TWINBIRD SC-UB04 Operation Manual Download Page 15

Ref.  No.:  SCDD-090011 

 

 

   

TWINBIRD CORPORATION 

http://fpsc.twinbird.jp

 

(15/17) 

side temperature to below 65 deg. 

 

SW2 状態 

SW2 Value 

0000 

0001 

0010 

0011 

0100 

0101 

0110 

0111 

設定温度 

Temperature Limit 

+50℃  +52

  +54

  +56

  +58

  +60

  +62

  +64

 

SW2 状態 

SW2 Value 

1000 

1001 

1010 

1011 

1100 

1101 

1110 

1111 

設定温度 

Temperature Limit 

+66℃  +68

  +70

  +72

  +74

  +76

  +78

  +80℃ 

 

5.9  異常信号出力  Emergency signal output 

(1) 

異常の条件

 

Emergency situations

 

次のいずれかの場合、

FPSC

への電圧出力を停止し、異常信号出力端子

(CN7-#5)

より出力しま

す。

 

In the following situations, power supply to the FPSC will be stopped and an emergency signal will 

be output from the signal output terminal (CN7-#5). 

 

①排熱側温度センサーの温度が、

SW2

で設定された排熱側温度上限に達した。

 

Temperature sensor at warm side has reached the limit temperature set by SW2.

 

FPSC

が接続されていないか、又は、断線した。

 

FPSC disconnected or the input power wire is cut.

 

③排熱側温度センサーが接続されていないか、又は、断線した。

 

Temperature sensor at warm side is disconnected or wire is cut.

 

④入力電源電圧が範囲外である。

 

The power source voltage is out of allowable range.

 

(入力電源電圧

 

 9.6V

  又は  入力電源電圧

 

 14.0V

 

(Power source voltage < 9.6 V  or  Power source voltage > 14.0 V) 

 

No. 

出力信号

 Output 

状  態

 Status 

High 

異  常

 

Emergency 

Low 

正  常

 

Normal 

 

(2)異常信号出力停止条件 

Condition for cancellation of the emergency signal output

 

運転/停止信号が停止になった時 

When the on / off signal goes off. 

 

 

 

 

Summary of Contents for SC-UB04

Page 1: ...Ref No SCDD 090011 TWINBIRD CORPORATION http fpsc twinbird jp 1 17 Operation Manual Model SC UB04 Name 40W FPSC H 40W FPSC Module H SC TWINBIRD CORPORATION SC Business Operation...

Page 2: ...infringement which could result in legal action against the infringing party 10 USA REEXPORT CONTROL CCL ECCN 6A002 d 2 a Cryocoolers for Optical sensors 2008 1 The following regulations shall apply t...

Page 3: ...e FPSC Module To avoid the possibility of damaging to internal parts by overheating the FPSC Module do not apply heating elements directly to the cold side 4 Use caution when handling the Heat Reject...

Page 4: ...tion 13 FPSC Please provide thermal insulation around cold side to prevent frost and dew condensation If conditions require that you need to operate the FPSC Module without thermal insulation the cold...

Page 5: ...90 x H 280 mm 2 Weight Approximately 3 kg 3 Refrigerant He Helium 4 Amount of Refrigerant 2 5 g 5 Inside Pressure of Stirling Cooler 2 6 Mpa 6 Power Source DC 12 V for Drive PCB 7 Cooling Capacity 40W...

Page 6: ...f No SCDD 090011 TWINBIRD CORPORATION http fpsc twinbird jp 6 17 Graph of Cooling Capacity Cold Side Temperature Condition Ambient Temperature 25 Cooling Capacity W 60 40 20 0 20 0 10 20 30 40 50 60 7...

Page 7: ...Ref No SCDD 090011 TWINBIRD CORPORATION http fpsc twinbird jp 7 17 Main Size mm...

Page 8: ...N OFF 3 CN8 AC 2 0 8 5 V 4 1 0 3 1 0 High Low 2 1 0 4 1 1 0 High Low 5 1 High Low 6 2 High Low 7 8 0V 9 5V DC 5 0 V 10 50 mA CN2 JST B2B PH K E JST PHR 2 1 2 CN6 JST B2B PH K S JST PHR 2 1 2 0 0 3 V 5...

Page 9: ...gh Low 6 Status Alarm Normal Alarm Signal 2 Output Output High Low 7 Status Alarm Normal 8 0V 9 5V Reference Voltage Output Output Voltage DC 5 0 V 10 Output Current Capacity 50 mA CN2 JST B2B PH K E...

Page 10: ...o the control terminal 3 FPSC FPSC DIP SW After initial start up of the FPSC the driving voltage increases in steps at a speed determined by the DIP switch settings 4 FPSC 7A Controls output voltage i...

Page 11: ...ignal is out of the allowed range Power source CN1 Connect power source to power input terminal CN1 No Item Specification 1 Rating voltage DC 12 V 2 Allowable voltage DC 10 8 13 2 V DC 12 V 10 3 Maxim...

Page 12: ...DC 5V Low GND 47k DC 5V Signal input terminal is connected to 5V DC through 47 k ohm resistor on PCB Setting of output CN7 Pin 1 CN7 Pin 2 3 FPSC Output voltage is decided by input voltage CN7 Pin 1 o...

Page 13: ...V 2 sec 0 1 V 5 sec 0 1 V 10 sec 0 1 V 15 sec 0 1 V 20 sec 0 1 V 25 sec 0 1 V 30 sec SW1 SW1 value 1000 1001 1010 1011 1100 1101 1110 1111 Ramp speed of output voltage 0 1 V 35 sec 0 1 V 40 sec 0 1 V...

Page 14: ...CN2 FPSC SW2 FPSC 54 0010 FPSC SC UB04 FPSC 65 FPSC 65 The PCB detects insufficient heat rejection for FPSC using connected warm side thermistor connected to CN2 Limitation of temperature can be set a...

Page 15: ...s power supply to the FPSC will be stopped and an emergency signal will be output from the signal output terminal CN7 5 SW2 Temperature sensor at warm side has reached the limit temperature set by SW2...

Page 16: ...on for cancellation of the alarm signal 1 output When the temperature of the sensor on the warm side goes down 5 deg C lower than the temperature set by DIP switch Alarm signal 2 1 2 Situation for ala...

Page 17: ...C E mail sc twinbird co jp Tel 0256 92 6173 Fax 0256 93 6168 959 0292 2084 2 Contact TWINBIRD CORPORATION SC Business Operation E mail sc twinbird co jp Phone 81 256 92 6173 Facsimile 81 256 93 6168 A...

Reviews: