![Tuthill TT10P Operation And Safety Manual Download Page 7](http://html.mh-extra.com/html/tuthill/tt10p/tt10p_operation-and-safety-manual_1182610007.webp)
6
6
Table 2: Troubleshooting Guide
Problem
Possible Cause
Solution
Notes
• Dead batteries
• Replace batteries
Seal to electronics is
Meter won't turn on
• Damaged electronics
• Replace the meter
broken if the display is
removed or punctured.
Counter has exceeded
Reset display to zero by
Meter will continue to
Flashing decimals
9999 units
pressing and holding button
operate normally.
2
Flashing BAT Icon
Low batteries
Replace batteries
See battery
replacement section
Leaking fl uid at the
• Need thread sealant
• Add sealant to the joint
inlet / outlet port
• Cross-threaded port
• Replace the meter
Fluid fl ows; meter
• Turbine is jammed
• Flush the meter
won’t count
• Meter failure
• Replace the meter
• Air is in system
• Ensure meter is full of
Meter will count air. Fluid
liquid at all times
viscosities will change
Meter reading is
• Meter is installed backwards • Correct fl ow direction
with temperature
not correct
of the meter
• Fluid viscosity changed
• Wrong CAL/fl uid factor
• Use correct CAL/factor
• Poor calibration
• Recalibrate
• Air is in the system
• Ensure meter is full of
40 mesh minimum inlet
liquid at all times
screen
• Meter is installed backwards • Correct fl ow direction
Meter is not
of the meter
consistent / repeatable • Particulates in the fl uid
• Flush the meter
• Turbine is gummed up
• Put a screen in front of meter
• Operating outside fl ow
• Operate within fl ow range
range of meter
of meter
• Calibration Error
• Recalibrate with a more
Indicates fl uid calibration
accurate container
is out of acceptable
• Meter may have
• Replace the meter
range. Volumetric
Err0
excessive wear
container may not be
accurate or there is air
in the system. Meter may
have excessive wear
Damaged electronics or
• Press and hold button
Software error
2 to reset counter and
Err1
then recalibrate meter
• Replace the meter
Bad eeprom
Replace the meter
Meter still functions but
Err2
totals and calibration
will be lost if batteries
are removed.
Summary of Contents for TT10P
Page 1: ...Operation and Safety Manual TT10P In line Turbine Meter ...
Page 10: ...Manual de operación y seguridad Medidor de turbina en línea TT10P ...
Page 19: ...Manuel d utilisation et de sécurité Compteur à turbine en ligne TT10P ...
Page 28: ...Betriebs und Sicherheitsanleitung TT10P Inline Turbinenradzähler ...