7
Aftercare and Spout Removal
Periodically the spout and nozzle should be removed,
cleaned and disinfected to remove any build up of
debris, deposits or bio film which may affect the
performance of the tap.
Ensure the tap is turned off before commencing.
Using a suitably sized spanner remove the nozzle (3)
from the spout.
Unscrew the grub screw (4) and pull the spout (2) from
the tap body (1).
Throughly clean and disinfect the nozzle and spout.
Check the condition of the ‘O’ ring on the tap body if
damage replace with a new one.
To ease assembly lubricate the ‘O’ ring with a WRAS approved silicone based grease.
Re-assemble in the reverse order.
Twyford taps have a high quality finish and should be treated with care.
An occasional wipe with a mild washing-up liquid on a soft damp cloth followed by a thorough
rinsing is all that is required.
Do not use
an
abrasive
or
chemical household cleaner
as this may
cause damage
.
Cartridge Replacement
Isolate both the hot and cold water supplies
Remove the indice (5), and unscrew retaining screw (6).
Remove the handle (7) and the temperature stop rings (8).
Using a suitable spanner unscrew the cartridge (9).
Replace with a new cartridge and assemble in the reverse
order.
Re-calibrate following the procedure in the Calibration
section
5
6
7
8
9
1
2
3
4