Feature
Option
Description
Configure Remote Access type and parameters
Enabled
Remote Access
Disabled
Enables remote access to system
through serial port.
NOTE:
The items listed below will appear when
Remote Access
is set to
[Enabled].
COM1
Serial Port Number
COM2
Select Serial Port for console
redirection. Make sure the selected
port is enabled.
Base Address, IRQ
Read only
115200 8, n, 1
57600 8, n, 1
38400 8, n, 1
19200 8, n, 1
Serial Port Mode
9600 8, n, 1
Select Serial Port settings.
None
Hardware
Flow Control
Software
Select Flow Control for console
redirection.
Disabled
Boot Loader
Redirection After
BIOS POST
Always
Disable: Turns off the redirection
after POST
Boot Loader: Redirection is active
during POST and during Boot
Loader.
Always: Redirection is always
active.
<Some OSs may not work if set to
Always>
ANSI
VT100
Terminal Type
VT-UTF8
Select the target terminal type.
Enabled
VT-UTF8 Combo
Key Support
Disabled
Enable VT-UTF8 Combination key
Support for ANSI/VT100 terminals.
No Delay
Delay 1 Sec
Delay 2 Sec
Sredir Memory
Display Delay
Delay 4 Sec
Gives the delay in seconds to
display memory information
Summary of Contents for S7025
Page 2: ...http www tyan com 2...
Page 4: ...http www tyan com 4 Appendix How to Make a Driver Diskette 76 Glossary 78 Technical Support 84...
Page 11: ...http www tyan com 11...
Page 14: ...http www tyan com 14 2 2 Block Diagram S7025 Block Diagram...
Page 37: ...http www tyan com 37...
Page 75: ...http www tyan com 75...