C2-6204 S
ERIES
O
PERATION
M
ANUAL
98
15.6
Scaling / sampling / memory
Size and position: automatic via AutoSet or Manual
Image size: 50 user-definable presets (presets 6 to 10 pre-defined)
Image freeze: one video frame
Settings memory: non-Volatile
Zoom range: variable to 10x Zoom (1000%)
Shrink range: variable to 10%
Image mirroring: Horizontal and/or Vertical
Horizontal filtering: full digital
Conversion technology: proprietary
Color resolution: 24-bit RGB (16.8 Million Colors), 20-bit 4:2:2 YCbCr processing.
Sampling rate: 162MHz maximum
Firmware memory: flash, upgradeable via RS-232
15.7
Tally module
Tally inputs detect a connection to ground. Internally pulled to 2.5v through
resistors.
Tally outputs are opto-isolated and pull to ground. Internally pulled to 5v through
4k7 resistor.
5v output supplied, current-limited to 100mA.
RJ45 connector supports RS-485 and RS-422 modes.
UMD protocol supports TSL 3.1 only.
(See Adjust tally menu section.)
15.8
Warranty
See warranty policy for further details.
15.9
Regulatory Compliance
Unit conforms to FCC, CE, RoHS requirements.
15.10
Environmental
Operating Temperature 0° to +50° C (+32° to +122 F)
Operating Humidity 10% to 85%, Non-condensing
Storage Temperature -10° to +70° C (+14° to +158° F)
Storage Humidity 10% to 85%, Non-condensing
15.11
Power Requirement
Mains supply: 100-240V AC (50-60 Hz).
Power consumption ~20W (but varies between units).
15.12
Control Methods
Locally via the front panel buttons and Liquid Crystal Display.
Remotely via the RS-232, RS-422, RS-485 interface using a D9 female connector.
Remotely using Ethernet via a RJ45 Ethernet connector.