background image

ATTENTION

IF YOU HAVE ANY PROBLEMS OR QUESTIONS, EMAIL 

OR CALL CUSTOMER SERVICE BEFORE YOU RETURN 

THIS PRODUCT TO THE STORE WHERE IT WAS PURCHASED.

For Customer Service: email: [email protected]

in English Call: 866-661-1218

in Spanish Call: 866-661-1218

in French Call: 866-374-9203

ATENCIÓN

SI TIENE ALGÚN PROBLEMA O PREGUNTAS,

ENVÍE UN MENSAJE DE CORREO ELECTRÓNICO O LLAME AL SERVICIO 

DE ATENCIÓN AL CLIENTE ANTES DE DEVOLVER

ESTE PRODUCTO A LA TIENDA EN LA QUE LO COMPRÓ.

Servicio de atención al cliente: Correo electrónico: [email protected]

Línea para llamadas en inglés: 866-661-1218

Línea para llamadas en español: 866-661-1218

Línea para llamadas en francés: 866-374-9203

STOP

STOP

PARE

PARE

ATTENTION

SI VOUS AVEZ DES PROBLÈMES OU QUESTIONS, 

ENVOYEZ UN COURRIEL AU SERVICE À LA CLIENTÈLE OU APPELEZ LE 

SERVICE À LA CLIENTÈLE AVANT DE RETOURNER 

CE PRODUIT OÙ VOUS L’AVEZ ACHETÉ.

Pour le service à la clientèle : courriel : [email protected]

pour le service en anglais, composez le  866-661-1218

pour le service en espagnol, composez le  866-661-1218

pour le service en français, composez le  866-374-9203

ARRÊT

ARRÊT

INSTRUCTION MANUAL ENCLOSED

MANUEL D’INSTRUCTION À L’INTÉRIEUR

MANUAL DE INSTRUCCIONES ADJUNTO

INSTRUCTION MANUAL ENCLOSED

MANUEL D’INSTRUCTION À L’INTÉRIEUR

MANUAL DE INSTRUCCIONES ADJUNTO

Summary of Contents for 73702/23WM9083-PM92

Page 1: ...L nea para llamadas en ingl s 866 661 1218 L nea para llamadas en espa ol 866 661 1218 L nea para llamadas en franc s 866 374 9203 STOP STOP PARE PARE ATTENTION SI VOUS AVEZ DES PROBL MES OU QUESTIONS...

Page 2: ...Customer Service Twin Star International Inc Delray Beach FL 33445 Made in China Printed in China Espa ol p 15 TABLE OF CONTENTS Important Information 2 Product Specifications 3 Package Contents 4 Ha...

Page 3: ...ting this fireplace again 10 Do not use outdoors 11 This heater is not intended for use in bathrooms laundry areas and similar indoor locations Never locate this appliance where it may fall into a bat...

Page 4: ...e than 20 ft 6 m in length 23 See directions in Figure 1 This heater is for use on 120 volts The cord has a plug as shown in figure 1 See Figure 1 for grounding instruction An adapter as shown at C is...

Page 5: ...TS Part Description Quantity A Hearth Base 1 B Left Front Panel 1 C Right Front Panel 1 D Center Front Panel 1 E Left Side Panel 1 F Right Side Panel 1 G Mantel Top 1 H Center Top Panel 1 I Insert 1 G...

Page 6: ...els are labeled left and right as viewed from the front of unit WARNING To avoid injury from unexpected starting or electrical shock do not plug the power cord into a source of power during unpacking...

Page 7: ...ASSEMBLY INSTRUCTIONS PREPARATION Before beginning assembly of product make sure all parts are present Compare parts with package contents list and diagram above If any part is missing or damaged do...

Page 8: ...CC into the Hearth Base push the completed assembly from the step 3 to the Hearth Base as show in diagram tighten Screw BB through the pre drilled holes CC F E AA A CC BB Fig 2 2 Screw Camlock AA 1 in...

Page 9: ...o mounting brackets attached to the back of the Left and Right Front panels Set aside with the wood screws PLEASE READ ALL ELECTRIC FIREPLACE INSERT INSTRUCTIONS PRIOR TO INSTALLING ELECTRIC INSERT IN...

Page 10: ...but will hold the settings in the memory By pressing the power button again the unit will turn on at the same settings NOTE Holding the power button on the control panel for 10 seconds will disable t...

Page 11: ...omplies with Canadian ICES 003 REPLACING THE REMOTE CONTROL BATTERY When the remote control stops operating or its range seems reduced it is time to replace the battery with new ones Note Batteries sh...

Page 12: ...ectrical shock and injury to persons WARNING Do not use this fireplace if any part of it has been under water Immediately call a qualified service technician to inspect the fireplace and replace any p...

