background image

                                                       

http://www.tyan.com

 

49

3.2.5      Replacing the Power Distribution Board 

 
Follow these instructions to replace the Power Distribution Board. 
 
1. 

Disconnect the cables on the power distribution board. 

 

2. 

Unscrew to lift up the power distribution board. 

 

   

3. 

Follow the steps described earlier in reverse order to reinstall the power 
distribution board into the chassis. 

Summary of Contents for TN70J-E3250

Page 1: ...1 http www tyan com TN70J E3250 Service Engineer s Manual...

Page 2: ...2 http www tyan com...

Page 3: ...for accuracy and reliability prior to printing MiTAC assumes no liability whatsoever and disclaims any express or implied warranty relating to sale and or use of TYAN products including liability or...

Page 4: ...les These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate rad...

Page 5: ...hapter 2 Setting Up This chapter covers procedures on installing the hard drives and connecting the JBOD Expansion Chassis to HBA or RAID Subsystem and other optional parts Chapter 3 Replacing Compone...

Page 6: ...the purpose of this pin If your outlet does not support this kind of plug contact your electrician to replace your obsolete outlet Do not place anything on the power cord Place the power cord where it...

Page 7: ...l hazard The potential for injury exists if cautions are not observed Consult equipment documentation for specific details Caution Slide mounted equipment is not to be used as a shelf or a work space...

Page 8: ...ock or damage to your equipment Lift equipment using both hands and with your knees bent Equipment Racks To avoid injury or damage to the equipment Observe local occupational health and safety require...

Page 9: ...Model in a rack do not place equipment on top of the unit It will cause restricted airflow and might cause damage to the equipment Make sure the product is properly matted with the rails Products that...

Page 10: ...ning hazardous energy levels Do not exceed the level of repair specified in the procedures in the product documentation Improper repairs can create a safety hazard Allow the product to cool before rem...

Page 11: ...11 http www tyan com instructions...

Page 12: ...http www tyan com 12...

Page 13: ...ack 31 2 3 3 Rack mounting the Storage 32 2 4 Chassis Expansion 33 2 4 1 Single SAS in Out Port Configuration 33 2 4 2 Share Storage 2 SAS in Ports 35 2 4 3 Share Storage 3 SAS in Ports 35 2 4 4 IO Po...

Page 14: ...1 4 2 3 Smart Fan Speed Control 62 4 2 4 SES elements status 62 4 2 5 Front Panel Warning LED Indication 65 4 2 6 SAS Link LED behavior 65 4 3 Upgrade Expander Firmware 67 4 3 1 FW utility Xutils from...

Page 15: ...ness environment It provides a maximum data protection and exceptional performance in a storage subsystem Target usage ranges are set from small business to departmental and corporate server needs The...

Page 16: ...Range 100 127V AC 5 5A 200 240V AC 3A Frequency 50 60 Hz Output Watts 450 Watts Expander Controller board Expander Controller LSI SAS 3X24R Connector 3 mini SAS HD connectors Connector configuration 1...

Page 17: ...http www tyan com 17 RoHS RoHS 6 6 Compliant Yes Package Contains JBOD System TN70J E3250 JBOD System Manual 1 Web User s manual 1 Quick Installation Guide Installation CD 1 TYAN installation CD...

Page 18: ...System Front View HDD Sequence HDD2 HDD5 HDD8 HDD11 HDD1 HDD4 HDD7 HDD10 HDD0 HDD3 HDD6 HDD9 No Description 1 12 2 5 3 5 hot swap HDD trays 2 Power Button with LED 3 Over temperature voltage PSU Fan s...

Page 19: ...stem Off Off System works fine Power LED On Green System powered on Off Green System standing by Off Off System AC off HDD LED Definitions Drive State Activity LED Green color Status LED Orange color...

Page 20: ...ear View No Description 1 1 1 450W hot swap Power Supply Unit 2 SAS Port Link LED 3 SAS Port Speed LED 4 SAS IN Port 0 5 SAS OUT Port 1 E 6 SAS OUT Port 2 E NOTE Please contact with TYAN technical sup...

Page 21: ...ion 1 12 2 5 3 5 hot swap HDD trays 2 M1275T70B BP12 12 HDD Backplane Board 3 System Fans 4 M1601T70 D PDB Power Distribution Board 5 E3250 Expander Board 6 1 1 450W hot swap Power Supply Unit NOTE Th...

Page 22: ...http www tyan com 22 NOTE...

Page 23: ...0 2 Tools The following procedures require only a few tools including the following A cross head Phillips screwdriver A grounding strap or an anti static pad Most of the electrical and mechanical conn...

Page 24: ...onnectors and leads The expander board is pre installed in the system When removing the expander board always place it on a grounded anti static surface until you are ready to reinstall it Hold electr...

Page 25: ...bays 1 1 hot swap 450W redundant Power Supply 2 System Fans 1 M1701T70 FPB 1 M1601T70 D PDB 1 M1806G70 Fan Board 1 M1275T70B BP12 12 HDD BP 2 1 2 Accessories If any items are missing or appear damaged...

