3
Heater Models and Parts List
Part
Number
Maximum
Wattage
Maximum
Volts
Maximum
Amperage
Minimum Flow
SCFH (SLPM)
F068462
1500
120
13
60 (28)
F068463
2000
240
9
F068464
3500
240
15
F070878
2000
240
9
F071383
3500
240
9
F075145
3500
240
15
Specifications
Maximum Inlet Pressure
60 PSI (4 BAR)
Minimum Inlet Pressure
0.3 PSI (20mBAR)
Maximum Inlet Air Temperature
120°F (50°C)
Maximum Exit Air Temperature
1400°F (760°C)
(see page 6 for Performance Curves)
Minimum Airflow
60 SCFH (28 SLPM)
UL File #
E177292
(only for those Part #s listed above; otherwise contact factory)
General Information
Environmental Conditions:
Ambient Temperature
32°F to 104°F (0°C to 40°C)
Humidity
0% to 95% R.H.
Ventilation:
Use in a well-ventilated area away from excess dust, dirt, and moisture.
Cleaning:
With unit OFF and unplugged, exterior surfaces may be wiped clean using a dry, lint-free cloth.
Protective Earthing:
Each heater comes with a convenient grounding stud and hardware located at the inlet of the heater for
protective means of earthing.
Summary of Contents for F068462