http://www.tyan.com
40
Intel®Xeon®processor E5-2600/4600 product families UDIMM Support
1.35V 1.50V
Ranks Per DIMM &
Data Width
Memory Capacity per DIMM
1DPC
2DPC
1DPC
2DPC
SRx8 Non-ECC
1 GB
2GB
4GB N/A N/A
1066,
1333
1066,
1333
DRx8 Non-ECC
2GB
4GB
8GB N/A N/A
1066,
1333
1066,
1333
SRx16 Non-ECC
512 MB
1GB
2GB N/A N/A
1066,
1333
1066,
1333
SRx8 ECC
1GB
2GB
4GB 1066
1066
1066,
1333
1066,
1333
DRx8 ECC
2GB
4GB
8GB 1066
1066
1066,
1333
1066,
1333
NOTE 1:
The blue blocks indicate that the DRAM Densities are supported but not validated.
NOTE 2:
The grey blocks indicate that the DRAM Densities are supported and validated.
NOTE 3:
1DPC => One dimm per channel
NOTE 4:
2DPC => Two dimm per channel
NOTE 5:
3DPC => Three dimm per channel
Supported DRAM Densities are 1Gb, 2Gb and 4Gb. Only 2Gb and 4Gb are validated
by Intel.
Command Address Timing is 1N for 1DPC and 2N for 2DPC.
Romley-EP/EX platform does not support 3DPC when using UDIMMs.
Intel®Xeon®processor E5-2600/4600 product families LRDIMM Support
1.35V 1.50V
Ranks Per DIMM &
Data Width
Memory Capacity per
DIMM
1&2DPC
3DPC
1&2DPC
3DPC
QRx4 (DDP)
16GB
32GB 1066
1066
1066,
1333
1066
QRx8 (P)
8GB
16GB 1066
1066
1066,
1333
1066
NOTE:
The grey blocks indicate that the DRAM Densities are supported and validated.
Physical Rank is used to calculate DIMM Capacity.
Supported and validated DRAM Densities are 2Gb and 4Gb.
Command Address Timing is 1N.
The speeds are estimated targets and will be verified through simulation.
For 3SPC/3DPC -Rank Multiplication (RM) >= 2.
DDP -Dual Die Package DRAM stacking. P –Planer monolithic DRAM Die.
Romley-EP/EX platform does not support 3DPC when using E5-2400 LRDIMMs.
Summary of Contents for S7052
Page 2: ...http www tyan com 2...
Page 14: ...http www tyan com 14 NOTE...
Page 17: ...http www tyan com 17 2 2 Block Diagram S7052 Block Diagram...
Page 20: ...http www tyan com 20 J3 J22 J77 J76 J75 J71 J42 J4 J6 J30...
Page 22: ...http www tyan com 22 J55 J63 J10 J34 J24 J25 J33...
Page 24: ...http www tyan com 24 J27 J57 J58 SATA0 1 SATA2 3 SATA4 5 LED1 J5...
Page 26: ...http www tyan com 26 J70 J78 J59 J79 J43...
Page 28: ...http www tyan com 28 J80 J54...
Page 55: ...http www tyan com 55 3 3 2 1 Socket 0 1 CPU Information Read only...
Page 59: ...http www tyan com 59 3 3 4 SAS Configuration Read only...
Page 64: ...http www tyan com 64...
Page 65: ...http www tyan com 65 3 3 8 Super IO Configuration Super IO Chip Read only...
Page 73: ...http www tyan com 73 3 4 1 North Bridge...
Page 80: ...http www tyan com 80 3 4 1 3 DIMM Information Submenu Read only...
Page 91: ...http www tyan com 91 3 8 Event Logs Read only...
Page 94: ...http www tyan com 94 NOTE...
Page 104: ...http www tyan com 104 BIOS Temp Sensor Name Explanation...
Page 106: ...http www tyan com 106 NOTE...