Page 26: ...2 Installing Hard Drives Follow these instructions to install 2 5 3 5 hard drives Warning Always install the hard disk drive to the chassis after the chassis is secured on the rack 1 Push the latch to...

Page 27: ...http www tyan com 27 2 Option 1 2 5 HDD Place a 2 5 hard drive into the HDD tray and secure the HDD with 4 HDD screws 3 Option 2 3 5 HDD Unscrew the HDD tray...

Page 28: ...http www tyan com 28 4 Place a 3 5 hard drive into the HDD tray Secure the HDD to the HDD tray with 5 screws 5 Reinsert the HDD tray into the chassis...

Page 29: ...kit Rack mounting kit Sliding Rails x 2 Mounting Ears x 2 2 3 1 Installing the inner Rails to the Chassis Follow these instructions to mount the TYAN TN70J E3250 into an industry standard 19 rack NOTE...

Page 30: ...http www tyan com 30 3 Pull the inner sliding rail forward to secure it to the chassis 4 Align the inner sliding rail on the other side of the chassis...

Page 31: ...http www tyan com 31 2 3 2 Installing the Outer Rails to the Rack 1 Secure the outer rails to the rack...

Page 32: ...tyan com 32 2 3 3 Rack mounting the Storage 1 Lift the unit and then insert the inner slide rails into the middle rails 2 Push the whole system into the rack 3 Secure the whole system to the rack with...

Page 33: ...share storage or other IN OUT port configurations 2 4 1 Single SAS in Out Port Configuration Connection diagram A Connect one end of the External Mini SAS HD cable to the SAS OUT port on the Server an...

Page 34: ...http www tyan com 34 Connection diagram volume expansion NOTE Maximum quantity of HDD that can be supported should be based on each type of HBA cards being used on server side...

Page 35: ...http www tyan com 35 2 4 2 Share Storage 2 SAS in Ports 2 4 3 Share Storage 3 SAS in Ports...

Page 36: ...http www tyan com 36 2 4 4 IO Port Connection...

Page 37: ...e power switch of RAID system NOTE RAID controller is required for RAID support This step is to ensure users to understand the sequence of turning off machines when a RAID system is involved in config...

Page 38: ...http www tyan com 38 NOTE...

Page 39: ...This section is for the reference of the trained service technicians End users are not recommended to replace or remove components 3 1 Removing the Cover Before replacing any parts you must remove th...

Page 40: ...http www tyan com 40 3 Unscrew the front top cover 4 Push the latches aside to loosen the top cover Remove the top cover from the chassis...

Page 41: ...ackplane Board 3 2 1 Replacing Expander Board Before replacing the expander board remove cables connected to the expander board Follow these instructions to remove all cables 1 Disconnect all cables 2...

Page 42: ...LSI SAS Expander 3x24R 3x36R EXT I O 2 Mini SAS HD IN 1 Mini SAS HD OUT Total support 10 Mini SAS HD Connector to HDD 1 E3250 1214E U8 3 Mini SAD HD connectors to 12 HDDs 2 E3250 2414E U8 6 Mini SAS H...

Page 43: ...r J68 SSI_FP Connector J22 SAS0_0_3 Connector J23 SAS0_4_7 Connector J24 SAS0_8_11 Connector J37 EXT_A_IN_Connector J38 EXT_B_OUT Connector J40 EXT_C_OUT Connector Jumper Definition J3 TX J4 RX Mode S...

Page 44: ...2 Replacing the Fans Follow these instructions to replace the fans 1 Press the latches to lift up the fan 2 Replace the failed fan module with a new one Follow the procedures described earlier in rev...

Page 45: ...the Fan Backplane Board Follow these instructions to replace the Fan Backplane Board in your system 1 Disconnect the cables attached to the Fan Backplane Board 2 Use a screw drive to unscrew the fan...

Page 46: ...http www tyan com 46 3 Release the 14 screws on the Fan Backplane Board to replace a new one 4 Follow the steps described in reverse order to reinstall the fan cage...

Page 47: ...ctor 254 mm x 82 mm 4 layer PCB Integrated I O 2 1x4pin R A Power Connector 8 2x2pin Fan Connectors 1 2 x10pin Barebone Fan Connector 1 2x2pin Connector for S7015 3 2 3 2 Fan BP Board LED Definitions...

Page 48: ...installed Power Supply Units Please unplug the power cord before you follow these instructions to replace the power supply units 1 Press the latch to pull the power supply out 2 After replacing a new...

Page 49: ...ese instructions to replace the Power Distribution Board 1 Disconnect the cables on the power distribution board 2 Unscrew to lift up the power distribution board 3 Follow the steps described earlier...

Page 50: ...ttp www tyan com 50 3 2 6 Replacing the HDD Backplane Board Follow these instructions to replace the HDD Backplane Board 1 Pull the power supply units out 2 Disconnect the cables 3 Unscrew the fan cag...

Page 51: ...http www tyan com 51 4 Lift up the fan cage 5 Unplug all cables connected to the HDD BP Board...

Page 52: ...http www tyan com 52 6 Unscrew the HDD BP Board 7 Release 7 push pins to lift the mylar 8 Reinstall the HDD BP Board into the chassis following the steps in reverse...

Page 53: ...Backplane Board in details Front view Rear view Form Factor W436 x L82 mm 8 layer PCB Specifications 12 port SAS 12G SATA 6G 3 Mini SAS SATA SAS Connectors 1 2x4 pin power Connector 1 4 pin power conn...

Page 54: ...54 3 2 6 2 Connector Pin Definitions PW1 8 pin Power Connector Pin 1 Pin 2 Pin 3 Pin 4 GND GND GND GND Pin 5 Pin 6 Pin 7 Pin 8 P12V P12V P12V P12V PW2 4 pin Power Connector Reserved Pin 1 2 3 4 Signal...

Page 55: ...om 55 3 2 7 Replacing the Front Panel Board Follow these instructions to replace the Front Panel Board 1 Pull all HDD trays out 2 Unscrew the front panel bracket 3 Push the front panel bracket forward...

Page 56: ...Unscrew to take out the front panel bezel 5 Unscrew the Front Panel Board FPB and disconnect the front panel cable to replace with a new FPB 4 Reinstall the Front Panel Board into the chassis followin...

Page 57: ...tor 18 5MMx44 2MM 4 Layer PCB Connectors One 2x15 pin header for front panel connector of motherboard and HDD backplane board LEDs Power On Off LED Color Green after power on ID LED Color Blue Warning...

Page 58: ...r Voltage PSU fail On Green No failure ID LED On Blue System identified Off Off System not identified J1 FPIO connector Definition Pin Pin Definition PW_LED 1 2 5VSB Key 3 4 ID_LED PW_LED 5 6 ID_LED H...

Page 59: ...BA card to work with TN70J E3250 In addition user is advised to install management tool which is released by HBA providers and install it on the operating system in order to access the element status...

Page 60: ...http www tyan com 60 For other configuration such as 3 SAS IN or 1 SAS OUT and 2 SAS IN or share storage configurations please contact Tyan technical support...

Page 61: ...an function to change the fan speed base on the enclosure temperature Firmware continues monitoring voltage values temperature values power supply status and cooling RPM values When one or more below...

Page 62: ...rotocol to set fan speed but the action isn t always success due to expander firmware would overwrite user s setting for the high temperature condition For example user may want to slow down fan speed...

Page 63: ...ame in the table Please use SES nickname page to query them Here is the mapping table for reference 1 Temperature table Item Name 1 System Air Inlet sensor 2 MB Air Inlet sensor 3 Expander die tempera...

Page 64: ...http www tyan com 64 And below figure shows where the elements are For array devices when the enclosure is linked with host and the array devices status will show up in Avago MSM utility...

Page 65: ...termine which elements status has changed to alerting condition Please refer to chapter 4 2 4 For warning in Voltage status and Temperature status please contact our technical support For warning in F...

Page 66: ...at certain level If the devices being used can support 12Gb s ex HBA and is operating in 12Gb s the Speed LED will show steady green If the devices being used can only support 3Gb s or 6Gb s or the de...

Page 67: ...AS domain and their SAS address C Xutils windows g3Xutil exe i get avail g3Xutil LSI SAS Expander Utility Version 6 0 0 0 Copyright c 2014 LSI Corporation All rights reserved Initializing Interface WA...

Page 68: ...own 2 Once SAS address is obtained please download new firmware to the target SAS address C Xutils windows g3Xutil exe i 500e0810000272bf down fw sas3xfw fw 1 g3Xutil LSI SAS Expander Utility Version...

Page 69: ...ge is successful Are you sure to download file to expander y n y Downloading File Download Complete Post validating Post Validation of image is successful Download Successful 4 After firmware and sett...

Page 70: ...http www tyan com 70 NOTE...

Page 71: ...450W PSU FAN CFAN 0330 336252012309 12000RPM 60 60 38MM 4PIN fan Rack Mounting Parts CRAL 0170 340786900010 Slide Rail Kit Cable FRU CS 0330 332810000514 AC Power Cord US type L 1800mm CCBL 0300 3328...

Page 72: ...http www tyan com 72 NOTE...

Page 73: ...to and from computer storage devices such as hard drives and tape drives SES SCSI Enclosure Services Most SCSI enclosure products support this protocol Enclosure products can be communicated by using...

Page 74: ...http www tyan com 74 NOTE...

Page 75: ...ervice beyond their expectations TYAN s website http www tyan com provides easy to access resources such as in depth Linux Online Support sections with downloadable Linux drivers and comprehensive com...

Page 76: ...oper maintenance of products NOTE A receipt or copy of your invoice marked with the date of purchase is required before any warranty service can be rendered You may obtain service by calling the manuf...

Reviews: