MNL-1RK-SPDR-PWR-V1.0
3
Preparing the Lead
1.
Cut the power lead for your device, with enough length to
reach from your device, to the location of the ONErack Spider
Unit.
2.
Strip the insulation from the ends of the wires and identify
which is positive and which is negative for your 3
rd
party
equipment.
3.
Insert the stripped ends into the power connector. Make sure
that the polarity is correct, as shown, before you tighten the
screws.
4.
Insert the power connector into one of the outputs on the
Power Module.
Risk of damage to equipment
Before you cut any power leads, record the polarity and
voltage for each one with a suitable meter.
Before you connect any rewired DC power connector to
any device, check that the polarity and voltage match
what you recorded before you cut the power lead.
Remove your device’s power lead from the mains supply
before you cut the cable.
Cutting power leads should only be done by competent,
qualified personnel – if in doubt, consult a qualified
electrician.
Summary of Contents for 1RK-SPDR-PWR
Page 2: ......