BASIC INSTALLATION GUIDELINES
TWT-POUS-300 / TWT-POUE-400
• Securely mount system using pre-drilled holes on beverage dispensing machine(s) or near
water feed line (POU/POE) in an area a l l owing enough room on all sides of system for filter
replacement, visual inspection, keeping it out of harms way (i.e., appropriate service c l e a r a n c e s ) .
• Shut off water before you start installation at Point-of-Use
• Plumb system into to water feed line
• Test System
• Do not plug in system
• Close drain ports
• Open shut-off valves, test for leaks
• Tighten all connectors
• System should now be ready for operation
• Plug into VAC outlet, make sure manual shut off valves and drain ports are in
proper position for water flow
• Allow system to operate for several minutes before using or drinking water
COMPONENTS
One-
factory assembled and mounted system
One-
spanner filter wrench for filter replacement
One-
owner’s installation and maintenance manual (read before installation )
THINGS TO DO PERIODICALLY
Not less than weekly
1. TWT-POUS-300 Unplug AC power cord(s) before any repairs and/or replace
ments are performed
• Visually inspect deposit controller to ensure continuous operation
• Deposit control system LED lights should be on
• Make sure the filters are free flowing, if they become clogged you must clean or
replace them
• Replace sediment and/or carbon filters when needed, generally 2 to 3 times a year,
depending on water use, quality, and con
d
itions.*
• Replace resin filter and reset meter every 150 to 200 gallons of processed fluid (up
to 20 grains), above 20 grains hardness to be determined* (will vary based on
equipment operating conditions, water quality in different areas of country.
Manufactures suggest equipment owners replace resin filters more frequently until
they have established appropriate usage and time tables).
See flow meter next page
• Water Source (municipal/well), condition and GPM determines need (hard water
areas of the country may require more frequent filter replacements).
• Use filter wrench (shipped with system) when replacing filters
2. TW T-POUE-400 Unplug AC power cord(s) before any repairs and/or
replacements are performed:
• Visually inspect deposit controller to ensure continuous operation
• Deposit control system LED lights should be on
• Make sure the filters are free flowing, if they become clogged you must clean or
replace them
• Replace filters when needed, generally 2 to 3 times a year, depending on water
use, quality, and con
d
itions.*
Meter Setting Guidelines POUE-400 (Non-Resin Filter Use):
• Set meter to max 19,900 gallons of processed water, based on a family of 4 or
less, you should be able to reset meter to 19,900 again before filter replacement is
needed. It is estimated the average person uses between 60 to 100 gallons of
water per day (will vary based on equipment operating conditions, water quality in
different areas of country. Manufactures suggest equipment owners replace filters
more frequently until they have established appropriate usage and time tables).
• Water Source (municipal/well), condition and GPM determines need (hard water
areas of the country may require more frequent filter replacements).
• Use filter wrench (shipped with system) when replacing filters
*
TWT Inc. recommends that owners periodically test their water and that an initial supply of replacement
products e.g., replacement filters, be stored at owners facility at all times, that will insure uninterrupted
service and treatment.
SYSTEM MAINTENANCE
Before any maintenance and/or replacement of filters
is performed, follow these necessary and important steps:
1. Unplug Power Cord
2. Close inflow & outflow shut-off valves
3. Open drain port, allowing water to drain
4. Press down pressure release valve on top of filter assembly, allowing
additional drainage
5. Allow enough time for system to drain fully–
It is now safe to perform mainten-
ance, after performing maintenance, take these necessary and important steps:
6. Close drain port
7.Open inflow and outflow valves
8. Plug in Power Cord
FILTER REPLACEMENT
1. Replace filters when needed
2. Replace sediment, carbon and/or GAC/KDF-55 filters when needed, generally 2 to 3
times a year, depending on water use, quality, and con
d
itions.*
3. Replace resin filter every 150 to 200 gallons of processed fluid (up to 20 grains),
above 20 grains hardness to be determined (will vary based on equipment operating
conditions, water quality in different areas of country. Manufactures suggest
equipment owners replace resin filters more frequently until they have established
appropriate usage and time tables).
4. Shut down system before performing any maintenance.
READ CAUTION LABEL
5. Turn off water supply to system.
6. Depress pressure release button to relieve pressure in filter housing.
7. Unscrew filter housings using spanner wrench (shipped with system ).
N OT E :
When opening filter housing (see diagram below)to change cartridge, it is
common for O-ring/Gasket to lift out of housing and stick to cap (remove carefully.)
TW T-POUS-300 & POUE-400 Integrated Treatment System
Ap p r ox Size 26"L X 20"H X 10"D • Approx weight 40 lbs.(will va ry based on filtrs used)
Systems engineering design, weight, size and system component assembly may vary based on TWT engineering review.
O-Ring
Gasket
Spanner
Wrench
Filter Housing
Pressure Release
Mounting Bracket
Filter
Cartridge
Filter Head
Filter systems, sizes and cartridges
will vary based on capacity and
application needs.
Basic procedures for replacement of
cartridges are the same as illustrated
Continue Filters
Flow Meter
1/2" In & Out
Piping
Manual Shut-Off
Valves
TWT Deposit Controller
TWT Reaction Chamber
Staged Filtration
Drain
Por t
Pressure Release
Valves