Page 13: ...gher than the temperature setting Adjust the temperature settings to ensure that the thermostat is set higher than the current room temperature Heater doesn t work but Power and Heater settings are ON...

Page 14: ...ng from defective part s repair replacement or otherwise of same will not be covered by this warranty nor shall the manufacturer assume responsibility for same 6 The owner user assumes all other risks...

Page 15: ...1 1 B Main Circuit Board Y11 C53 P15 1 C Flame Generator Drive Motor Y07 P10Q 1 D Flame Generator Spinner Y10 S52 P011 1 E LCD Display Y10 C43 P70 1 F Front Projection Screen Y10 S52 P09 1 G Flame Cir...

Page 16: ...19 Informaci n De Seguridad 19 Preparaci n 20 Instrucciones De Montaje 20 Instrucciones De Funcionamiento 23 Cuidado Y Mantenimiento 25 Soluci n De Problemas 26 Garant a Limitada De 1 A o 27 Lista De...

Page 17: ...hacer funcionar esta chimenea 10 No lo use en exteriores 11 Este calentador no se debe usar en el ba o lavadero y en espacios h medos similares inte riores Nunca coloque este calentador donde se pueda...

Page 18: ...no debe tener m s de 6 10 m 20 pies de largo 23 Consulte las instrucciones en la Figura 1 Este calentador fue dise ado para su uso en 120 voltios El cable tiene un enchufe como se muestra en la figura...

Page 19: ...Base 1 B Panel Frontal Izquierdo 1 C Panel Frontal Derecho 1 D Panel Frontal Central 1 E Panel Lateral Izquierdo 1 F Panel Lateral Derecho 1 G Chimenea Repisa 1 H Panel Superior Central 1 I Inserto 1...

Page 20: ...erda y derecha vistos desde el frente de la unidad ADVERTENCIA Para evitar lesiones por arranque inesperado o descarga el ctrica no conecte el cable de alimentaci n a una fuente de energ a durante el...

Page 21: ...y atornille la Leva de Bloqueo AA 1 en los agujeros del Panel Frontal Central D Aseg rese de apretar la Leva de Bloqueo AA 1 Empuje el Panel Frontal Iz quierdo B y el Panel Frontal Derecho C ajustado...

Page 22: ...junto completo del paso 3 a la Chimenea Base como se muestra en el diagrama apriete el Tornillo BB a trav s de los agujeros pre perforados CC F E AA A CC BB Fig 2 2 Atornille la Leva de Bloqueo AA 1 e...

Page 23: ...iba al conjunto terminado Utilice un destornillador Phillips para apretar la Leva de Bloqueo AA 2 Herrajes utilizados AA CC Leva de Bloqueo x 6 Clavija de Madera x 6 Instale Inserto desde atr s Soport...

Page 24: ...chimenea consiste en un calentador de ventilaci n forzada con elemento de alambre Existen 11 niveles de termostato a los que puede acceder lo que incluye el ajuste de APAGADO y ENCENDIDO Este bot n d...

Page 25: ...de Canad NOTA OPERE EL TRANSMISOR REMOTO A UN RITMO LENTO MEDIDO PRESIONE LOS BOTONES DEL CONTROL REMOTO CON UNA PRESI N SUAVE Y UN MOVIMIENTO LEVE SI SE PRESIONAN LOS BOTONES REPETIDAMENTE EN UNA SUC...

Page 26: ...n el ctrica o nuevo cableado de esta unidad s lo debe realizarlo un electricista certificado de acuerdo con los c digos nacionales y locales Si se repara o reemplaza cualquier componente el ctrico o...

Page 27: ...que la temperatura configurada Ajuste el ajuste de temperatura para asegurarse de que la tem peratura configurada en el termo stato sea mayor que la tempera tura actual de la habitaci n El calentador...

Page 28: ...tipo que surja de la pieza defectuosa su reparaci n reemplazo u otra situaci n y el fabricante no asume ninguna responsabilidad por las mismas 6 El due o usuario asume todos los riegos si los hay incl...

Page 29: ...incipal Y11 C53 P15 1 C Motor de accionamiento del generador de flamas Y07 P10Q 1 D Generador de flamas disco giratorio Y10 S52 P011 1 E Pantalla LCD Y10 C43 P70 1 F Pantalla de proyecci n frontal Y10...

Page 30: ...L nea para llamadas en ingl s 866 661 1218 L nea para llamadas en espa ol 866 661 1218 L nea para llamadas en franc s 866 374 9203 STOP STOP PARE PARE ATTENTION SI VOUS AVEZ DES PROBL MES OU QUESTIONS...

Reviews: