C2-6204 S
ERIES
O
PERATION
M
ANUAL
49
Status
message
Description
Effect
Inactive
HDCP is not active
at the DVI
connector.
HDCP-encrypted material cannot be received
by the unit.
Active
HDCP is active at
the DVI connector.
HDCP-encrypted material can be received by
the unit, but only if a HDCP-compliant display
or device is attached to the unit’s output.
See ‘Adjust outputs’ for a description of how the HDCP system works on your
scaler.
This feature is only present on certain units – it is used with the next menu item to
form a simple ‘EDID Manager’.
EDID is an information packet retrieved by a PC graphic card over a DVI link from a
monitor which tells the graphic card which resolutions the display supports. In the
case of your unit, it tells the graphic card what resolutions are compatible with it –
by emulating a display.
The above menu lets the user select which of 8 EDID data blocks are ‘shown’ to a
PC or other DVI/HDMI source. (It does not affect any other input.) Note that some
graphic cards will usually only read the EDID data when the cable is first connected,
or on power-up.
The 8 EDID blocks are as follows:
EDID
Usage
Mem1
Mem2
Mem3
Mem4
Mem5
Mem6*
User-definable – see ‘EDID capture’
HDMI*
Default HDMI EDID data for your unit
DVI
Default DVI EDID data for your unit
Mon
The attached monitor’s EDID data
*Your unit will have either Mem6 or HDMI, but not both.
If you change this value, you’ll need to store your settings and then re-boot the
CORIO2 unit at least once to ensure that the source sees that the EDID data has
changed.
Source: DVI1
Display emul. EDID [DVI]