixed hard drives The TN76 B7102 uses TYAN s latest chassis featuring a robust structure and a s...

Page 15: ...num Redundancy 1 1 Processor Socket Type Q ty LGA3647 2 Supported CPU Series Intel Xeon Processor Scalable Family Thermal Design Power TDP wattage Max up to 165W System Bus Up to 10 4 9 6 GT s with Intel UltraPath Interconnect UPI support Chipset Chipset Intel C621 Memory Supported DIMM Qty 12 12 DIMM slots DIMM Type Speed DDR4 RDIMM RDIMM 3DS LRDIMM LRDIMM 3DS 2666 Capacity Up to 768GB RDIMM 1 53...

Page 16: ...r Others Watchdog timer support Server Management Onboard Chipset Onboard Aspeed AST2500 AST2500 iKVM Feature IPMI 2 0 compliant baseboard management controller BMC Supports storage over IP and remote platform flash USB 2 0 virtual hub AST2500 IPMI Feature 24 bit high quality video compression 10 100 1000 Mb s MAC interface BIOS Brand ROM size AMI 32MB Feature PXE boot support ACPI 5 0 SMBIOS 3 0 ...

Page 17: ...alled 6 System Fans 1 M1271T71 BP12 12 pre installed 1 M1715T71 FPB pre installed 1 M1714T71 USB pre installed 2 M7102T76 L16 2F Riser card pre installed 1 M7102T76 R16 2F Riser card pre installed 1 4 2 Accessories If any items are missing or appear damaged contact your retailer or browse to TYAN s website for service http www tyan com The web site also provides information of other TYAN products ...

Page 18: ... SSD Sequence HDD SSD2 HDD SSD5 HDD SSD8 HDD SSD11 HDD SSD1 HDD SSD4 HDD SSD7 HDD SSD10 HDD SSD0 HDD SSD3 HDD SSD6 HDD SSD9 No Description 1 USB3 0 Port 2 Front Panel Board 3 Power On Off Button with green LED 4 ID Button 5 ID LED blue color 6 FAULT LED amber color 7 12 3 5 2 5 SATA 6G SAS12G hot swap HDDs SSDs ...

Page 19: ...ff Off System works fine Power LED On Green System powered on Blinking Green System standing by Off Off System AC off HDD SSD LED Definitions LED Drive State Activity LED Green color Status LED Orange color Drive Present No Activity Solid On Off Drive Present with Activity Blinking Off Drive Fail Don t care Solid On Drive identify Don t care Blinking 1Hz Drive Rebuild Don t care Blinking 4Hz ...

Page 20: ...pansion Slots 3 Expansion Slots 4 1 1 ERP1U 1200 RPSU 80 Platinum Power Supply 5 VGA Port 6 Serial Port 7 RJ 45 Connector LAN2 8 RJ 45 Connector LAN1 9 SFP2 SFP1 interface from mezzanine card 10 1 x HH HL PCIE Slot 11 ID LED ID LED SW 12 RJ 45 Connector LAN3 Dedicated IPMI upper USB 3 0 ports x 2 down ...

Page 21: ... No Description 1 4 3 5 2 5 SAS12G SATA6G hot swap HDDs SSDs 2 HDD Backplane Board 3 Memory Slots 4 CPU Sockets 5 6 7 GPU Card assembly 1 1 1000W 110Vac 1600W 220Vac Power Supply underneath NOTE The system is pre installed with S7102 mainboard ...

Page 22: ...per tools can prevent you from accidentally damaging the internal components 2 0 3 Tools The following procedures require only a few tools including the following A cross head Phillips screwdriver A hex wrench A grounding strap or an anti static pad Most of the electrical and mechanical connections can be disconnected with your hands It is recommended that you do not use pliers to remove connector...

Page 23: ...id touching motherboard components IC chips connectors memory modules and leads The motherboard is pre installed in the system When removing the motherboard always place it on a grounded anti static surface until you are ready to reinstall it Hold electronic circuit boards by the edges only Do not touch the components on the board unless it is necessary to do so Do not flex or stress circuit board...

Page 24: ...ard including CPU heatsink air duct memory modules HDD SSD and LAN Card 2 1 1 Removing the Chassis Cover Follow these instructions to remove the TN76 B7102 chassis cover 1 Unscrew the top cover 2 Slide the top cover off and remove the top cover from the chassis 2 1 2 Removing the Air Duct 1 Remove the air duct from the chassis ...

Page 25: ...e CPU Heatsink There are two kinds of CPU supported in Purley Platform Intel Socket P S7102 Fabric CPU Non Fabric CPU Follow the steps below on installing the process heatsink and air duct 1 Locate the CPU socket 2 Take out the protection cap ...

Page 26: ...Put the Narrow Fabric processor on the Carrier hook clips 2 Align and install the processor on the carrier 3 Carefully flip the heatsink Then install the carrier assembly on the bottom of the heatsink and make sure Carrier hook clips is stuck in the heatsink ...

Page 27: ... guide pins and make sure the gold arrow is located in the correct direction Then place the heatsink onto the top of the CPU socket 6 To secure the heatsink use a T30 Security Torx to tighten the screws in a sequential order 1 2 3 4 When disassembling the heatsink loosen the screws in reverse order 4 3 2 1 ...

Page 28: ...ic CPU 1 Put the Narrow Fabric processor on the Carrier hook clips 2 Align and install the processor on the carrier 3 Insert the Fabric CPU Carrier hook clips onto the heatsink 4 The same procedure as non Fabric CPU installation step 4 to step 6 ...

Page 29: ...http www tyan com 29 2 1 4 Installing the Memory Memory population table ...

Page 30: ... the direction of the arrows as shown in the following illustration Always start at CPU0_DIMM_A0 2 Align the memory module with the slot When inserted properly the memory slot locking levers lock automatically onto the indentations at the ends of the module Follow the recommended memory population table to install the other memory modules ...

Page 31: ...lling Hard Drives Follow these instructions to install 12 3 5 2 5 hard drives Warning Always install the hard disk drive to the chassis after the chassis is secured on the rack HDD Trays 1 Push the latch to pull the hard disk tray out ...

Page 32: ... 2 Option 1 3 5 HDD Place a 3 5 hard drive into the HDD tray and secure the HDD with 4 HDD screws 3 Option 2 2 5 HDD SSD Place a 2 5 hard drive into the HDD tray Turn the HDD tray over and secure the HDD SSD with 4 screws ...

Page 33: ...http www tyan com 33 4 Reinsert the HDD tray into the chassis ...

Page 34: ... Server in a Rack Follow these instructions to mount the TYAN TN76 B7102 into an industry standard 19 rack NOTE Before mounting the TYAN TN76 B7102 in a rack ensure that all internal components have been installed and that the unit has been fully tested However to make the installation easier we suggest that you remove all HDD trays before you insert the chassis into the rack 2 2 2 Installing the ...

Page 35: ...http www tyan com 35 4 Screw the inner rail to the chassis ...

Page 36: ...www tyan com 36 5 Align and screw the inner sliding rail on the other side of the server 2 2 3 Installing the Outer Rails to the Rack 1 Secure the outer rails to the rack 2 Screw the outer rails to the rack ...

Page 37: ...an com 37 2 2 4 Rack mounting the Server 1 Lift the unit and then insert the inner slide rails into the middle rails 2 Push the whole system into the rack 3 Secure the whole system to the rack with 2 thumb screws ...

Page 38: ...ns how to replace the pre installed components including the S7102 Motherboard M1271T71 BP12 12 12 Ports 6G 12G HDD Backplane Board M1715T71 FPB Front Panel Board MP016T76 Fan Board System Fan and Power Supply Unit etc 3 0 2 Disassembly Flowchart The following flowchart outlines the disassembly procedures ...

Page 39: ...move the cover of the TN76 B7102 3 2 Replacing Motherboard Components Follow these instructions to replace motherboard components including the motherboard 3 2 1 Disconnecting All Motherboard Cables Before replacing the motherboard or certain components remove cables connected to the motherboard Follow these instructions to remove all cables 1 Disconnect all cables ...

Page 40: ...supplies air ducts processor and heatsink with thermal pad attached accordingly NOTE DO NOT remove the thermal pad from the heatsink If the thermal pad is broken please order a new heatsink FRU and follow the instruction stated in Section 2 1 3 Installing the CPU Heatsink page 25 2 Remove the 12 screws securing the motherboard to the chassis 3 Carefully lift the motherboard from the chassis ...

Page 41: ...board inside the chassis and align the screw holes of the motherboard to the studs inside the case If there are any studs missing you will know right away since the motherboard will not be able to be securely installed 5 NOTE Be especially careful to look for extra stand offs If there are any stand offs present that are not aligned with a mounting hole on the motherboard it will likely short compo...

Page 42: ... 3 Replacing the HDD Backplane Board Follow these instructions to replace the M1271T71 BP12 12 12 Ports HDD Backplane Board 1 Pull all front HDD trays out 2 Disconnect the power cable 3 Disconnect the 3pcs Mini SAS HD cable ...

Page 43: ...http www tyan com 43 4 Loose the screws on both sides of the chassis 5 Take out the HDD BP board ...

Page 44: ...http www tyan com 44 6 Release 8 push pins to lift the mylar 7 Loose ten screws to replace with a new HDD BP Board 8 Reinstall the HDD BP Board into the chassis following the steps in reverse ...

Page 45: ...tor W429 8 x L78 4 mm 8 layer PCB Specifications 12 SAS SATA HDD SSD Connector connected to HDD SSD SAS0 11 3 Mini SAS HD Connector connected to MB MINI_SAS0 2 1 12 pin Power Connector connected to MB PW5 1 30 pin Fan Connector connected to MB J36 5 6 pin Fan Connector connected to Fan FAN1 5 LEDs 12 HDD SSD Active LEDs 12 HDD SSD Fault LEDs ...

Page 46: ... Pin Definition FAN_TACH1 1 2 FAN_TACH6 FAN_TACH2 3 4 FAN_TACH7 FAN_TACH3 5 6 FAN_TACH8 FAN_TACH4 7 8 FAN_TACH9 FAN_TACH5 9 10 FAN_TACH10 GND 11 12 GND CON_PWM2 13 14 CON_PWM1 FAN_TACH11 15 16 KEY FAN_TACH12 17 18 KEY KEY 19 20 CON_PWM3 KEY 21 22 GND FAN_TACH13 23 24 FAN_TACH15 FAN_TACH14 25 26 FAN_TACH16 CON_PWM4 27 28 CON_PWM6 GND 29 30 GND FAN1 FAN5 6 pin FAN Connector Definition Pin Pin Defini...

Page 47: ...uctions to replace the M1715T71 FPB Front Panel Board 1 Unscrew the front panel bezel 2 Take out the front panel bezel and unscrew the Front Panel Board 3 Disconnect the Front Panel control cable 4 Reinstall the Front Panel Board into the chassis following the steps in reverse ...

Page 48: ... green color Power LED J3 1 ID Button SW1 1 blue color ID LED LED_ID1 1 orange color FAULT LED LED_FAULT1 3 4 2 Connector Pin Definitions J1 Front Panel Board Connector Definition Pin Pin Definition FP_PW_LED_PW 1 11 FP_PWR_BTN_N VCC_FPB 2 12 NC NC 3 13 GND FP_ID_LED_PW 4 14 NC FP_PW_LED_GND 5 15 NC FP_ID_LED_N 6 16 FP_SMB_DAT NC 7 17 GND BMC_HW_FAULT_N 8 18 FP_SMB_CLK NC 9 19 FP_IDLED_BTN_N BMC_S...

Page 49: ...com 49 3 5 Replacing the USB Board Follow these instructions to replace the M1714T71 USB USB Board 1 Unscrew 4 screws to release the USB board bezel 2 Take out the USB Board bezel 3 Disconnect the Front USB3 0 Cable ...

Page 50: ...om 50 4 Unscrew the USB Board bracket 5 Slide to take out the USB Board bracket 6 Unscrew the USB Board to replace with a new one 7 Reinstall the USB Board bracket into the chassis following the steps in reverse order ...

Page 51: ...www tyan com 51 3 6 Replacing the Fans Follow these instructions to replace the fans 1 Take out the fan module from the chassis 2 Replace the failed fan module with a new one 3 Loose the screws on both sides ...

Page 52: ...yan com 52 4 Push the latch in the direction as the arrow shown to release the fan from the iron holder 5 Remove the iron holder to replace a new fan Follow the procedure reverse order to reinstall the system fan ...

Page 53: ...http www tyan com 53 3 7 Replacing the Fan Board Follow these instructions to replace the MP016T76 FB Fan Board 1 Take out the fan modules 2 Remove the six screws 3 Take out the fan chassis ...

Page 54: ...http www tyan com 54 4 Disconnect the fan cable and fan power cable 5 Remove the 8 screws ...

Page 55: ...d in details Front view Rear view Form Factor W389 5 x L54 mm 4 layer PCB Specifications 12 FAN Connector 2 Power Connector J2 J5 2 FAN Cable Connector J1 J6 LEDs 12 Fan Fail LEDs 3 7 2 Fan Board LED Definition FAN Status Upper LED lower LED Normal On Green On Green Abnormal Red Red ...

Page 56: ... SYS_FAN9_TACH PIN 9 PIN 10 PIN 11 PIN 12 SYS_FAN5_TACH SYS_FAN10_TACH GND GND PIN 13 PIN 14 PIN 15 PIN 16 PWM_SYS2 PWM_SYS1 SYS_FAN11_TACH NA PIN 17 PIN 18 PIN 19 PIN 20 SYS_FAN12_TACH NA VCC3_AUX PWM_SYS3 PIN 21 PIN 22 PIN 23 PIN 24 VCC3_AUX GND NA NA PIN 25 PIN 26 PIN 27 PIN 28 NA NA PWM_SYS4 PWM_SYS5 PIN 29 PIN 30 PWM_SYS6 GND FAN Connector FAN1 FAN12 FAN1 FAN12 FAN Connector PIN 1 PIN 2 PIN 3...

Page 57: ...2 has three pre installed PCI E riser cards Follow the instructions below to disassemble the M7102T76 R16 2F and M7102T76 L16 2F riser cards Uninstalling the M7102T76 L16 2F riser card 1 There are three GPU brackets in the TN76 B7102 chassis 2 lift the GPU assembly up ...

Page 58: ...place a new one if necessary Uninstalling the M7102T76 R16 2F riser card 1 Follow the same procedure to detach the other GPU assembly Unscrew the M7102T76 R16 1F riser card to replace a new one if necessary 2 Follow the steps described earlier in reverse to reinstall the M1202 L16 1F riser card ...

Page 59: ...http www tyan com 59 3 8 1 PCIE Riser card Features M7102T76 R16 2F riser card M7102T76 L16 2F riser card ...

Page 60: ... installed Power Supply Units Please unplug the power cord before you follow these instructions to replace the power supply units 1 Press the latch to pull the power supply out 2 After replacing a new power supply press the latch to push the power supply back into the chassis ...

Page 61: ...will introduce you how to install the GTX GPU card 4 1 Installing the GTX GPU card The TN76 B7102 supports three PCI E Riser Card Brackets A power cable 2x4p is required for GPU cards Follow these instructions to install GPU card in your system Combine with the B7102T76V12HR 2T G IO 1 TN76 B7102 equips 3 GPU card assembly and lift the bracket up ...

Page 62: ...screws secure the PCI bracket 3 Pull the two PCI bracket out The GTX GPU card needs two bracket s space 4 Insert the GTX GPU card onto the M7102T76 L16 2F riser card and secure with 2 screws on the expansion slot and connect the GPU cable ...

Page 63: ...ww tyan com 63 5 Put the PCI bracket back to the chassis and connect the power cable NOTE MP016T76 L16 1F riser card should combine with the Rear I O shielding And the riser card should insert in PCIe Slot 2 ...

Page 64: ...Nvidia K20 GPU card 1 Release to take out the GPU bracket 2 Install the NVIDIA K20 GPU card to the GPU bracket 3 Insert the NVIDIA K20 GPU card onto the M7102T76 R16 2F riser card and rotate the red circle button clockwise to lock the bracket ...

Page 65: ...fest conditions MiTAC recommends wearing a static safety wrist strap 2 Hold the motherboard by its edges and do not touch the bottom of the board or flex the board in any way 3 Avoid touching the motherboard components IC chips connectors memory modules and leads 4 Place the motherboard on a grounded antistatic surface or on the antistatic bag that the board was shipped in 5 Inspect the board for ...

Page 66: ...ttp www tyan com 66 5 1 Board Image S7102 This picture is representative of the latest board revision available at the time of publishing The board you receive may not look exactly like the above picture ...

Page 67: ...http www tyan com 67 5 2 CPU Chipset PCIe ...

Page 68: ...http www tyan com 68 5 3 Block Diagram B7102 Block Diagram ...

Page 69: ...http www tyan com 69 5 4 Mainboard Mechanical Drawing ...

Page 70: ...sion available at the time of publishing The board you receive may not look exactly like the above diagram The DIMM slot numbers shown above can be used as a reference when reviewing the DIMM population guidelines shown later in the manual For the latest board revision please visit our web site at http www tyan com ...

Page 71: ...Module Header DBG_HD1 12 SATA Connector PCH_SATA_0123 30 SSATA DOM Connector SSATA_DOM5 13 SSATA Connector PCH_SSATA_0123 31 Power Button PWR_BTN1 14 SSATA DOM Connector SSATA_DOM4 32 Reset Button RST_BTN1 15 ID LED ID_LED1 33 System FAN Connector FAN_HD1 16 ID LED Button ID LED_BTN1 34 VROC Header J51 17 RJ45 LAN1 IPMI and USB Connector USB3_IPMI_LAN1 35 CPU1 FAN Header CPU1_FAN_1 18 Clear Button...

Page 72: ...LED 7 8 HWM_FAULT_LED HD_LED 9 10 SYS_FAULT_LED PW_SW 11 12 LAN1_ACTLED GND 13 14 LAN1_ACTLED RST_SW 15 16 SDA GND 17 18 SCL FP_ID_LED_BTN_N 19 20 INTRUDER FPIO_TEMP_IN 21 22 LAN2_ACTLED NMI_SW 23 24 LAN2_ACTLED HD_COM2 COM2 Header Signal Pin Pin Signal COM2_DCD 1 2 COM2_DSR COM2_RXD 3 4 COM2_RTS COM2_TXD 5 6 COM2_CTS COM2_DTR 7 8 COM2_NRI GND 9 10 KEY IPMB_HD1 IPMB Pin Header Pin 1 2 3 4 Signal I...

Page 73: ...ATA_0123 PCH_SATA_4567 PCH_SSATA_0123 Signal Pin Pin Signal SM_DAT PIN A1 PIN A2 SGPIO _CLK GND PIN A3 PIN A4 SATA6G_RX_P1 SATA6G_RX_N1 PIN A5 PIN A6 GND SATA6G_RX_P3 PIN A7 PIN A8 SATA6G_RX_N 3 GND PIN A9 PIN B1 GND SGPIO _LOAD PIN B2 PIN B3 GND SATA6G_RX_P0 PIN B4 PIN B5 SATA6G_RX_N 0 GND PIN B6 PIN B7 SATA6G_RX_P2 SATA6G_RX_N2 PIN B8 PIN B9 GND SGPIO_SATA_DAT AOUT0 PIN C1 PIN C2 GND GND PIN C3 ...

Page 74: ...ar_BTN1 RTC reset Button for clear CMOS Pin 1 2 3 4 Signal GND GND RST_N RST_N SSATA_SGPIO SSATA SGPIO Header for SSATA0 5 Signal Pin Pin Signal SMBCLK 1 2 SDATA IN SMBDATA 3 4 SDATA OUT GND 5 6 SLOAD KEY 7 8 SCLOCK VCC3_AUX 9 10 NA DOM_5V_PW1 DOM_5V_PW2 SSATA DOM Power Connector Signal Pin Pin Signal GND 1 2 VCC5 TYPEA_USB3 Vertical Type_A USB3 0 Connector Signal Pin Pin Signal 5V 1 2 USB2 0_DATA...

Page 75: ... KEY LAD1 5 6 PLT_RST_N LAD2 7 8 GND LAD3 9 10 CLK_33M DBG_SERIRQ 11 12 CLK DBG_PRES_N 13 14 VCC3_AUX TPM_ADDR_MB 15 16 PCH_TPM_PP_EN FAN_HD1 SYS_FAN Header Signal Pin Pin Signal FAN TACH1 1 2 FAN TACH6 FAN TACH2 3 4 FAN TACH7 FAN TACH3 5 6 FAN TACH8 FAN TACH4 7 8 FAN TACH9 FAN TACH5 9 10 FAN TACH10 GND 11 12 GND FAN PWM2 13 14 FAN PWM1 FAN TACH11 15 16 SMBDATA FAN TACH12 17 18 SMBCLK V3P3_AUX 19 ...

