次の状態検出時に、所定の端子より警告信号を出力します。

 

Generating an alarm signal from prescribed terminal when the following conditions are detected.

 

①排熱部に設置した温度センサーの温度が、

DIP SW

で設定された温度よりも

5

℃低い温度に達

した。

 

When  the  temperature  of  the  sensor  on  the  warm  side  reaches  5  deg  C  lower  than  the 

temperature setting of the DIP switch.

 

FPSC

への出力設定信号のレベルが規定の範囲外である。

 

When the level of output set signal is out of the allowed range.

 

 

5.2  電源  Power source 

電源入力端子

(CN1)

に電源を接続します。

 

Connect power source to power input terminal (CN1). 

No. 

項  目

 Item 

仕  様

 Specification 

定格電圧

 

Rating voltage 

DC 12 V 

許容電圧範囲

 

Allowable voltage 

DC 10.8 ~ 13.2 V (DC 12 V ± 10 %) 

最大入力電流

 

Maximum input current 

6A (RMS)(12V 入力時) 

(at 12 V of input voltage)

 

 

5.3  FPSC への出力  Output to FPSC 

FPSC

出力端子

(CN8)

より、

FPSC

へ駆動電圧を出力します。

 

Drive voltage to FPSC is supplied from FPSC output terminal (CN8). 

No. 

項  目

 Item 

仕  様

 Specification 

出力波形

 

Output wave shape 

PWM

波形

 

PWM 

基本周波数

 

Frequency 

79.1Hz 

キャリア周波数

 

Carrier frequency 

5.0635 kHz 

出力電圧範囲

 

Output voltage range 

AC 2.0~8.5 V (RMS) @79.1Hz 

最大出力電流

 

Output current capacity 

A (RMS) 

 

 

 

 

 

 

 

 

Summary of Contents for SC-UB04

Page 1: ...Ref No SCDD 090011 TWINBIRD CORPORATION http fpsc twinbird jp 1 17 Operation Manual Model SC UB04 Name 40W FPSC H 40W FPSC Module H SC TWINBIRD CORPORATION SC Business Operation...

Page 2: ...infringement which could result in legal action against the infringing party 10 USA REEXPORT CONTROL CCL ECCN 6A002 d 2 a Cryocoolers for Optical sensors 2008 1 The following regulations shall apply t...

Page 3: ...e FPSC Module To avoid the possibility of damaging to internal parts by overheating the FPSC Module do not apply heating elements directly to the cold side 4 Use caution when handling the Heat Reject...

Page 4: ...tion 13 FPSC Please provide thermal insulation around cold side to prevent frost and dew condensation If conditions require that you need to operate the FPSC Module without thermal insulation the cold...

Page 5: ...90 x H 280 mm 2 Weight Approximately 3 kg 3 Refrigerant He Helium 4 Amount of Refrigerant 2 5 g 5 Inside Pressure of Stirling Cooler 2 6 Mpa 6 Power Source DC 12 V for Drive PCB 7 Cooling Capacity 40W...

Page 6: ...f No SCDD 090011 TWINBIRD CORPORATION http fpsc twinbird jp 6 17 Graph of Cooling Capacity Cold Side Temperature Condition Ambient Temperature 25 Cooling Capacity W 60 40 20 0 20 0 10 20 30 40 50 60 7...

Page 7: ...Ref No SCDD 090011 TWINBIRD CORPORATION http fpsc twinbird jp 7 17 Main Size mm...

Page 8: ...N OFF 3 CN8 AC 2 0 8 5 V 4 1 0 3 1 0 High Low 2 1 0 4 1 1 0 High Low 5 1 High Low 6 2 High Low 7 8 0V 9 5V DC 5 0 V 10 50 mA CN2 JST B2B PH K E JST PHR 2 1 2 CN6 JST B2B PH K S JST PHR 2 1 2 0 0 3 V 5...

Page 9: ...gh Low 6 Status Alarm Normal Alarm Signal 2 Output Output High Low 7 Status Alarm Normal 8 0V 9 5V Reference Voltage Output Output Voltage DC 5 0 V 10 Output Current Capacity 50 mA CN2 JST B2B PH K E...

Page 10: ...o the control terminal 3 FPSC FPSC DIP SW After initial start up of the FPSC the driving voltage increases in steps at a speed determined by the DIP switch settings 4 FPSC 7A Controls output voltage i...

Page 11: ...ignal is out of the allowed range Power source CN1 Connect power source to power input terminal CN1 No Item Specification 1 Rating voltage DC 12 V 2 Allowable voltage DC 10 8 13 2 V DC 12 V 10 3 Maxim...

Page 12: ...DC 5V Low GND 47k DC 5V Signal input terminal is connected to 5V DC through 47 k ohm resistor on PCB Setting of output CN7 Pin 1 CN7 Pin 2 3 FPSC Output voltage is decided by input voltage CN7 Pin 1 o...

Page 13: ...V 2 sec 0 1 V 5 sec 0 1 V 10 sec 0 1 V 15 sec 0 1 V 20 sec 0 1 V 25 sec 0 1 V 30 sec SW1 SW1 value 1000 1001 1010 1011 1100 1101 1110 1111 Ramp speed of output voltage 0 1 V 35 sec 0 1 V 40 sec 0 1 V...

Page 14: ...CN2 FPSC SW2 FPSC 54 0010 FPSC SC UB04 FPSC 65 FPSC 65 The PCB detects insufficient heat rejection for FPSC using connected warm side thermistor connected to CN2 Limitation of temperature can be set a...

Page 15: ...s power supply to the FPSC will be stopped and an emergency signal will be output from the signal output terminal CN7 5 SW2 Temperature sensor at warm side has reached the limit temperature set by SW2...

Page 16: ...on for cancellation of the alarm signal 1 output When the temperature of the sensor on the warm side goes down 5 deg C lower than the temperature set by DIP switch Alarm signal 2 1 2 Situation for ala...

Page 17: ...C E mail sc twinbird co jp Tel 0256 92 6173 Fax 0256 93 6168 959 0292 2084 2 Contact TWINBIRD CORPORATION SC Business Operation E mail sc twinbird co jp Phone 81 256 92 6173 Facsimile 81 256 93 6168 A...

Reviews: