Maintenance
Manual 4804 Rev C p/n 004804 0000
PREPARATION FOR STORAGE
If the pump is to be idle for an extended period of
time, it should be preserved internally to prevent
rust if the sealant liquid is water or water-soluble
liquids. The pump can be preserved temporarily
(2 to 3 months) by adding a water-soluble rust
inhibitor into the pump. For longer periods of
preservation, drain the pump by removing the drain
plugs. When the draining is completed and all drain
plugs have been replaced,
¿
ll the pump to 1/3 to
1/4 full using Shell Oil Company, VSI, SAE-25
(SAE-33 or SAE-37 can be used) or antifreeze.
Rotate the pump by hand to coat the interior of the
pump with oil.
Table 5-1
Disassembly
Assembly
NDE Shaft seal
replacement
NDE Stage only
1
1 + 2
7
6 + 7
DE Shaft seal
replacement
DE Stage only
3
3 + 4
4
2 + 3
Total Disassembly
1 - 5
1 - 8
SPARE PARTS
The assembly drawings and parts lists beginning
on page 32
are cross-section views of the
pumps represented in this manual. A set of
recommended spare parts for each pump model
operating should be available as initial spare
parts. When ordering parts, the pump nameplate
information must accompany the order along with
the part reference number and name.
Summary of Contents for KLRC Series
Page 6: ...iv Table of Contents Manual 4804 Rev C p n 004804 0000 ...
Page 33: ...27 08 Reassembly Manual 4804 Rev C p n 004804 0000 Figure 8 2 Bearing Driver Tool ...
Page 34: ...28 08 Reassembly Manual 4804 Rev C p n 004804 0000 Figure 8 3 Foot Alignment Tool ...
Page 37: ...31 09 Troubleshooting Manual 4804 Rev C p n 004804 0000 NOTES ...