Page 76: ...n Signal GND 1 2 VCC3_AUX GND 3 4 PCH_SATA_RAID_KEY 3PHD_2 ME RECOVERY MODE Jumper Signal Pin Pin Signal NC 1 2 FM_ME_RCVR_N GND 3 1 2 Normal 2 3 ME Recovery mode 3PHD_7 BMC COM Port Debug Jumper Signal Pin Pin Signal BMC_COM2_RXD 1 2 RXD_2 BMC_COM5_RXD 3 1 2 BMC COM2 2 3 BMC COM5 debug 3PHD_8 BMC COM Port Debug Jumper Signal Pin Pin Signal BMC_COM2_TXD 1 2 TXD_2 BMC_COM5_TXD 3 1 2 BMC COM2 2 3 BM...

Page 77: ...lude plastic studs instead of metal Although the plastic studs are usable MiTAC recommends using metal studs with screws that will fasten the motherboard more securely in place Below is a chart detailing what the most common motherboard studs look like and how they should be installed ...

Page 78: ...http www tyan com 78 5 7 Memory DDR4 POR Table ...

Page 79: ... recommended Single CPU Installed CPU0 only Quantity of memory installed 1 2 3 4 5 6 7 8 9 10 11 12 P0_MC0_DIM_CH_A0 P0_MC0_DIM_CH_A1 P0_MC0_DIM_CH_B0 P0_MC0_DIM_CH_B1 P0_MC0_DIM_CH_C0 P0_MC0_DIM_CH_C1 P0_MC1_DIM_CH_D0 P0_MC1_DIM_CH_D1 P0_MC1_DIM_CH_E0 P0_MC1_DIM_CH_E1 P0_MC1_DIM_CH_F0 P0_MC1_DIM_CH_F1 ...

Page 80: ... GND A6 B6 GND GND A7 B7 GND GND A8 B8 GND GND A9 B9 GND 12V_IN A10 B10 12V_IN 12V_IN A11 B11 12V_IN 12V_IN A12 B12 12V_IN 12V_IN A13 B13 12V_IN 12V_IN A14 B14 12V_IN 12V_IN A15 B15 12V_IN 12V_IN A16 B16 12V_IN 12V_IN A17 B17 12V_IN 12V_IN A18 B18 12V_IN PSU1_SDA A19 B19 PSU1_A0 PSU1_SCL A20 B20 PSU1_A1 PSU1_PSON_N A21 B21 12VSB PSU1_ALERT A22 B22 PSU1SMART_ON PSU1_RETURN_S A23 B23 PSU1_12VLS PSU1...

Page 81: ...2V_IN A13 B13 12V_IN 12V_IN A14 B14 12V_IN 12V_IN A15 B15 12V_IN 12V_IN A16 B16 12V_IN 12V_IN A17 B17 12V_IN 12V_IN A18 B18 12V_IN PSU1_SDA A19 B19 PSU1_A0 PSU1_SCL A20 B20 PSU1_A1 PSU1_PSON_N A21 B21 12VSB PSU1_ALERT A22 B22 PSU1SMART_ON PSU1_RETURN_S A23 B23 PSU1_12VLS PSU1_12VS A24 B24 PSU1_PRESENT_N PSU1_PWOK A25 B25 PSU1_PS_KILL HDD_Power1 12 pin Power Connector Signal Pin Pin Signal GND 1 7 ...

Page 82: ... tyan com 82 PE_PW1 PE_PW4 PE_PW2 FAN_PW1 Power Connector for GPU Signal Pin Pin Signal GND 1 5 12V GND 2 6 12V GND 3 7 12V GND 4 8 12V D4P_PW1 4 pin Power Connector Signal Pin Pin Signal 12V 1 2 GND GND 3 4 5V ...

Page 83: ...tion describes the BIOS setup program The setup program lets you modify basic configuration settings The settings are then stored in a dedicated battery backed memory called NVRAM that retains the information even when the power is turned off To start the BIOS setup utility 1 Turn on or reboot your system 2 Press F2 or Del during POST Tab on remote console to start the BIOS setup utility 5 1 1 Set...

Page 84: ...seemingly small change to the Chipset setup options may cause the system to become unstable or unusable 6 1 4 Setup Variations Not all systems have the same BIOS setup layout or options While the basic look and function of the BIOS setup remains more or less the same for most systems the appearance of your Setup screen may differ from the charts shown in this section Each system design and chipset...

Page 85: ... for options that can directly be changed within the Main Setup screen BIOS Information It displays BIOS related information Platform Information It displays Platform information Memory Information This displays the total memory size System Language Choose the system default language System Date Adjust the system date MM Months DD Days YYYY Years ...

Page 86: ...http www tyan com 86 System Time Adjust the system clock HH 24 hours format MM Minutes SS Seconds ...

Page 87: ...iSCSI parameters Intel Virtual RAID on CPU This format allows the user to manage Intel Virtual RAID on CPU Trusted Computing Trusted Computing Setting ACPI Settings System ACPI Parameters Hardware Health Configuration Hardware health Configuration Onboard Device Configuration Onboard Device and Function Configuration AST2500 Super IO Configuration ...

Page 88: ...n Serial Port Console Redirection Option ROM Dispatch Policy Option ROM Dispatch Policy PCI Subsystem Settings PCI PCI X and PCI Express Settings Network Stack Configuration Network Stack Settings CSM Configuration CSM Configuration Enable Disable Option ROM execution setting etc USB Configuration USB Configuration Parameters ...

Page 89: ...http www tyan com 89 6 3 1 iSCSI Configuration submenu iSCSI Initiator Name The worldwide unique name of iSCSI Initiator Only IQM format is accepted Range is from 4 to 223 ...

Page 90: ...http www tyan com 90 6 3 2 Intel R VirtuaI RAID on CPU submenu ...

Page 91: ...ted Computing Security Device Support Enable or disable BIOS support for security device O S will not show Security device O S will not show Security Device TCG EFI protocol and INT1A interface will not be available Enabled Disabled ...

Page 92: ...ACPI Auto Configuration Enable or disable BIOS ACPI Auto Configuration Disabled Enabled Enable Hibernation Enables or disables System ability to Hibernate OS S4 Sleep State This option may not be effective with some operating systems Disabled Enabled ...

Page 93: ...http www tyan com 93 6 3 5 Hardware Health Configuration Auto Fan Control Auto Fan Control help Disabled Enabled BMC Alert Beep Enable Disable BMC Alert Beep On Off ...

Page 94: ...m 94 6 3 5 1 Sensor Data Register Monitoring When you enter the Sensor Data Register Monitoring submenu you will see the following dialog window pop out Please wait 8 10 seconds NOTE 1 SDR can not be modified Read only ...

Page 95: ...http www tyan com 95 ...

Page 96: ...www tyan com 96 6 3 6 Onboard Device Configuration Onboard LAN Intel X550 LAN Enable Disable Control function Enabled Disabled Chassis Intrusion Detention LAN Enable Disable control function Disabled Enabled ...

Page 97: ...http www tyan com 97 6 3 7 AST2500 Super IO Configuration ...

Page 98: ...ort Enable or Disable Serial Port COM Enabled Disabled Change Settings Select an optimal setting for Super IO Device Auto IO 3F8h IRQ 4 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 ...

Page 99: ...ort Enable or Disable Serial Port COM Enabled Disabled Change Settings Select an optimal setting for Super IO Device Auto IO 2F8h IRQ 3 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 ...

Page 100: ...ettings Wake system from S5 Enable or disable system wake on alarm event Select Fixed time system will wake on the hr min sec specified Select dynamic time system will wake on the current time increase minute s Disabled Fixed time Dynamic time ...

Page 101: ...Console Redirection Console redirection enable or disable Disabled Enabled Console Redirection Settings The settings specify how the host computer which the user is using will exchange data Both computers should have the same or compatible settings NOTE Console Redirection Settings menu only appear when Console Redirection was set to Enabled Legacy Console Redirection Legacy Console Redirection Se...

Page 102: ...al port transmission speed The speed must be matched on the other side Long or noisy lines may require lower speeds 38400 9600 19200 115200 57600 Data Bits 8 7 Parity A parity bit can be sent with the data bits to detect some transmission errors Even parity bit is 0 if the num of 1 s in the data bits is even Odd parity bit is 0 if the num of 1 s in the data bits is odd Mark parity bit is always 1 ...

Page 103: ...ne Hardware RTS CTS VT UTF8 Combo Key Support Enable VT UTF8 Combination Key Support for ANSI VT100 terminals Enabled Disabled Recorder Mode With this mode enabled only text will be sent This is to capture Terminal data Disabled Enabled Resolution 100x31 Enable or disable extended terminal resolution Disabled Enabled Legacy OS Redirection Resolution On Legacy OS the number of rows and columns supp...

Page 104: ...al port transmission speed The speed must be matched on the other side Long or noisy lines may require lower speeds 38400 9600 19200 115200 57600 Data Bits 8 7 Parity A parity bit can be sent with the data bits to detect some transmission errors Even parity bit is 0 if the num of 1 s in the data bits is even Odd parity bit is 0 if the num of 1 s in the data bits is odd Mark parity bit is always 1 ...

Page 105: ...ne Hardware RTS CTS VT UTF8 Combo Key Support Enable VT UTF8 Combination Key Support for ANSI VT100 terminals Enabled Disabled Recorder Mode With this mode enabled only text will be sent This is to capture Terminal data Disabled Enabled Resolution 100x31 Enable or disable extended terminal resolution Disabled Enabled Legacy OS Redirection Resolution On Legacy OS the number of rows and columns supp...

Page 106: ...http www tyan com 106 6 3 9 3 Legacy Serial Redirection Settings Legacy Serial Redirection Port Select a COM port to display redirection of Legacy OS and Legacy OPROM Messages COM1 COM2 ...

Page 107: ...er OS through a serial port COM1 COM2 Terminal Type VT UTF8 is the preferred terminal type for out of band management The next best choice is VT100 and then VT100 See above in Console Redirection Settings page for more Help with Terminal Type Emulation VT UTF8 VT100 VT100 ANSI Bits per Second Select serial port transmission speed The speed must be matched on the other side Long or noisy lines may ...

Page 108: ...tart the flow Hardware flow control uses two wires to send start stop signal None Hardware RTS CTS Data Bits Parity Stop Bits Read only 6 3 10 Option ROM Dispatch Policy Configuration Restore if Failure If system fails to boot and this option is set to Enabled software will reset settings of this page as well as CSM page to its default values automatically Disabled Enabled Onboard LAN1 X550 Enable...

Page 109: ...e option ROM execution for selected Slot Enabled Disabled PCIE_2 Empty Enable or Disable option ROM execution for selected Slot Enabled Disabled PCIE_3 Empty Enable or Disable option ROM execution for selected Slot Enabled Disabled PCIE_4 Empty Enable or Disable option ROM execution for selected Slot Enabled Disabled PCIE_5 Display Controller Device on Slot does not have an option ROM Enabled Disa...

Page 110: ...evices to be decoded in Above 4G Address Space Only if System supports 64 bit PCI decoding Enabled Disabled SR IOV Supporting If system has SR IOV capable PCIe devices this option Enable or Disable Single root IO virtualization Support Enabled Disabled 6 3 12 Network Stack Configuration Subsystem ...

Page 111: ...http www tyan com 111 Network Stack Enable Disable UEFI Network Stack Disabled Enabled ...

Page 112: ...y UEFI ROMs priority UEFI and Legacy Legacy only UEFI only Network Controls the execution of UEFI and legacy PXE OpROM Do not launch UEFI legacy Storage Controls the execution of UEFI and legacy PXE OpROM Do not launch UEFI legacy Video Controls the execution of UEFI and legacy PXE OpROM Do not launch UEFI legacy Other PCI devices Determines OpRom execution policy for devices other than network st...

Page 113: ...abled Disabled Auto XHCI Hand off This is a workaround for OSes without XHCI hand off support The XHCI ownership change should be claimed by XHCI driver Enabled Disabled USB Mass Storage Driver Support Enable Disable USB Mass Storage Driver Support Enabled Disabled Port 60 64 Emulation Enables I O port 60h 64h emulation support This should be enabled for the complete USB keyboard legacy support fo...

Page 114: ...evice reset time out USB mass storage device Start Unit command time out 20 sec 10 sec 30 sec 40 sec Device power up delay Maximum time the device will take before it properly reports itself to the Host Controller AUTO uses default value for a Root port it is 100 ms for a Hub port the delay is taken from Hub descriptor Auto Manual ...

Page 115: ...yan com 115 6 4 Platform Configuration Menu PCH Configuration Displays and provides option to change the PCH Settings Miscellaneous Configuration Server ME Configuration Configure Server ME Technology Parameters ...

Page 116: ...ation settings PCH SATA Configuration SATA devices and settings PCH sSATA Configuration sSATA devices and settings USB Configuration USB Configuration Settings PCH DFX Configuration PCH DFX Configuration Options PCH state after G3 Select S0 S5 for ACPI state after a G3 S0 S5 Leave power state ...

Page 117: ... Express Root Port Enabled Disabled PCIE ASPM PCI Express Root port ASPM Setting Disable ASPM ASPM L1 ASPM Auto L1 Substates PCI Express L1 Substates settings Disabled L1 1 L1 2 L1 1 L1 2 PCIe Speed Configure PCIe Speed Auto Gen1 Gen2 Gen3 Max Payload Size PCIE Max Payload Size Selection MPL 128B MPL 256B ...

Page 118: ...http www tyan com 118 6 4 1 2 PCH SATA Configuration ...

Page 119: ...A as Indentify the SATA port is connected to Solid State Drive or Hard Disk Drive IDE AHCI RAID SATA Port 0 1 2 3 4 5 6 7 Port 0 1 2 3 4 5 6 7 Disabled Enabled Hot Plug Enable Disable SATA Ports Hot Plug Support Disabled Enabled Configure as eSATA Configures port as External SATA eSATA Disabled Enabled ...

Page 120: ...anical Presence Switch Note Requires hardware support Disabled Enabled Spin Up Device AHCI Supports Staggered Spin up Disabled Enabled SATA Device Type Indentify the SATA port is connected to Solid State Drive or Hard Disk Drive Hard Disk Drive Solid State Drive 6 4 1 3 PCH sSATA Configuration ...

Page 121: ...ndentify the SATA port is connected to Solid State Drive or Hard Disk Drive IDE AHCI RAID Support Aggressive Link Power Mana Enable or Disable Aggressive Link Power Mana Disabled Enabled sSATA Port 0 1 2 3 4 5 Port 0 1 2 3 4 5 Disabled Enabled Hot Plug Enable Disable SATA Ports Hot Plug Support Disabled Enabled ...

Page 122: ...nabled sSATA Device Type Indentify the SATA port is connected to Solid State Drive or Hard Disk Drive Hard Disk Drive Solid State Drive SATA Topology Indentify the Secondary SATA Topology if it is Default or ISATA or Flex or DirectConnect or M2 Unknown ISATA Direct Connect Flex M2 ...

Page 123: ...http www tyan com 123 6 4 1 4 USB Configuration xHCI Idle L1 Mode of operation of xHCI controller Enabled Disabled ...

Page 124: ... Disabled ADR GPIO Select between GPIO_B or GPIO_C GPIO B GPIO C Host Partition Reset ADR Enable Enable Disables ADR on Host Partition Reset Enabled Disabled Enable Disable ADR Timer Held off for DEBUG PURPOSES ONLY Enabled Held off ADR timer expire time Select proper ADR timer value 25uS 50uS 100uS or 0 25uS 50uS 100uS 0uS ...

Page 125: ...DR timer multiplier Select proper ADR timer multiplier X1 8 24 40 56 64 72 80 88 96 X1 x8 x24 x40 x56 x64 x72 x80 x88 x96 6 4 2 Miscellaneous Configuration Active Video Select active video type Auto Onboard Device PCIE Device ...

Page 126: ...http www tyan com 126 6 4 3 General ME Configuration ...

Page 127: ... provides option to change the Common RefCode Settings UPI Configurtion Displays and provides option to change the UPI Settings Memory Configuration Displays and provides option to change the Memory Settings IIO Configuration Displays and provides option to change the IIO Settings Advance Power Management Configuration Displays and provides option to change the IIO Settings ...

Page 128: ...http www tyan com 128 6 5 1 Processor Configuration ...

Page 129: ...ces the XD feature flag to always return 0 Disable Enable Enable Intel R TXT Enables Intel R TXT Disable Enable VMX Enables the Vanderpool Technology takes effect after reboot Disabled Enabled Enable SMX Enables Safer Mode Extensions Disabled Enabled Lock Chipset Lock or Unlock chipset Disabled Enabled Hardware prefetcher MLC Streamer Prefetcher MSR 1A4h Bit 0 Disabled Enabled Adjacent Cache Prefe...

Page 130: ... 256M 512M 1G 2G MMIOH High Base Select MMIO High Base 56T 40T 24T 16T 4T 3T 2T 1T MMIO High Granularity Size Selects the allocation size used to assign mmioh resources Total mmioh space can be up to 32x granularity Per stack mmioh resource assignments are multiples of the granularity where 1 unit Per stack is the default allocation 1G 4G 16G 64G 256G 1024G ...

Page 131: ...Disabled 6 5 3 UPI General Configuration Submenu UPI Status UPI Status Help Link Speed Mode Select the UPI link speed as either the POR speed Fast or default speed Slow Slow Fast Link Frequency Select Allows for selecting the UPI Link frequency 9 6GB s 10 4GB s Auto Use Per Link Setting ...

Page 132: ...e Set the c_L0p_en Disable Reset it Auto Auto decides based on Si Compatibility Disable Enable Auto Link L1 Enable Enable Set the c_L1_en Disable Reset it Auto Auto decides based on Si Compatibility Disable Enable Auto 6 5 3 1 UPI Status Submenu ...

Page 133: ...Disables this feature Auto Sets it to the MRC default setting current default is Enable Auto POR Disabled Memory Frequency Enables Disables Automatic restoring of NVDIMMs Auto 1866 2133 2400 2666 Memory Topology Maximum Memory Frequency Selections in Mhz Do not select Reserved Memory RAS Configuration Displays and provides option to change the Memory Ras Settings ...

Page 134: ...http www tyan com 134 6 5 4 1 Memory Topology Submenu ...

Page 135: ... will disable XPT Prefetch Disable Enabled Mirror TAD0 Enable Mirror on entire memory for TAD0 Disable Enabled Enable Partial Mirror Partial mirror mode will enable the required size of memory to be mirrored If rank sparing is enabled partial mirroring will not take effect Mirror Enable will disable XPT Prefetch Disable Enabled Memory Rank Sparing Enable Disable Memory Rank Sparing Disable Enabled...

Page 136: ...shold Enable Disable Memory Rank Sparing SDDC Plus One Selects the address mode between System Physical Address or Reverse Address Disable Enabled ADDDC Sparing Enable Disable ADDDC Sparing Patrol Scrub Enable Disable Patrol Scrub Disable Enabled ...

Page 137: ...VT d Configuration menu Intel VMD technology Press Enter to bring up the Intel VT for Directed I O VT d Configuration menu PCIe Hot Plug Enable Disable PCIe ACPI Hot Plug globally Configuration menu Disabled Enabled Auto Manual PCIe ACPI Hot Plug Enable Disable PCIe ACPI Hot Plug globally or allow per port control When Disabled MSI is generated on HP event When Enabled _HPGPE message is generated ...

Page 138: ...t Disabled Enabled 6 5 6 Advanced Power Management Configuration CPU P State Control P State Control Configuration Sub Menu include Turbo XE and etc Hardware PM State Control Hardware P State setting CPU C State Control CPU C State setting Package C State Control Package C State setting CPU T State Control CPU T State setting ...

Page 139: ...nce state that the BIOS will set before OS hand off Max Performance Max Efficient Set by Intel Node Energy Efficient Turbo Energy Efficient Turbo Disable MSR 0x1FC 19 Disabled Enabled Turbo Mode Enable Disable processor Turbo Mode requires EMTTM enabled too Disabled Enabled CPU Flex Ratio Override Enable Disable CPU Flex Ratio Programming Disabled Enabled ...

Page 140: ...s Disable Hardware choose a P state based on OS Request Legacy P States Native Mode Hardware choose a P state based on OS guidance Out of Band Mode Hardware autonomously choose a P state No OS guidance Disable Native Mode Out of Band Mode Native Mode with No Legacy Support ...

Page 141: ... Enable Disable CPU C6 ACPI C3 report to OS Enabled Disabled Auto Enhanced Halt State Enables the Enhanced C1E state of the CPU takes effect after reboot Enabled Disabled OS ACPI Cx Enables the Enhanced C1E state of the CPU takes effect after reboot ACPI C2 ACPI C3 ...

Page 142: ...http www tyan com 142 6 5 6 4 Package C State Control Submenu Package C State Package C State Limit C0 C1 state C2 state C6 non Retention state C6 Retention state NO limit Auto ...

Page 143: ...http www tyan com 143 6 5 6 5 CPU T State Submenu CPU T State Control CPU T State setting Software Controller T States Enable Disable Software Controller T States Disabled Enabled ...

Page 144: ...imer Expiration value 3 minutes 4 minutes 5 minutes 6 minutes FBR 2 Timer Policy Configure how the system should respond if the FRB 2 Timer expires Not available if FRB 2 Timer is disabled Do Nothing Reset Power Down Power Cycle OS Watchdog Timer If enabled starts a BIOS timer which can only be shut off by management Software after the OS loads Helps determine that the OS successfully loaded or fo...

Page 145: ...isabled 5 minutes 10 minutes 15 minutes 20 minutes OS Wtd Timer Policy Configure how the system should respond if the OS Boot Watchdog Timer expires Not available if OS Boot Watchdog Timer is disabled Do Nothing Reset Power Down Power Cycle BMC Logos Enable or disable BMC logo Disabled Enabled System Event Log Press Enter to change the SEL event log configuration BMC network configuration Configur...

Page 146: ...ot Disabled Enabled Erase SEL Choose options for erasing SEL No Yes on next reset No on every reset When SEL is Full Choose options for reactions to a full SEL Do Nothing Erase Immediately Log EFI Status Codes Disable the logging of EFI Status Codes or log only error code or only progress code or both Both Disabled Error Code Progress Code ...

Page 147: ...http www tyan com 147 6 6 2 BMC Network Configuration ...

Page 148: ...se Unspecified Static DynamicBmcDhcp DynamicBmcNonDhcp IPV6 Support Enable or Disable LAN1 IPV6 Support Enabled Disabled Configuration Address Source Select the configure LAN channel parameters statically or dynamically by BIOS or BMC Unspecified option will not modify any BMC network parameters during BIOS phase Unspecified Static DynamicBmcDhcp Server Management Port2 IPV6 Support Enable or Disa...

Page 149: ... Password Description Read only Administrator Password Install or change the password User Password Install or change the password Security Frozen Mode Enable or disable HDD security freeze lock Disable to support secure erase function ...

Page 150: ...hen Platform Key PK is enrolled system mode if 1 system running in User mode with enrolled platform Key PK 2 CSM function is disabled Disabled Enabled Secure Boot Mode Secure Boot mode selector Standard Custom In Custom mode Secure Boot Variables can be configured without authentication Custom Standard ...

Page 151: ...sion Factory Defaults is set to Enabled Install Factory Default Keys Force System to User Mode install all Factory Default Keys Enroll Efi Image Allow the image to run in Secure Boot mode Enroll SHA256 hash of the binary into Autorized Signature Database db Save all Secure Boot variables Save NVRAM content of Secure Boot policy variables to the files EFI_SIGNATURE_LIST data format in root folder o...

Page 152: ...256 384 512 2 Autheticated UEFI Variable 3 EFI PE COFF Image SHA256 Key Source Default External Mixed Test Save to File Set New Append Erase Authorized Signatures Enroll Factory Defaults or load certificates from a file 1 Public Key Certificate in a EFI_signature_LIST b EFI_CERT_X509 DER encoded c EFI_CERT_RSA2048 bin d EFI_CERT_SHA256 384 512 2 Autheticated UEFI Variable 3 EFI PE COFF Image SHA25...

Page 153: ..._RSA2048 bin d EFI_CERT_SHA256 384 512 2 Autheticated UEFI Variable 3 EFI PE COFF Image SHA256 Key Source Default External Mixed Test Set New Append OsRecovery Signatures Enroll Factory Defaults or load certificates from a file 1 Public Key Certificate in a EFI_signature_LIST b EFI_CERT_X509 DER encoded c EFI_CERT_RSA2048 bin d EFI_CERT_SHA256 384 512 2 Autheticated UEFI Variable 3 EFI PE COFF Ima...

Page 154: ...Boot option Disabled Enabled Wait For ESC If Error Enable or disable wait ESC key Function When chassis intrusion CMOS clear or BMC not Response Disabled Enabled Endless Boot Enable or disable Endless Boot Disabled Enabled Boot Option 1 Select the first boot device IBA XE Slot v2372 UEFI Built in EFI Shell Disabled Boot Option 2 ...

Page 155: ...t boot device IBA XE Slot v2372 UEFI Built in EFI Shell Disabled 6 8 1 Network Device BBS Priorities Configuration Boot Option 1 Sets the system boot order Device Name Disabled Boot Option 2 Sets the system boot order Device Name Disabled ...

Page 156: ...g any changes Save Changes and Reset Reset the system after saving the changes Discard Changes and Reset Reset system setup without saving any changes Save Changes Save changes done so far to any of the setup options Discard Changes Discard changes done so far to any of the setup options Restore Defaults Restore Load Default values for all the setup options ...

Page 157: ...http www tyan com 157 Save as User Defaults Save the changes done so far as User Defaults Restore User Defaults Restore the User Defaults to all the setup options ...

Page 158: ...http www tyan com 158 NOTE ...

Page 159: ... 7 1 Flash Utility Every BIOS file is unique for the motherboard it was designed for For Flash Utilities BIOS downloads and information on how to properly use the Flash Utility with your motherboard please check the TYAN web site at http www tyan com NOTE Please be aware that by flashing your BIOS you agree that in the event of a BIOS flash failure you must contact your dealer for a replacement BI...

Page 160: ... errors 0x60 0x8F DXE execution up to BDS 0x90 0xCF BDS execution 0xD0 0xDF DXE errors 0xE0 0xE8 S3 Resume PEI 0xE9 0xEF S3 Resume errors PEI 0xF0 0xF8 Recovery PEI 0xF9 0xFF Recovery errors PEI Standard Checkpoints SEC Phase Status Code Description 0x00 Note used Progress Codes 0x01 Power on Reset type detection soft hard 0x02 AP initialization before microcode loading 0x03 North Bridge initializ...

Page 161: ...ridge initialization after microcode loading 0x0A OEM initialization after microcode loading 0x0B Cache initialization SEC Phase None PEI Phase SEC Error Codes 0x0C 0x0D Reserved for future AMI SEC error codes 0x0E Microcode not found 0x0F Microcode not found ...

