PACKAGE CONTENTS
CAUTION
To avoid injury from unexpected starting or electrical shock, do not plug the power cord into a
source of power during unpacking and assembly. The cord must remain unplugged whenever
you are adjusting/assembling the fireplace.
If any part is missing or damaged, do not attempt to use or plug in the power cord until the
missing or damaged part is correctly replaced. To avoid electric shock, use only identical
replacement parts when servicing double-insulated tools.
E-3
PRODUCT SPECIFICATIONS
VOLTAGE
AMPS
WATTS
120 VAC, 60 Hz
12.5 Amps
1500 Watts
PREPARATION
STOVE LOCATION
When choosing a location for your new stove, follow the instructions listed in the <IMPORTANT
INSTRUCTIONS> section in page 2.
Cold climate installation recommendation: When installing this unit against a
non-insulated exterior wall or chase, it is mandatory that the outer walls be insulated to
conform to applicable insulation codes.
ELECTRICAL CONNECTION
A 15-Amp, 120-V, 60 Hz circuit with a properly grounded outlet is required. Preferably, the fireplace will
be on a dedicated circuit as other appliances on the same circuit may cause the circuit breaker to trip or
the fuse to blow when the heater is in operation. The unit comes standard with 6-ft. (1.83 m) three-wire
cord, exiting from the rear of the fireplace. Avoid using an extension cord. If an extension cord must be
used, it must be a minimum 14 AWG, three wire with grounding type plug connector and rated not less
than 1875 Watts. The cord shall not be more than 20 feet (6 m) in length.