30
09
Troubleshooting
Manual 4804 Rev C p/n 004804 0000
SYMPTOM
PROBABLE CAUSE
REMEDIES
Excessive vibration
Coupling misaligned
Align.
Pump not properly
anchored
Anchor.
See excessive noise
Check inlet pressure and gas
À
ow.
Motor overloaded
Excessive back
pressure
Reduce height of pump discharge.
Too much sealant
liquid
See Table 3-1 on page 11
for proper
À
ow rate.
Misalignment
Realign motor and pump.
Defective bearing
Replace bearing.
Abnormal bearing wear
Misaligned pump
assembly
Impeller binding or will
not turn
Accumulation of rust or
scale
See Operation on page 14
and
Maintenance on
page 17
.
Foreign object in pump
Dismantle pump and remove foreign object.
Summary of Contents for KLRC Series
Page 6: ...iv Table of Contents Manual 4804 Rev C p n 004804 0000 ...
Page 33: ...27 08 Reassembly Manual 4804 Rev C p n 004804 0000 Figure 8 2 Bearing Driver Tool ...
Page 34: ...28 08 Reassembly Manual 4804 Rev C p n 004804 0000 Figure 8 3 Foot Alignment Tool ...
Page 37: ...31 09 Troubleshooting Manual 4804 Rev C p n 004804 0000 NOTES ...