Page 162: ...ization is started 0x1A Pre Memory South Bridge initialization South Bridge module specific 0x1B Pre memory South Bridge initialization South Bridge module specific 0x1C Pre Memory South Bridge initialization South Bridge module specific 0x1D 0x2A OEM pre memory initialization codes 0x2B Memory initialization Serial Presence Detect SPD data reading 0x2C Memory initialization Memory presence detect...

Page 163: ...odule specific 0x3D Post Memory South Bridge initialization South Bridge module specific 0x3E Post Memory South Bridge initialization South Bridge module specific 0x3F 0x4E OEM post memory initialization codes 0x4F DXE PIL is started PCI Error Codes 0x50 Memory initialization error Invalid memory type or incompatible memory speed 0x51 Memory initialization error SPD reading has failed 0x52 Memory ...

Page 164: ...xEA S3 Resume Boot Script error 0xEB S3 OS wake error 0xEC 0xEF Reserved for future AMI error codes Recovery Progress Codes 0xF0 Recovery condition triggered by firmware Auto recovery 0xF1 Recovery condition triggered by user forced recovery 0xF2 Recovery process started 0xF3 Recovery firmware image is found 0xF4 Recovery firmware image is loaded 0xF5 0xF7 Reserved for future AMI progress codes Re...

Page 165: ...ecific 0x65 CPU DXE initialization CPU module specific 0x66 CPU DXE initialization CPU module specific 0x67 CPU DXE initialization CPU module specific 0x68 PCI host bridge initialization 0x69 North Bridge DXE initialization is started 0x6A North Bridge DXE SMM initialization is started 0x6B North Bridge DXE initialization North Bridge module specific 0x6C North Bridge DXE initialization North Brid...

Page 166: ...x7A 0x7F Reserved for future AMI DXE codes 0x80 0x8F OEM DXE initialization codes 0x90 Boot Device Selection BDS phase is started 0x91 Driver connecting is started 0x92 PCI Bus initialization is started 0x93 PCI Bus Hot Plug Controller initialization 0x94 PCI Bus Enumeration 0x95 PCI BUS Request Resources 0x96 PCI Bus Assign Resources 0x97 Console output devices connect 0x98 Console Input devices ...

Page 167: ...Virtual Address MAP End 0xB2 Legacy Option ROM initialization 0xB3 System Reset 0xB4 USB hot plug 0xB5 PCI bus hot plug 0xB6 Clean up of NVRAM 0xB7 Configuration Reset reset of NVRAM settings 0xB8 0xBF Reserved for future AMI codes 0xC0 0xCF OEM BDS initialization codes DXE Error Codes 0xD0 CPU initialization error 0xD1 North Bridge initialization error 0xD2 South Bridge initialization error 0xD3 ...

Page 168: ...ol is not available 8 Platform PCI resource requirements cannot be met ACPI ASL Checkpoints Status Code Description 0x01 System is entering S1 sleep state 0x02 System is entering S2 sleep state 0x03 System is entering S3 sleep state 0x04 System is entering S4 sleep state 0x05 System is entering S5 sleep state 0x10 System is waking up from the S1 sleep state 0x20 System is waking up from the S2 sle...

Page 169: ...http www tyan com 169 NOTE ...

Page 170: ...Ctrl Cable M1715T71 FPB board to S7102 M1715T71 FPB Connect to S7102 M B J1 FPIO_1 3 USB Cable USB cable to S7102 USB cable Connect to S7102 M B USB cable USB3_FPIO1 4 HDD PWR Cable M1271T71 BP12 to S7102 M B M1271T71 BP12 Connect to S7102 M B PW5 HDD_PW1 5 Mini SAS HD Cable M1271T71 BP12 to S7102 M B M1271T71 BP12 Connect to S7102 M B Mini_SAS0 PCH_SSATA_0123 Mini_SAS1 PCH_SATA_0123 Mini_SAS2 PCH...

Page 171: ...http www tyan com 171 6 GPU PWR Cable S7102 to GPU Card S7102 Connect to GPU Card PE_PW1 GPU1 PE_PW4 GPU2 ...

Page 172: ...300MM GPU PWR CABLE 2 4P M P4 2 GPU 2 3P M P4 2 GPU 2 4P M P4 2 FT76 B7922 FRU CS 0460 332810000515 TF POWER CORD SBU EU 250 V 16 AWG 1 0mm 1800mm AC PWR CORD FRU CS 0330 332810000514 TF POWER CORD SBU US 125 V 16 AWG 1 31mm 1800mm AC PWR CORD Power Supply FRU PS 0090 471100000238 TF POWER SUPPLY SBU 1200 W DELTA DPS 1200AB 4 B 00F 1U MODULE REV 00F FAN FRU TH 0210 336210000056 TF FAN SBU FAN 12V ...

Page 173: ...http www tyan com 173 NOTE ...

Page 174: ...mp Sensors This section aims to help readers identify the locations of some specific FAN and Temp Sensors on the motherboard A table of BIOS Temp sensor name explanation is also included for readers reference NOTE The red dot indicates the sensor ...

Page 175: ...Sensor SYS_FAN_1 12 They detect the fan speed rpm 2 Temp Sensor SYS_Air_Inlet and M B_Air_Inlet They detect the system temperature around NOTE The CPU PECI is measured in a scale defined by Intel not in Fahrenheit or Celsius BIOS Temp Sensor Name Explanation ...

Page 176: ...http www tyan com 176 ...

Page 177: ...DIM_CH_A The highest temperature of CPU0 DIMM channel A slot P0_MC0_DIM_CH_B The highest temperature of CPU0 DIMM channel B slot P0_MC0_DIM_CH_C The highest temperature of CPU0 DIMM channel C slot P0_MC1_DIM_CH_D The highest temperature of CPU0 DIMM channel D slot P0_MC1_DIM_CH_E The highest temperature of CPU0 DIMM channel E slot P0_MC1_DIM_CH_F The highest temperature of CPU0 DIMM channel F slot...

Page 178: ...N_5 Fan speed of SYS_FAN_5 SYS_FAN_6 Fan speed of SYS_FAN_6 SYS_FAN_7 Fan speed of SYS_FAN_7 SYS_FAN_8 Fan speed of SYS_FAN_8 SYS_FAN_9 Fan speed of SYS_FAN_9 SYS_FAN_10 Fan speed of SYS_FAN_10 SYS_FAN_11 Fan speed of SYS_FAN_11 SYS_FAN_12 Fan speed of SYS_FAN_12 ...

Page 179: ...r expectations TYAN s website http www tyan com provides easy to access resources such as in depth Linux Online Support sections with downloadable Linux drivers and comprehensive compatibility reports for chassis memory and much more With all these convenient resources just a few keystrokes away users can easily find their latest software and operating system components to keep their systems runni...

Page 180: ...proper maintenance of products NOTE A receipt or copy of your invoice marked with the date of purchase is required before any warranty service can be rendered You may obtain service by calling the manufacturer for a Return Merchandise Authorization RMA number The RMA number should be prominently displayed on the outside of the shipping carton and the package should be mailed prepaid TYAN will pay ...

Reviews: