background image

http://www.tyan.com

 

Safety Information 

 

Retain and follow all product safety and operating instructions provided 
with your equipment. In the event of a conflict between the instructions in 
this guide and the instructions in equipment documentation, follow the 
guidelines in the equipment documentation. 

Observe all warnings on the product and in the operating instructions. To 
reduce the risk of bodily injury, electric shock, fire and damage to the 
equipment, observe all precautions included in this guide. 

You must become familiar with the safety information in this guide before 
you install, operate, or service TYAN products. 

 

Symbols on Equipment 

 

Caution

. This symbol indicates a potential hazard. 

The potential for injury exists if cautions are not 
observed. Consult equipment documentation for 
specific details. 

 

Caution.

 Slide-mounted equipment is not to be 

used as a shelf or a work space.

   

 

Warning.

 This symbol indicates the presence of 

hazardous energy circuits or electric shock 
hazards. Refer all servicing to qualified personnel.

 

Warning

. This symbol indicates the presence of a 

hot surface or hot component. If this surface is 
contacted, the potential for injury exists. 
To reduce risk of injury from a hot component, 
allow the surface to cool before touching. 

 
General Precautions 

· 

Follow all caution and warning instructions marked on the equipment and 

explained in the accompanying equipment documentation. 

 

 

Machine Room Environment 

· 

This device is for use only in a machine room or IT room. 



· 

Make sure that the area in which you install the system is properly 

ventilated and climate-controlled. 

Summary of Contents for FT48B-B7100

Page 1: ...1 http www tyan com FT48B B7100 Service Engineer s Manual...

Page 2: ...2 http www tyan com...

Page 3: ...ing liability or warranties relating to fitness for a particular purpose or merchantability MITAC retains the right to make changes to produce descriptions and or specifications at any time without no...

Page 4: ...sed in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which...

Page 5: ...ollowing parts Chapter 1 Overview This chapter provides an introduction to the TYAN FT48B B7100 barebones and standard parts list describes the external components gives an overview of the product fro...

Page 6: ...the purpose of this pin If your outlet does not support this kind of plug contact your electrician to replace your obsolete outlet Do not place anything on the power cord Place the power cord where it...

Page 7: ...The potential for injury exists if cautions are not observed Consult equipment documentation for specific details Caution Slide mounted equipment is not to be used as a shelf or a work space Warning...

Page 8: ...nees bent Equipment Racks To avoid injury or damage to the equipment Observe local occupational health and safety requirements and guidelines for manual materials handling Do not attempt to move a rac...

Page 9: ...l cause restricted airflow and might cause damage to the equipment Make sure the product is properly matted with the rails Products that are improperly matted with the rails might be unstable Verify t...

Page 10: ...empt to recharge the battery Dispose of used batteries according to the instructions of the manufacturer Do not dispose of batteries with the general household waste To forward them to recycling or pr...

Page 11: ...product sustains damage requiring service disconnect the product from the AC electrical outlet and refer servicing to an authorized service provider Examples of damage requiring service include The po...

Page 12: ...Opening the Chassis Front Bezel 31 2 1 3 Installing the CPU and Heatsink 32 2 1 4 Installing the Expansion Cards 35 2 1 5 Installing the Memory 38 2 1 6 Installing Hard Drives 41 2 2 Rack Mounting 43...

Page 13: ...on Board Features 68 3 7 2 Pin Definitions 69 3 8 Replacing the Power Backplane Board 71 3 8 Removing the Motherboard 73 Appendix I How to recover UEFI BIOS for Intel Xeon Scalable Processor based Pla...

Page 14: ...http www tyan com 14 NOTE...

Page 15: ...ble 32 and 64 bit computing high bandwidth memory design and lightning fast PCI E bus implementation The FT48B B7100 not only empowers your company in nowadays IT demand but also offers a smooth path...

Page 16: ...upported HDD SSD Interface 10 SATA 6Gb s System Cooling Configuration FAN 5 1 12cm fans Redundancy Yes Power Supply Type RPSU Input Range AC 100 127V 12A AC 200 240V 9 48A Output Watts 1000 Watts Max...

Page 17: ...orts Controller Intel I350 AM2 Storage SATA Connector 3 Mini SAS HD 12 ports 2 SATA III totally support 14 ports Controller Intel C621 Speed 6 0 Gb s RAID RAID 0 1 10 5 Intel RSTe M 2 connector 1 M 2...

Page 18: ...deo compression 10 100 1000 Mb s MAC interface BIOS Brand ROM size AMI 32MB Feature Hardware Monitor SMBIOS 3 0 PnP Wake on LAN Boot from USB device PXE via LAN Storage User Configurable FAN PWM Duty...

Page 19: ...00GM2NR Motherboard pre installed 1 M1019 FPB Front Panel Board pre installed 1 M7100F48B PDB Power Distribution Board pre installed 1 M7063F86 PBP Power Backplane Board pre installed 1 M1801F77 FB FT...

Page 20: ...tyan com 20 1 5 About the Product The following views show you the product 1 5 1 System Front View 1 HDD0 2 HDD1 3 HDD2 4 HDD3 5 HDD4 6 HDD5 7 HDD6 8 HDD7 9 M1019 FPB Front Panel Control Board pre in...

Page 21: ...tyan com 21 M1019 FPB Front Panel Control Board 1 Power Button 2 Reset Button 3 NMI Button 4 ID Button 5 LAN2 LED 6 LAN1 LED 7 HDD LED 8 Warning LED 9 Power LED 10 ID Button 11 USB3 0 Port 2 12 USB3...

Page 22: ...Board pre installed 3 RPSU1 4 RPSU0 5 ID LED Button 6 USB3 0 Ports 7 USB3 0 Ports 8 LAN2 9 LAN1 BMC 10 VGA Port 11 PCIE Gen3 x16 Slot PCIE 7 GPU4 12 PCIE Gen3 x8 Slot PCIE 6 13 PCIE Gen3 x16 Slot PCIE...

Page 23: ...Failed Voltage Thermal Alert ID LED LED State Color Description ID LED On Blue System identified Off Off System not identified NOTE Press ID button when the system is AC Alternating Current on then ID...

Page 24: ...n The two 2 onboard Ethernet ports have green and yellow LEDs to indicate LAN status The chart below illustrates the different LED states RJ45 LAN Link Activity LED Scheme Left LED Link Activity Right...

Page 25: ...F77 FB FT48 Fan Board pre installed 12 M7063F86 PBP Power BP Board pre installed 3 FAN1 13 2 HDD trays with M7063F86 BP6 2 HDD BP Board pre installed 4 FAN2 14 PCIE Gen3 x16 PCIE 1 GPU1 5 FAN3 15 PCIE...

Page 26: ...http www tyan com 26 NOTE...

Page 27: ...an prevent you from accidentally damaging the internal components 2 0 3 Tools The following procedures require only a few tools including the following A cross head Phillips screwdriver A grounding st...

Page 28: ...d touching motherboard components IC chips connectors memory modules and leads The motherboard is pre installed in the system When removing the motherboard always place it on a grounded anti static su...

Page 29: ...therboard including CPUs memory modules HDD SSD and PCI E cards 2 1 1 Removing the Chassis Cover and Air Ducts Follow these instructions to remove the FT48B B7100 chassis cover and air ducts 1 Unscrew...

Page 30: ...http www tyan com 30 3 Unscrew to remove the air ducts from the chassis...

Page 31: ...sis Front Bezel Follow the following instructions to open the chassis front bezel 1 Insert the front bezel key packed in a bag in the accessory box and rotate the key 90 degrees counterclockwise to un...

Page 32: ...ing CPUs and CPU heatsinks 1 Align and install the processor on the carrier 2 Locate the CPU socket s gold arrow Always start with CPU0 first Remove the CPU Socket protection cap 3 Install the carrier...

Page 33: ...http www tyan com 33...

Page 34: ...k with the CPU socket by the guide pins and make sure the gold arrow is located in the correct direction Then place the heatsink onto the top of the CPU socket 5 To secure the heatsink use a T30 Secur...

Page 35: ...n expansion slots Only the PCI E Gen 3 x16 slots can support GPU Graphic Processing Unit cards Follow these instructions to install the GPU card 1 Locate the PCI E Gen 3 x16 slots on the motherboard U...

Page 36: ...http www tyan com 36 3 Connect the GPU Power cable 4 Insert the GPU card into the PCIE Gen 3 slot and screw the GPU card to the chassis...

Page 37: ...http www tyan com 37 5 Insert the cable through the air duct opening and place the GPU air duct in place 6 Screw the GPU air duct to the chassis...

Page 38: ...emory slot locking levers in the direction of the arrows as shown in the following illustration 2 Align the memory module with the slot When inserted properly the memory slot locking levers lock autom...

Page 39: ...http www tyan com 39...

Page 40: ...ot 2 Use paired memory installation for max performance 3 Populate the same DIMM type in each channel specifically Use the same DIMM size Use the same of ranks per DIMM Dual CPU installed CPU0 and CPU...

Page 41: ...ont two at rear Follow these instructions to install a hard drive Warning Always install the HDD SSD to the chassis after the chassis is secured on the rack 1 Press the locking lever latch and pull th...

Page 42: ...Place a hard drive into the drive tray Use four screws to secure the HDD SSD 5 Reinsert the HDD tray into the chassis 6 Press the locking lever to secure the hard drive Repeat the same procedures to i...

Page 43: ...for M6 screw 10 pcs B M 6 10 pcs C M 4 L5 16 pcs 2 2 1 Installing the Server in a Rack Follow these instructions to mount the TYAN FT48B B7100 into an industry standard 19 rack NOTE Before mounting t...

Page 44: ...Screw the mounting ears to the FT48B B7100 as shown using six M4 L5 screws C from the supplied screw kit 2 Press the latch to draw out the inner rails from each rail assembly 3 Install the inner slidi...

Page 45: ...gth of the rack The sliding brackets have long slits to allow them to be fixed to the other part of the rails in various positions 2 Secure the outer rails to the rack using four M6 2 front 2 rear scr...

Page 46: ...46 http www tyan com Rack Mounting the Server 1 Draw out the middle rail to the latch position 2 Lift the unit and then insert the inner slide rails into the middle rails 3 Push the whole system in...

Page 47: ...47 http www tyan com 4 Secure the mounting ears of the unit to the rack using three M6 screws B for each side 5 Secure the screws on the rear side...

Page 48: ...48 http www tyan com NOTE...

Page 49: ...components including the S7100 Motherboard M1019 FPB Front Panel Board M1244G70 BP6 8 M7063F86 BP6 2 SATA SAS HDD Backplane Board M1081F77 FB FB48 Fan Board M7100F48B PDB Power Distribution Board PCI...

Page 50: ...remove the chassis cover Follow Section 2 1 1 Removing the Chassis Cover page 29 to remove the cover of the FT48B B7100 3 2 Replacing the System Fan Follow these instructions to replace the system fa...

Page 51: ...51 3 3 Replacing the Fan Board Follow these instructions to replace the fan board 1 Unscrew the fan cage and remove all system fans from the fan cage 2 Take out the fan cage 3 Disconnect all cables f...

Page 52: ...http www tyan com 52 4 Unscrew the fan board to replace a new one 5 Assemble the fan cage and system fans back into the chassis following the steps described earlier in reverse...

Page 53: ...Fan Connector 1 20 pin Fan Control Header 1 4 pin Fan Signal Control Header 1 FAN1 Connector J1 7 Big 4 pin Power Connector PW1 2 FAN2 Connector J2 8 Big 4 pin Power Connector PW2 3 FAN3 Connector J3...

Page 54: ...http www tyan com 54 3 3 2 Fan Board LED Definition FAN Status Green LED Red LED With Fan Speed RPM OK On Off Fan Failed or Without Fan Off On...

Page 55: ...D 1 2 VDD 12V TACH 3 4 PWM PW1 PW2 PW3 Big 4 pin Power Connector Definition Pin Pin Definition VDD 12V 1 2 GND GND 3 4 NC J8 Fan Control Header Definition Pin Pin Definition TACH1 1 2 TACH6 TACH2 3 4...

Page 56: ...d M7063F86 BP6 2 HDD Backplane Boards M1244G70 BP6 8 Front HDD BP Board 1 Refer to Section 3 3 Replacing the Fan Board p 51 on how to remove the Fan Cage and Fan Board 2 Disconnect all cables attached...

Page 57: ...http www tyan com 57 5 Loosen the screws as shown 6 Unscrew the HDD BP Board for replacement 7 Prepare a new HDD BP Board and reinstall it into the chassis following the steps in reverse...

Page 58: ...6 2 Rear HDD BP Board 1 Disconnect all cables attached to the HDD BP Board Unscrew the HDD BP Board from the HDD module 2 Prepare a new HDD BP Board for replacement and reinstall it into the HDD modul...

Page 59: ...4 1 HDD BP Board Features Front view Rear view M1244G70 BP6 8 HDD Backplane Board Form Factor 8 layer PCB Integrated I O 1 8 pin Power Connector PW3 2 Mini SAS Connector 8 HDD Connector 2 5 SAS SATA 1...

Page 60: ...tyan com Front view Rear view M7063F86 BP6 2 HDD Backplane Board Form Factor 8 layer PCB Integrated I O 1 Big 4 pin Power Connector PW2 2 7 pin SATA Connector 2 HDD Connector 2 5 SAS SATA 6Gb s hot s...

Page 61: ...1244G70 BP6 8 HDD Backplane Board PW3 8 pin Power Connector Definition Pin Pin Definition GND 1 5 12V GND 2 6 12V GND 3 7 12V GND 4 8 12V M7063F86 BP6 2 HDD Backplane Board PW2 Big 4 pin Power Connect...

Page 62: ...the Front Panel Board Follow these instructions to replace the M1019 FPB Front Panel Control Board 1 Disconnect the power cable and data cable from M1019 2 Push aside the latch and slide the LED cont...

Page 63: ...m 63 3 Remove three screws securing the LED control board to the bracket 4 Lift the LED control board free from the chassis After replacement insert the unit into the chassis following the above proce...

Page 64: ...ont Panel Control Board 1 Power Button 8 Warning LED red 2 Reset Button 9 Power LED green 3 NMI Button 10 ID Button 4 ID LED blue 11 USB3 0 Port 2 5 LAN2 LED green 12 USB3 0 Port 1 6 LAN1 LED green 13...

Page 65: ...GND 7 14 P1_TX_P P0_N 8 13 GND P0_P 9 12 P1_N OC_N 10 11 P1_P J3 24 pin Front Panel Header Signal Pin Pin Signal PW_LED 1 2 FP_PWER 3 3V KEY 3 4 FP_ID_LED_PWR PW_LED 5 6 FP_ID_LED_N HD_LED 7 8 HWM_FAU...

Page 66: ...Power Supply Units Please unplug the power cord before you follow these instructions to replace the power supply units 1 Press and hold the latch to pull the power supply out 2 After replacing a new...

Page 67: ...Power Distribution Board 1 Disconnect the all cables from the power distribution board 2 Unscrew the power distribution board 3 Push the power supply cage forwards to take out the power distribution...

Page 68: ...Board Features M7100F48B PDB Power Distribution Board Board Size 82mm x 127 3mm 6 layer PCB Integrated I O 3 8 pin power connector 3 4 pin power connector 2 20 pin power connector 1 24 pin power conn...

Page 69: ...Connector Definition Pin Pin Definition GND 1 2 GND 12V 3 4 5V PW6 PW7 PW8 8 pin Power Connector Definition Pin Pin Definition GND 1 5 12V GND 2 6 12V GND 3 7 12V GND 4 8 12V PW2 PW3 20 Pin Power Conn...

Page 70: ...0 PW5 24 pin Power Connector Definition Pin Pin Definition 3 3V 1 13 3 3V 3 3V 2 14 NA GND 3 15 GND 5V 4 16 PS_ON GND 5 17 GND 5V 6 18 GND GND 7 19 GND PW_GD 8 20 NA 5VSB 9 21 5V 12V 10 22 5V 12V 11 2...

Page 71: ...Replacing the Power Backplane Board Follow these instructions to replace the M7063F86 PBP Power Backplane Board 1 Unscrew the Power BP Board Tray from the chassis 2 Remove the power distribution board...

Page 72: ...backplane board tray 4 Slide to take out the power backplane board tray 5 Unscrew to replace with a new power backplane board 6 Follow the steps described earlier in reverse order to reinstall the pow...

Page 73: ...herboard 1 Make sure you have disconnected all cables and remove all components from the chassis 2 Unscrew the motherboard 3 Carefully lift the motherboard from the tray 4 Prepare a new motherboard an...

Page 74: ...http www tyan com 74 NOTE...

Page 75: ...f from working In no event shall Tyan be liable for direct indirect incidental special or consequential damages arising from the BIOS update or recovery The BIOS Recovery file is named xxxx cap where...

Page 76: ...the server during the BIOS recovery process This can damage the BIOS recovery bootloader and prevent it from loading a subsequent time 7 Wait for the BIOS recovery procedure to complete Completion is...

Page 77: ...Mini SAS HD Cable M1244G70 BP 6 8 BP Board Connect to S7100 MB Mini SAS HD Cable 1 J9 SAS0_3 Mini SAS HD Cable 2 J10 SAS4_7 3 SATA and SGPIO Cable M7063F86 BP6 2 BP Board Connect to S7100 MB SATA cabl...

Page 78: ...MB FP Ctrl Cable J3 SSI_FP USB3 0 Cable J34 USB3_FPIO2 7 GPU PWR Cable PDB Board to GPU Card PDB Board Connect to GPU card GPU PWR Cable 1 PW2 GPU card 1 GPU PWR Cable 2 GPU card 2 GPU PWR Cable 3 PW3...

Page 79: ...explanation is also included for readers reference NOTE The red dot indicates the sensor Fan and Temp Sensor Location 1 Fan Sensor It is located in the third pin of the fan connector which detects the...

Page 80: ...http www tyan com 80 BIOS Temp Sensor Name Explanation...

Page 81: ...CPU0 DIMM channel C slot P0_MC1_DIM_CH_D The highest temperature of CPU0 DIMM channel D slot P0_MC1_DIM_CH_E The highest temperature of CPU0 DIMM channel E slot P0_MC1_DIM_CH_F The highest temperature...

Page 82: ...perature of CPU1_DIMM_MOS_1 CPU1_DIMM_MOS_2 Temperature of CPU1_DIMM_MOS_2 CPU0_FAN Fan speed of CPU0_FAN CPU1_FAN Fan speed of CPU1_FAN SYS_FAN1 Fan speed of SYS_FAN1 SYS_FAN2 Fan speed of SYS_FAN2 S...

Page 83: ...2 TF FAN 12V PFC1212DE SP0 4800RPM 120X120 X38 DELTA 4 pin Heatsink Cooler FRU TH 0220 343T56600001 HF HEATSINK SBU AL CU SOLDERLING PIPE 3647 2U NARROW PASSIVE HEATSINK 1A0 D042800991 108 0X78 0X64 0...

Page 84: ...http www tyan com 84 NOTE...

Page 85: ...expectations TYAN s website http www tyan com provides easy to access resources such as in depth Linux Online Support sections with downloadable Linux drivers and comprehensive compatibility reports f...

Page 86: ...oper maintenance of products NOTE A receipt or copy of your invoice marked with the date of purchase is required before any warranty service can be rendered You may obtain service by calling the manuf...