![TVLogic LVM-181S Operation Manual Download Page 28](http://html.mh-extra.com/html/tvlogic/lvm-181s/lvm-181s_operation-manual_1183377028.webp)
28
05 Menu Operations
[7] WAVEFORM & FOCUS
RANGE ERROR
-
Used to set whether or not to activate [Y MAX], [Y MIN],
[C MAX], [C MIN], [Y PICTURE BLINK] and [C PICTURE
BLINK] functions.
-
The values which are set in [Y MAX], [Y MIN], [C MAX],
[C MIN] menu are indicated on the Waveform set
in [WAVE FORM DISPLAY] menu.
-
If [Y PICTURE BLINK] or [C PICTURE BLINK] is enabled,
the section of image that exceeds the selected values of
[Y MAX], [Y MIN], [C MAX] and [C MIN] shall blink.
-
RANGE ERROR function doesn’t support the RGB signals.
Y MAX
-
Used to set the maximum luma(Y’) level.
-
Available range is from [0] to [254].
-
Pixels with values exceeding the maximum Y’ level blink
in the screen and are displayed in red on the Waveform.
Y MIN
-
Used to set the minimum luma(Y’) level.
-
Available range is from [0] to [254].
-
Pixels with values below the minimum Y’ level blink in
the screen and are displayed in red on the Waveform.
C MAX
-
Used to set the maximum chroma(C’) level.
-
Available range is from [0] to [254].
-
Pixels with values exceeding the maximum C’ level blink
in the screen and are displayed in red on the Waveform.
C MIN
-
Used to set the minimum chroma(C’) level.
-
Available range is from [0] to [254].
-
Pixels with values below the minimum C’ level blink in
the screen and are displayed in red on the Waveform.
Y PICTURE BLINK
-
Used to trigger selections of image that exceed
[Y MAX] and [Y MIN] to blink.
C PICTURE BLINK
-
Used to trigger selections of image that exceed
[C MAX] and [C MIN] to blink.
LVM-181S
Multi Format LCD Monitor