background image

E-1

CONSUMER SAFETY INFORMATION

PLEASE READ THIS MANUAL BEFORE INSTALLING

          AND OPERATING THIS APPLIANCE

WARNING!!

IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED

EXACTLY, AN ELECTRIC SHOCK OR FIRE MAY RESULT CAUSING

PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS 

AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.

E L E C T R I C   S T O V E   W I T H   H E A T E R

        HOMEOWNERS OPERATING MANUAL

    MODEL: DFS-500,DFS-500-2

V E N T F R E E D E C O R A T I V E   E L E C T R I C   S T O V E

Thank you and congratulations on your purchase of a Twin-Star International, Inc. 

stove. Please read the Installation & Operating Instructions before using this

appliance.

IMPORTANT: Read all instructions and warnings carefully before starting installation.

Failure to follow these instructions may result in a possible electric shock, fire hazard

and/or injury and will void the warranty.

 

Installation of Electric Fireplace, should take 15 minutes. The only tool required is a

Phillips head screwdriver, not supplied with this unit.

www.

twinstarhome.com

In English Call: 800-318-9373
In Spanish Call: 800-318-9374
 

For Customer Service:

WARNING: THIS IS AN UNVENTED, 

ELECTRIC APPLIANCE. DO NOT 

ATTEMPT TO BURN WOOD OR 

MANUFACTURED FIRELOGS IN OR 

ON THIS APPLIANCE OR GRATE.

Distributed by 
Twin-Star International, Inc. Under license. 
duraflame

TM

 and the duraflame flame 

logo are trademarks of Duraflame, Inc.

Twin-Star International, Inc.
Delray Beach, FL 33445
Made in China • Printed in China

Made in China

Printed in China

© 2012, Twin-Star International, Inc.

Summary of Contents for Duraflame DFS-500

Page 1: ...te www twinstarhome com L nea para llamadas en ingl s 800 318 9373 L nea para llamadas en espa ol 800 318 9374 STOP STOP PARE PARE ATTENTION SI VOUS AVEZ DES PROBL MES OU DES QUESTIONS ENVOYEZ UN COUR...

Page 2: ...appliance IMPORTANT Read all instructions and warnings carefully before starting installation Failure to follow these instructions may result in a possible electric shock fire hazard and or injury an...

Page 3: ...appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the current CSA C22 1 Canadian Electrical Code or for U S A installations fo...

Page 4: ...ng the fireplace If any part is missing or damaged do not attempt to use or plug in the power cord until the missing or damaged part is correctly replaced To avoid electric shock use only identical re...

Page 5: ...ly the fireplace will be on a dedicated circuit as other appliances on the same circuit may cause the circuit breaker to trip or the fuse to blow when the heater is in operation The unit comes standar...

Page 6: ...tion to work TEMPERATURE The Temperature control knob helps regulate the ambient temperature level The further the knob is rotated clockwise the higher the set point temperature Turning the knob count...

Page 7: ...he wall outlet 2 If fireplace has been operating let the unit cool at least 2 hours 3 Loosen the screws holding the stove back panel to the main body of stove see Fig 5 4 Pinch the spring clip to loos...

Page 8: ...ny maintenance or cleaning to reduce the risk of fire electrical shock or personal injury TROUBLESHOOTING PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION 1 No power switches do not light up 1 Power cord was...

Page 9: ...ion or other related costs expenses arising from defective part s repair replacement or otherwise of same will not be covered by this warranty nor shall the manufacturer assume responsibility for same...

Page 10: ...parato IMPORTANTE Lea todas las instrucciones y advertencias con detenimiento antes de comenzar la instalaci n Si no se siguen las instrucciones podr a provocarse riesgo de descarga el ctrica incendio...

Page 11: ...c digos locales con el C digo Canadiense de Electricidad vigente norma CSA C22 1 o para las instalaciones en EE UU de acuerdo con c digos locales y el C digo Nacional de Electricidad ANSI NFPA N 70 1...

Page 12: ...o ensamblando la chimenea Si falta alguna pieza o alguna pieza est da ada no intente usar o enchufar el cable el ctrico hasta repararla o reemplazarla Para evitar una descarga el ctrica utilice s lo...

Page 13: ...as las piezas Compare las piezas con la lista de contenidos del paquete y los diagramas incluidos anteriormente Si falta al guna pieza o si alguna pieza est da ada no intente armar instalar u operar e...

Page 14: ...ERATURA regula el nivel de temperatura del calentador Cuanto m s se gire la perilla en el sentido de las agujas del reloj mayor ser la temperatura de punto de ajuste Al girar la perilla en sentido opu...

Page 15: ...riente de pared 2 Si la chimenea ha estado en funcionamiento deje que la unidad se enfr e durante un m nimo de 2 horas 3 Afloje los tornillos que sujetan el panel posterior al cuerpo principal de la e...

Page 16: ...a el ctrica o lesiones personales SOLUCI N DE PROBLEMAS PROBLEMA CAUSA POSIBLE ACCI N CORRECTIVA 1 No hay alimentaci n los interruptores no encienden 1 El cable el ctrico no estaba enchufado en el tom...

Page 17: ...abricaci n transporte o de otro tipo que surja de la pieza defectuosa su reparaci n reemplazo u otra situaci n y el fabricante no asume ninguna responsabilidad por las mismas 7 El due o usuario asume...

Page 18: ...te www twinstarhome com L nea para llamadas en ingl s 800 318 9373 L nea para llamadas en espa ol 800 318 9374 STOP STOP PARE PARE ATTENTION SI VOUS AVEZ DES PROBL MES OU DES QUESTIONS ENVOYEZ UN COUR...

Reviews: