182
Appendix IV: FRU Parts Table
TN73-B8037 FRU Parts
Item
Model Number
Part Number
Picture
Description
Node
FRU-SO-9480
451T62000002
2.5" node KIT, TN73-B8037, Left node
FRU-SO-9470
451T62000001
2.5" node KIT, TN73-B8037, Right Node
FAN
Module
FRU-TS-9250
336210000073
System FAN FRU for TN73-B8037;
3*40*40*56mm w/ fan cage; RoHS
(336210000073 )
Power
FRU-PS-9350
471100000319
TF-POWER SUPPLY;SBU,2000
W,DELTA,DPS-2000CB C,(S0F),1U
MODULE,REV.S0F
HDD
backplane
FRU-BP-9330
411T62000064
M1311T73-BP12E-4,R02
PCBA
FRU-RC-1170
411T62000023
TF-PWA;SBU,TN73-B8037,M8037T73-L16-1L,
R01,TYAN,FOR BB
FRU-RC-1180
411T62000027
TF-PWA;SBU,TN73-B8037,M8037T73-R16-1L
,R01,TYAN,FOR BB
Heatsink
FRU-TH-0260
343T58100002
HF-HEATSINK;SBU,AL/CU,SOLPI
PE,SP3-1U-PASSIVE HEATSINK,
1A0-F083300960,119X78.6X24.8MM,SCREW,
GA88-B8021
Air duct
FRU-TA-0220
344T62000001
Air duct
Rack
Mounting
Parts
FRU-AS-0200
452T62000002
TF-SLIDE RAIL KIT;SBU,SGCC+
STEEL+SCREW,TOOL-LESS, WITH
LOCKIN,A5612650,KINGSLIDE,TN73-B8037
Cable
FRU-CS-1440
422T62000007
TF-AC/DC POWER CABLE;SBU,18 AWG,60
mm, PWR CABLE,2*12P(M),P4.2
/2*12P(M),P4.2,TN73-B8037
FRU-CS-1450
422T62000003
TF-AC/DC POWER CABLE;SBU,20 AWG,460
mm, Micro Fit 2*12P CABLE, Micro Fit
2*12P(M),P3.0/Micro Fit
2*12P(M),P3.0,TN73-B8037
FRU-CS-1460
422T62000001
TF-AC/DC POWER CABLE;SBU,20 AWG,400
mm,Micro Fit 2*6P CABLE, Micro Fit
2*6P(M),P3.0/Micro Fit
2*6P(M),P3.0,TN73-B8037
FRU-CS-1470
422T62000009
TF-CABLE ASSY;SAS INTERNAL,SBU,32
AWG,160 mm,SlimSAS 8i LE to SlimSAS 8i
CABLE,SlimSAS 8i 74P LE/SlimSAS 8i
74P,TN73-B8037
FRU-CS-1480
422T62000010
TF-CABLE ASSY;SAS INTERNAL,SBU,32
AWG,220 mm,SlimSAS 8i RE to SlimSAS 8i
CABLE,SlimSAS 8i 74P RE/SlimSAS 8i
74P,TN73-B8037
FRU-CS-1490
422T62000011
TF-CABLE ASSY;SAS INTERNAL,SBU,32
AWG,400 mm,SlimSAS 4i LE to SlimSAS 4i
CABLE,SlimSAS 4i 74P LE/SlimSAS 4i
74P,TN73-B8037
FRU-CS-1500
422T62000012
TF-CABLE ASSY;USB EXTERNAL,SBU,32
AWG,100 mm, EXTERNAL USB CABLE,USB
TYPE C(M)/STD USB 3.0(F),TN73-B8037
FRU-CS-0330
332810000517
A/C Power Cord, L=1800mm, US type
Summary of Contents for TN73-B8037
Page 1: ...TN73 B8037 Service Engineer s Manual...
Page 14: ...14 http www tyan com NOTE...
Page 29: ...29 http www tyan com 1 5 4 Chassis Dimensions...
Page 50: ...50 http www tyan com NOTE...
Page 80: ...80 http www tyan com NOTE...
Page 83: ...83 http www tyan com 5 2 Block Diagram S8037 Block Diagram...
Page 84: ...84 http www tyan com 5 3 Motherboard Mechanical Drawing...
Page 92: ...92 http www tyan com...
Page 101: ...http www tyan com 101 6 3 1 1 Node 0 Information Configuration...
Page 110: ...http www tyan com 110...
Page 126: ...http www tyan com 126 6 3 15 NVMe Configuration...
Page 127: ...http www tyan com 127 6 3 16 SATA Configuration...
Page 140: ...http www tyan com 140 6 4 1 2 Socket 0 Information...
Page 145: ...http www tyan com 145 6 5 3 DF Common Options Scrubber Memory Addressing ACPI...
Page 149: ...http www tyan com 149 6 5 3 4 UMC Common Options...
Page 150: ...http www tyan com 150 6 5 3 4 1 DDR4 Common Options...
Page 162: ...http www tyan com 162 6 5 5 2 BMC Network Configuration...
Page 165: ...http www tyan com 165 6 5 5 2 1 Add User Settings User Name Enter BMC User Name...
Page 166: ...http www tyan com 166 6 5 5 2 2 Delete User Settings User Name Enter BMC User Name...
Page 167: ...http www tyan com 167 6 5 5 2 3 Change User Settings...
Page 179: ...http www tyan com 179 BIOS Temp Sensor Name Explanation...
Page 181: ...http www tyan com 181 SYS_FAN_5 Fan speed of SYS_FAN_5 SYS_FAN_6 Fan speed of SYS_FAN_6...