14
5. OPERATION
WARNING
Do not operate without guards in place.
WARNING
Maximum operating speed: Table 1 states the maximum operating speed in
RPM (rotations per minute), the maximum pressure differential, maximum
vacuum and maximum temperature rise. Do not exceed these limits.
WARNING
Physical harm may occur if human body parts are in contact or exposed to
the process pressures or vacuum. Assure that all connections are protected
from human contact.
WARNING
If rated pressure or vacuum levels are exceeded, process fluids will migrate
to other parts of the blower and system.
CAUTION
Do not touch hot surfaces.The upper limit of the blower operation is 445º F
(229º C). Do not touch the blower while it is in operation and assure blower
is cool when not in operation.
CAUTION
Do not stop the blower if there are high outlet pressures in the outlet piping.
Unload the outlet piping prior to shutting down the blower.
CAUTION
Hearing protection is required while the blower is in operation. Noise levels
may exceed 75 dBA.
NOTE
The upper limits are not intended for continuous operation. Consult with
factory for detailed information assistance.