95
Twin Disc, Incorporated
Troubleshooting
Power Transmission System Operator’s Manual #1020510
TRAN SYS FAULT Message -- TranSol# (1 through 6) Log Code
CIRCUIT Status Code
This fault message will be displayed if the control detects an open circuit to the
appropriate transmission range clutch valve. Computer neutral will be selected,
and the message displayed until the fault is corrected and the control power
cycled by the key switch. The circuit can be checked by removing the J4 cable
and checking the appropriate terminals as identified in the chart that follows.
The proper impedance for each coil is 5 to 11 ohms.
Table 2. Transmission Solenoid Listing
Log
Co de
So lenoid
Energized
Co nnect or
Co ntact s
App roximate
Resistance
Oh ms
T ranSol1
1
J4
J4S1 and J4S2
5 to 11
T ranSol2
2
J4
J4N2 and J4 N3
5 to 11
T ranSol3
3
J4
J4M2 and J4M3
5 to 11
T ranSol4
4
J4
J4L1 and J4L2
5 to 11
T ranSol5
5
J4
J4P1 and J4T1
5 to 11
T ranSol6
6
J3
J3K1 and J3 J3
5 to 11
An intermittent status code may be caused by an intermittent or a
temperature sensitive fault in the valve or the wires between the control
and the valve. Look for any trends in occurrence of the status code,
such as only when transmission oil is cold or hot. Try to check valve and
harnesses immediately after an intermittent code occurs.
Summary of Contents for TA-90-8501
Page 3: ...Document Number 1020510 Revison 1 May 2002 Power Shift Transmission System Operator s Manual ...
Page 4: ......
Page 133: ......
Page 134: ......
Page 135: ......
Page 136: ......
Page 137: ......
Page 138: ......
Page 139: ......
Page 140: ......
Page 141: ......
Page 142: ......
Page 143: ......
Page 144: ......
Page 145: ......
Page 146: ......
Page 147: ......
Page 148: ......
Page 149: ......
Page 150: ......
Page 151: ......